Only show results available in Virginia? Ok

exhaust gas emissions Applications

  • Exhaust Gas Emissions

    Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas/vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, & include a range of special sampling, vacuum pumping & vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, & thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR studies, Hiden gas analysis systems include enhanced pumping for hydrogen and special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour & CH4 in the PPM to 100% concentration range provides vital ininformation for process development and process monitoring...

    By Hiden Analytical Ltd. based in Warrington, UNITED KINGDOM.

  • Premium

    Gas monitoring instruments and systems for engine emissions measurements

    The exhaust gas from combustion engines is a complex mixture of gases and particulate matter. The composition of the gas may change rapidly. Multicomponent analysis of exhaust gases can be performed with a Gasmet™ FTIR Gas Analyzer with a response time (T90) of one second. The winning combination is the result using of a small volume gas sample cell, a powerful sample pump and a fast detector with liquid nitrogen cooling. The analyzer, sampling system and computer can be assembled on a cart for use in a dynamometer laboratory, or the portable version can be used for roadside tests.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Emission control & air dedusting for fuel oil boilers

    For PM emission control in high temperature exhaust streams, such as fuel oil boilers, usual dedusters such as bag filters are very maintenance demanding. Particularly, diesel and fuel particulates are very sticky and clog to filter elements, unless protection reagents are used. Flue gas cooling is also needed in front of the filter when temperatures are higher than 200 ºC. On the other hand, regular cyclones and multicyclones are frequently not able to reduce emissions to present emission limits.

    By Advanced Cyclone Systems, S. A. based in Porto, PORTUGAL.

  • Continuous Emissions Monitoring

    Requirements for monitoring emissions to air are governed by EU/UK legislation and are implemented in the form of a permit by the Environment Agency or local authority. The Dr Foedisch muti-component gas analysers continuously extract a gas sample from the exhaust stream via a stack probe into the analyser cabinet. Both hot and cold gas systems are available, please contact us to discuss which system best suits your requirements.

    By CEM Solutions (UK) Ltd. based in Darley Dale, UNITED KINGDOM.

  • Marine And Offshore Emissions Monitoring & Analysis

    The need to demonstrate environmental responsibility is key for today’s marine and offshore industries. Fuels and exhaust gas emissions are subject to international, regional and national controls and Charterers, as well as the public, demand high standards of performance and reliability.

    By Procal - Parker Hannifin Corp based in Peterborough, UNITED KINGDOM.

  • PLAZKAT systems for treatment of emissions in the petrochemical industry

    Today, the reduction of atmospheric emissions produced by the gas processing and petrochemical industries is an acute problem. The most widely used technique of exhaust gas treatment comprises complete burning, even though this method does not provide an adequate degree of treatment. Therefore, in this case PLAZKAT systems are a more effective solution for removing aromatic hydrocarbon from the emissions.

    By Plasma Air Systems Corporation based in Harju Maakond, ESTONIA.

  • Emission control & air dedusting for steel and ferrous alloys

    teel and ferrous alloys production happens in industrial manufacturing processes which involve high temperature exhaust streams, often at more than 900 ºC. Typically, the gas flows into a gas conditioning tower to cool down to approximately 200 ºC, before entering into an ESP. These flue gases from steel or ferrous alloys kilns are also very maintenance demanding for bag filters and the very small size of the particles limit the use of usual dedusters such as regular cyclones and multicyclones as pre-separators. Bag filter failure is consequently a very common problem for clients in this industry. Client`s needs include a very robust dedusting system, either serving as end-stage collector avoiding the need to cool down flue gases, or strongly minimizing the loads of aggressive material to bag filters. 

    By Advanced Cyclone Systems, S. A. based in Porto, PORTUGAL.

  • Premium

    Gas monitoring instruments and systems for semiconductor manufacturing

    In the semiconductor manufacturing industry, various perfluorinated compounds (PFCs) are used. The emissions of the PFC compounds into the ambient air are reduced by scrubbing of the exhaust gases from the process. In this process, the Gasmet™ FTIR Gas Analyzers can be used to measure the emissions into the atmosphere and also monitor the efficiency of the scrubbers. Typically monitored PFCs in the exhaust gas include carbon tetrafluoride CF4, trifluoromethane CHF3, and hexafluoroethane C2F6.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Gas detection analyzers for pollution control

    Government and environmental groups are forcing industries with medium to high VOC exhausts to reduce emissions by as much as 98%. Incineration using pollution control devices such as oxidizers and flare stacks is one way to bring the exhaust emissions in line with the regulations. Capturing and reusing solvent in a solvent recovery system is another way.

    By Control Instruments Corporation based in Fairfield, NEW JERSEY (USA).

  • Premium

    Chemiluminescense based analyzer for automotive applications

    Car emissions have to follow more stringent rules: You will find exactly the right instrument for your application! Analyzers for hot, moist, or cold, dry sample gas, and including simultaneous measurement of NO, NO2 and NOx reading AK protocol. ECO PHYSICS offers a unique range of nitric oxide analyzers for the automotive and related industries, supporting the AK protocol. Whether for hot, moist, raw exhaust gas, or bag measurement, you will find exactly the right instrument for your NO, NO2 and NOx application.

    By ECO PHYSICS AG based in Duernten, SWITZERLAND.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you