Only show results available in Virginia? Ok

environment monitoring analyzer Applications

  • Combustion gas analysis for the indoor environment industry

    Flue-gas analyzers are designed to be rugged and accurate at the same time. They are used by the HVAC industry, energy industry, process control, glass industry, food industry, universities and analysis is required. 

    By IMR Environmental Equipment, Inc. based in St. Petersburg, FLORIDA (USA).

  • Continuous Emissions Monitoring Calibration Systems (CEMCS)

    The Environics Series Continuous Emissions Monitoring Calibration Systems (CEMCS) have been used in CEM vans and laboratories for over twenty years. They meet or exceed the performance requirements of the United States EPA 40 CFR Part 51 Method 205 Appendix M. Our systems are custom built, computerized, mass flow controller based gas calibration systems which allow you to dilute a single high concentration cylinder of span gas to low levels for the calibration of gas analyzers.

    By Environics, Inc. based in Tolland, CONNECTICUT (USA).

  • Premium

    HCl Monitoring in Air

    Hydrogen chloride (HCl) is a colorless, sometimes slightly yellow, gas. It is an undesired environmental component that may be damaging to workers and the surroundings. Exposure limits have thus been established by industries to make sure that the workers operate in a safe environment. HCl monitoring is especially required for incinerators, coal-fired power plants, aluminum recycling and cement plants. Unisearch offers a reliable and easy-to-use HCl analyzer – the TDLAS-based LasIR system. Studies have shown that TDLAS equipment provides data that is more accurate than conventional gas monitoring equipment. When calibrated for HCl monitoring, TDLAS is able to detect this gas among other gases present in the area and provide continuous updates with regards to the changes in its concentration.

    By Unisearch Associates Inc. based in Concord, ONTARIO (CANADA).

  • Premium

    Monitoring of mercury in ambient air

    Mercury, being widespread in environment, has toxic effect on a human organism even at a low concentration. Therefore, quantitativ e determination of mercury in vari ous environments is one of the most important environmental monitoring problems. The use of a mercury analyzer RA-915M/RA-915+/RA- 915Light with Zeeman background correction provides di rect real-time continuous determination of mercury in air from 0.5 ng/m 3 within the overall possible range of me rcury concentration in ambient air.

    By Lumex Instruments Group based in Mission, BRITISH COLUMBIA (CANADA).

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to fixe or mobile ambient air quality monitoring laboratories. The VOC72M is fitted with a PID detector new generation, much more sensitive, more stable and whose lamp does not need to be cleaned; the analyzer integrates flow control fittings a 3 levels security system built on and uses only one gas (nitrogen). This robust and low maintenance instrument performs all the functions (sampling, analysis and data management) in a simple and completely autonomous mode. It is a particular

    By Environnement S.A based in Poissy, FRANCE.

  • Premium

    Testing Fume Hood Flow Dynamics using SF6 as a Tracer Gas

    A safe laboratory environment requires an effective method for clearing toxic material from fume hoods. Since all handling of toxic materials is completed in these hoods, it is critical to have a procedure to evaluate their operation to assure adequate protection for laboratory workers. The InfraRan Specific Vapor Analyzer, factory calibrated for SF6, is an ideal instrument for measuring fume hood efficiency in accordance with ASHRAE and other standards. Manufacturers identify the flow dynamics (factors that affect air flow in the hood and performance with air) using the ratings AM (as manufactured), AI (as installed), and AU (as used). A fume hood evaluation conducted under its operational environment is critical, as these tests will indicate any installation shortcomings as well as direct workers in proper laboratory hood techniques.

    By Spectro Scientific based in Chelmsford, MASSACHUSETTS (USA).

  • Ambient Monitor Gas Calibration with Ozone Generators

    EnvironicsĀ® Ambient Monitor Calibrator with Ozone Generators facilitate dynamic calibration of ambient air analyzers. These instruments automatically perform zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, O3, hydrocarbons and other gases of interest. All ozone generators are factory calibrated using a NIST traceable ozone standard. The Series 6100, Series 6103 and Series 9100 all meet or exceed U.S. Environmental Protection Agency requirements.

    By Environics, Inc. based in Tolland, CONNECTICUT (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you