FID analyzer Applications

  • Premium

    Ambient air monitoring by FID detection – airmoVOC BTEX

    Urban pollution is a problem that concerns more and more people in charge of public health. In large cities, car emissions are an important source of atmospheric pollution. This problem is growing as the traffic keeps on increasing. BTEX compounds are present in car emissions. It is therefore important to be able to analyze them with short analysis cycle duration and on a continuous and automatic way.

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

    The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

    The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Online monitoring solutions for the determination of chlorinated organics in water

    Determining chlorinated organics in waste water of the oxychlorination process is for reasons of environmental compliance. The on-line analyzer system uses a scrubber system where a carrier flow is bubbling through the water. The vapor phase is measured by a Flame Ionization Detector (FID) and is a measure for chlorinated organics of the water.

    By AppliTek NV based in Nazareth, BELGIUM.