Only show results available in Virginia? Ok

emissions testing analysis Applications

  • Premium

    Gas analysis & monitoring system for emission monitoring

    From the environmental point of view, an issue is any solid, liquid or gaseous substance introduced into the atmosphere that can cause air pollution. Given the wide variety of substances present in the atmosphere, have been proposed several methods of classification: Primary pollutants can be of gaseous or particulate.

    By ETG Risorse e Tecnologia based in Montiglio, ITALY.

  • Premium

    Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring

    The Series 8900 Hydrogen Sulfide and Carbon Disulfide Analyzer provides direct measurement of H2S and CS2 in ambient air. This instrument is utilized for continuous emission monitoring. The Series 8900 H2S and CS2 Analyzer employs a Photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the H2S, CS2, and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. H2S and CS2 are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Gravimetric analysis for soil consultancy

    There are many businesses that release emissions into the air due to their daily processes. Because there are regulations in place to minimize pollution, these businesses need the help of air testing companies to make sure they are in compliance with the regulations. We perform air emissions testing to let your business know whether it falls within the set guidelines, as well as emissions monitoring services to ensure you remain within the regulations. This will keep the environment around your plant healthy and ensure you don’t accrue fines for violations.

    By Custom Stack Analysis, LLC. based in Alliance, OHIO (USA).

  • Air monitoring for laboratories

    Many of the air quality analyses can be performed with standard laboratory consumables, such as traditional filter papers. However, some analyses require materials with specific features, for example filters with low metal levels.

    Common air monitoring applications include:

    • Air quality testing of ambient environment and emissions. Includes particulate monitoring methods such as PM2.5 and PM10, and chemical analysis such as heavy metals determination.
    • Asbestos sampling and analysis

    By GE Healthcare UK Limited based in Little Chalfont, UNITED KINGDOM.

  • Premium

    PTR-TOFMS systems for Flux Measurement of BVOCs

    The ultra-fast analysis capabilities of IONICON PTR-TOF instruments are essential for eddy covariance flux measurements, allowing to study deposition and emission rates of biogenic volatile organic compounds (BVOCs).

    By Ionicon Analytik Ges.m.b.H. based in Innsbruck, AUSTRIA.

  • Premium

    Measurement solution for soil chamber gas flux

    Closed chamber gas flux measurements can be made with Protea FTIR analysers to allow researchers in the field of atmospheric gas analysis from agricultural and livestock to measure evolved gases such as N2O, CO2, CO, NH3, and CH4. Nitrous oxide (N2O) and Methane (CH4) emissions from soil, plant and livestock are especially important gases to measure, given their high potential as greenhouse gases (GHGs). NH3, whilst not a greenhouse gas on the scale of N2O, CH4 and CO2, is a major emission from agricultural, such as after the spreading of liquid manure, and steps are required to measure and reduce the NH3 emissions and the effects they have on the ecosystem.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Measurement solution for to multi-stream by-pass system

    A large pharmaceutical plant runs a Thermal Oxidiser on plant to incinerate their solvent-containing gas streams before emission. When the oxidiser is offline, then the plant must monitor the release of solvent to the atmosphere. A ProtIR 204C fixed monitoring system was installed that continually measures 24 plant solvents, including Acetone, Cyclohexane, DCM, DMF, IPA, MIBK, Toluene and THF. Given the high levels that are possible, the system has an active dilution system, reducing the concentration of the measured gas in the analyser to levels that can be analysed simply. Chemometric modelling enables interferences from the overlapping absorption spectra to be accounted for, ensuring accurate analysis of all 24 gases.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Ambient air monitoring by FID detection – airmoVOC BTEX

    Urban pollution is a problem that concerns more and more people in charge of public health. In large cities, car emissions are an important source of atmospheric pollution. This problem is growing as the traffic keeps on increasing. BTEX compounds are present in car emissions. It is therefore important to be able to analyze them with short analysis cycle duration and on a continuous and automatic way.

    By Chromatotec Group based in Val de Virvée, FRANCE.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you