    Gas monitoring instruments and systems for engine emissions measurements

    The exhaust gas from combustion engines is a complex mixture of gases and particulate matter. The composition of the gas may change rapidly. Multicomponent analysis of exhaust gases can be performed with a Gasmet™ FTIR Gas Analyzer with a response time (T90) of one second. The winning combination is the result using of a small volume gas sample cell, a powerful sample pump and a fast detector with liquid nitrogen cooling. The analyzer, sampling system and computer can be assembled on a cart for use in a...

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Process monitoring solutions for NH3 truck engine monitoring

    A new EC regulation states that  diesel engines need to have active cleaning with urea injection in order to reduce NOx emissions. In order to control the urea dosage, a reliable measurement system is required. OPSIS LD500 laser diode gas analyser for monitoring ammonia (NH3), has been tested and approved by German TÜV, in accordance with the EURO VI standard.

    By Opsis AB based in Furulund, SWEDEN.

  • Wireless industrial I/O applications for the oil and gas Industry

    Banner Engineering`s SureCross product line offers reliable wireless industrial I/O monitoring and control solutions for most applications, including these examples of wireless installations for the oil and gas industry.

    By Banner Engineering Corp. based in Minneapolis, MINNESOTA (USA).

  • Measurement solution for formaldehyde FTIR measurement

    Reciprocating internal combustion engines burning natural gas are a source of formaldehyde emissions. There are strict tolerances imposed on operators of engines to ensure that formaldehyde is removed effectively and that formaldehyde emissions are below published limits. The only instrumental method for formaldehyde monitoring is FTIR, following procedures such as US EPA Method 320 and Environment Agency TGN M22. Protea’s FTIR gas analysers have been specifically designed to follow these methods and our...

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    High quality gas sensor solutions for landfill

    State-of-the-art systems enabling easy monitoring of CO2 and CH4 gases. Capped Landfill Sites produce a range of gases, mostly methane and carbon dioxide. Legislation requires that these gases are safely removed from beneath the cap to avoid a physical explosion due to the build-up of pressure beneath the cap. Safe disposal usually entails burning such as flare stacks, internal combustion engines or by processing to produce Methane gas fuel. For large sites with access to power distribution infrastructure...

    By Edinburgh Sensors Ltd based in Livingston, UNITED KINGDOM.

  • Saran Bag application

    Title : Preliminary Sampling Methodology and Analytical Procedures for Ambient Sulfur Hexafluoride, Corporate Author : ARMY MEDICAL ENVIRONMENTAL ENGINEERING RESEARCH UNIT EDGEWOOD ARSENAL MD Personal Author(s) : Luckan,Susan K. ; Cooper,William J. Report Date : JAN 1973 Pagination or Media Count : 23 Abstract : A preliminary evaluation of techniques of sampling and gas chromatographic analysis for low levels of sulfur hexafluoride was conducted to determine the most feasible method for available equipment....

    By Analytical Specialties, Inc. based in Elburn, ILLINOIS (USA).

  • Cetane Number of Diesel Fuels #3010

    The Cetane number of a diesel fuel is a measure of the ignition properties and is an important specification that must be met during fuel production. The traditional laboratory method for Cetane number determination is the knock engine method in which the fuel is burned and its combustion characteristics compared to known standards. This method is time and labor intensive, and provides no ability for real time control of production. This note discusses the use of Guided Wave hardware and software tools for the...

    By Guided Wave, Inc. based in Rancho Cordova, CALIFORNIA (USA).

  • Octane Number of Gasoline using NIR Spectroscopy #3012

    When every second counts and performance is on the line Guided Wave's NIR analyzers allow for easy measurement of octane numbers in gasoline and refinery production units using fiber optic -based, near-infrared (NIR) spectroscopy. *Fast and reliable measurement of the octane number of gasoline (RON & MON). * Control gasoline production in real-time directly with in process monitoring. * Certify gasoline meets specification before release. *Gain significant improvements in process control. *Minimize the need for...

    By Guided Wave, Inc. based in Rancho Cordova, CALIFORNIA (USA).

  • Premium

    PTR-TOFMS systems for automotive real-time vehicle exhaust analysis

    Monitoring exhaust gas from combustion engines, emitting a large number of different compounds and with rapidly changing concentrations due to variations in operating conditions, necessitates an instrument that measures in real-time and with high sensitivity – an IONICON PTR-TOFMS.

    By Ionicon Analytik Ges.m.b.H. based in Innsbruck, AUSTRIA.

  • Premium

    Process control for the petrochemical chemical industry

    Most chemical products as we know today are composed of a few hundreds of basic chemicals, extracted mostly from crude oil and natural gas. Instrumentation, analyzer systems and process optimization are not new to the operation of all chemical and petrochemical processes. However, tightening regulations, competition pressure and increasing raw materials cost urges the industry to go deeper into process control technology. As a single-source supplier of the (petro)chemical industry since many years, AppliTek...

    By AppliTek NV based in Nazareth, BELGIUM.

  • Laboratory analysis for environmental consulting

    Ormantine USA works closely with consultants, engineers, and other environmental professionals on a daily basis to help find the best solutions to meet individual needs. Ormantine air and soil samplers can be used in: Remediation Performance; Soil Gas Monitoring; Site Assessments; Brownfield Redevelopment; Landfill / Waste Management; Decontamination; Hazardous Material Investigations; Emission Monitoring & Testing; Exposure...

    By Ormantine USA Ltd., Inc. based in Palm Bay, FLORIDA (USA).