Only show results available in Virginia? Ok

environmental monitoring instrumention Applications

  • Sediment Pollution Instruments

    Our SediMeter instruments are designed with sediment pollution monitoring in mind. They form part of a system with network and software components designed specifically to be the best possible sediment pollution monitoring system.

    By Lindorm, Inc. based in Medley, FLORIDA (USA).

  • Premium

    Sound Instrumentation for Environmental Noise Monitoring

    State of the art noise monitoring systems; Modern noise monitoring systems offer a wide range of advanced features and come with software that can analyze and structure long term measurements data efficiently.  A complete noise monitoring system consists of one or more noise monitoring terminals, a noise server and work stations for presentation, post processing and reporting.

    By Norsonic AS based in Lierskogen, NORWAY.

  • Environmental Noise Monitoring

    The XL2 Sound Level Meter provides the dedicated solution for monitoring environmental noise in industry and communities. It measures levels and detailed spectral information in parallel and stores the data on an SD card for post-processing and reporting. A linear audio file (wav-file) may be recorded for detailed simultaneous analysis. The type approved class 1 sound level meter offers a flexible handheld instrument with accurate and reliable measurements. Data recording can be scheduled to occur at pre-determined times or automatically triggered when pre-determined levels are exceeded. Applications: Unattended noise monitoring stations (mobile or fixed installations) Annoyance assessment of noise according to ISO 1996-2 Construction noise measurements meeting the Section 61 notice (UK) Urban noise monitoring and noise mapping according to directive 2002/49/EC Verifying boundary noise level emission Advantages Handheld and compact design for field applications and stand-alone oper

    By NTi Audio AG based in Schaan, LIECHTENSTEIN.

  • Environmental monitoring solution for fertilizer plants

    Measurement of particulates, SO2, NOX, ammonia, fluorides and greenhouse gas emissions from the fertilizer industry requires careful selection of instruments. Ecotech offers a complete monitoring solution tailored to this industry.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Premium

    Determination of TOC in stack

    PROBLEM: The industrial chimney's emissions of Volatile Organic Compounds (VOCs) are becoming issues of global importance and to have an accurate knowledge about how to test VOC turns into a strategic issue. VOC emissions are quantified and monitored according to standard EN 12619, using FID analyser which uses hydrogen and other reference gases in pressurized cylinder. Operators must then approach the sampling point, often placed several meters from the ground, climbing chimneys of industrial settlements with instruments and cylinders. Is it possible making this job easier and safer? SOLUTION: Using the Polaris FID analyser produced by Pollution Srl, Italy, it is possible to carry out the VOCs monitoring according to EN 12619 without lifting accessories and heavy weights typically involved with FID analyser. Polaris FID analyser complies with this standard regulation but what is really a breakthrough and cutting-edge, is the unmatched portability and the next generation technology

    By Pollution Srl based in Budrio, ITALY.

  • Premium

    Measuring aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    The Series 8900 BTEX Analyzer provides direct measurement of Benzene, Toluene, Ethylbenzene, and Xylenes in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites. The Series 8900 BTEX Analyzer employs a photoionization detector (PID) as the sensing element. This detector is specific to volatile organic compounds. The Benzene, Toluene, Ethylbenzene, and Xylene`s in the gas sample are physically separated using proprietary GC columns.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Core Analysis for unconventional reservoirs

    Low field Nuclear Magnetic Resonance (NMR) is routinely used in core analysis laboratories to examine the T2 relaxation time distribution of fluids in core plugs. These distributions can be interpreted to give information on: pore size distributions; permeability; total and effective porosity; free fluid index and bound water volumes. The partnership between Oxford Instruments and Green Imaging Technologies allows us to integrate hardware and software to enable any core analysis laboratory to generate these petrophysical results without the need for in-depth knowledge of NMR.

    By Oxford Instruments plc based in Abingdon, UNITED KINGDOM.

  • Premium

    PTR-TOFMS systems for Flux Measurement of BVOCs

    The ultra-fast analysis capabilities of IONICON PTR-TOF instruments are essential for eddy covariance flux measurements, allowing to study deposition and emission rates of biogenic volatile organic compounds (BVOCs).

    By Ionicon Analytik Ges.m.b.H. based in Innsbruck, AUSTRIA.

  • Environmental monitoring solution for mineral processing

    Measurement of particulates, SO2, NOX, CO, hydrocarbons and greenhouse gas emissions from the mineral process industries requires careful selection of instrumentation. Ecotech offers a complete monitoring solution tailored to this industry.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Environmental monitoring solution for pulp & paper

    Measurement of particulates, SO2, NOX, TRS and greenhouse gas emissions from the Pulp & Paper industry requires careful selection of instrumentation. Ecotech offers a complete monitoring solution tailored to this industry.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Environmental monitoring solution for glass manufacturing areas

    Heavy metals, particulates, SO2 & NOx are the main emissions from the glass manufacturing industry and their measurement requires careful selection of instrumentation. Ecotech offers a complete monitoring solution tailored to this industry.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Environmental monitoring solution for aluminium industry

    Measurement of particulates, SO2, NOx, fluorides and greenhouse gas emissions from the aluminium industry requires careful selection of instrumentation. Ecotech offers a complete monitoring solution tailored to this industry.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Filtration for Flue Gas Analysis and CEMS

    Three Steps of CEMS: 1st Step: Gas Sampling 2nd Step: Gas conditioning and treatment 3rd Step: Measurement/Calibration In first step, the function is to get sample gas and forward to 2nd step for treatment. During this step, it cannot block the probes and cannot result condensation of moisture. So a filter online back flushing should be equipped in this part. The filters to be used: 1, Filter is used to ensure the stability of system and reduce the maintenance 2, Filtration Grade: usually 2 or 3 micron 3, Temp. is around 0-180 deg C 4, Back flushing gas is heated, impulse flushing 5, Filter Material: Titanium Sintered, SS316L Sintered, PTFE sintered, Ceramic Membrane and so on 2nd Step Gas Treatment: #11;The coarse filters and the liquid particle filters The coarse and fine cartridge can filter the small particles in the gas and acid aerosol things to better protect the instruments. The micron can be 0.1micron, filtration rate can be up to 99.99%, two layers can be 99.9999%

    By Shanghai CMI Environmental Technology Co.,Ltd. based in Shanghai , CHINA.

  • Premium

    Gas monitoring instruments and systems for stack testing according to EPA test method 320

    The United States Environmental Protection Agency (EPA) has two stack testing methods for FTIR gas analyzers. Method 320 is an FTIR method for measuring wide range of organic and inorganic pollutants. Method 321 is a specific version for measuring hydrogen chloride HCl at cement kilns producing Portland cement. These methods define a quality assurance and control processes for verifying the accuracy of the results. The requirements for analytical equipment and software are defined on 40 CFR Part 60 Appendix B Performance Specification 15. Gasmet™ Gas Analyzers and Calcmet™ software have been designed to take the requirements of the performance specification into account.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to fixe or mobile ambient air quality monitoring laboratories. The VOC72M is fitted with a PID detector new generation, much more sensitive, more stable and whose lamp does not need to be cleaned; the analyzer integrates flow control fittings a 3 levels security system built on and uses only one gas (nitrogen). This robust and low maintenance instrument performs all the functions (sampling, analysis and data management) in a simple and completely autonomous mode. It is a particular

    By Environnement S.A based in Poissy, FRANCE.

  • Environmental monitoring solution for cement industry

    Measurement of particulates, SO2, NOx, hydrocarbons and greenhouse gas emissions from the cement manufacturing industry requires careful selection of instrumentation. Ecotech offers a complete monitoring solution tailored to this industry.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Environmental monitoring solution for sulfuric acid plants

    Measurement of SO2, sulfuric acid mist and greenhouse gas emissions from sulfuric acid plants requires careful selection of instrumentation. Ecotech offers a complete monitoring solution tailored to this industry.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • calibration gas

    calibration gas , British specialty gases company, with a local North Africa presence. We can supply you with high quality gas mixtures for a wide range of applications including Environmental Monitoring, Gas Detection, Mud Logging, Laser Cutting, and Laboratory Analysis. Our gas mixtures are used in the Oil, Gas and Petrochemical industries Our main focus is to give our customers gravimetrically produced, high precision calibration gas mixtures conforming to ISO 6142, along with a range of high purity gases and pressure control equipment, used for instrumental analysis and gas detection applications. AG Gases' senior management have many years experience in the European and International markets and now offer this knowledge to benefit Egyptian and North African customers.

    By AG Gases Ltd based in Stoke-on-Trent, UNITED KINGDOM.

  • Premium

    Low level measurement of aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring.

    The Series 8900 BTEX Analyzer with a high-sensitivity PID provides direct low level measurement of Benzene, Toluene, Ethylbenzene, and Xylene`s in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Flow meters for analytical flow solutions

    Gas mass flow controllers are widely used in gas chromatographs in order to control carrier gases and to precision purge these instruments. Our instruments also find use in custom gas mixing and blending systems for environmental research.

    By Sierra Instruments, Inc. based in Monterey, CALIFORNIA (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you