Only show results available in Virginia? Ok

fixed gas monitor Applications

  • Premium

    Single Gas Monitoring - Fixed in-situ Duct Path

    Application: Measurements of single gas species through a fixed in-situ duct path. Example: Monitoring NH3 emissions in coal fired power generating stations.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Premium

    Portable and fixed gas analysers for medical gas monitoring

    Geotech supports the monitoring of medical gases within dentistry, hospital and veterinary industries with hand held N2O, O2, CO2 and CO analysers.

    By Geotech based in Leamington Spa, UNITED KINGDOM.

  • Premium

    Portable and fixed gas analysers for CO2 monitoring

    Monitoring industrial processes, CO2 gas quality control and indoor air quality can all be achieved using Geotech`s wide ranging CO2 analysers.

    By Geotech based in Leamington Spa, UNITED KINGDOM.

  • Premium

    Portable and fixed gas analysers for landfill perimeter monitoring

    Controlling potentially explosive and asphyxiate gases from escaping off site is important for meeting Health and Safety standards and protecting the local environment.

    By Geotech based in Leamington Spa, UNITED KINGDOM.

  • Premium

    Portable and fixed gas analysers for incubator verification

    Geotech manufactures and supplies portable carbon dioxide monitors for use in incubator laboratories to verify CO2 in IVF and stem cell research applications.

    By Geotech based in Leamington Spa, UNITED KINGDOM.

  • Premium

    Single Gas Monitoring - Open Path Monitoring

    Application: measurements of single gas species through a fixed open air sample path. Example: HF leak detection in refinery HF Alkylation units.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Premium

    Gas Detection

    Gas Detection is our core business, whether portable, colormetric, fixed systems or Hazmat. We do more than get you the equipment you need--we also help you select it, calibrate it, service it and maintain it. Our technicians, our sales reps and top management can speak with authority on the capabilities of our equipment and match it to your specific application. And we are the champions of the one-of-a-kind solution, because we have the know-how and the right tools.

    By Argus-Hazco based in Chesterfield, MICHIGAN (USA).

  • Premium

    Gas monitoring instruments and systems for process NOx measurement

    Nitric acid HNO3 is an important intermediate reagent for production of several important end products, such as fertilizers, explosives, dyestuffs/pigments, pesticides, pharmaceuticals, photographic materials, plastics, and synthetic fibers. At nitric acid manufacturing plants, the Gasmet™ FTIR Gas Analyzer can be used to measure several gaseous components from the process stream for purposes of process control. A single system can be used to measure the high levels of nitrogen monoxide NO and nitrogen dioxide NO2, as well as water vapor H2O, nitrous oxide N2O, carbon monoxide CO, carbon dioxide CO2 and ammonia NH3. The fixed installation products for these purposes are the Gasmet™ CEM II measurement system, and the Gasmet™ FCX Gas Analyzers, both of which utilize the FTIR measurement technique for simultaneous multicomponent analysis of the sample gas.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to fixe or mobile ambient air quality monitoring laboratories. The VOC72M is fitted with a PID detector new generation, much more sensitive, more stable and whose lamp does not need to be cleaned; the analyzer integrates flow control fittings a 3 levels security system built on and uses only one gas (nitrogen). This robust and low maintenance instrument performs all the functions (sampling, analysis and data management) in a simple and completely autonomous mode. It is a particular

    By Environnement S.A based in Poissy, FRANCE.

  • Premium

    Measurement of acetaldehyde, methanol, & benzene in CO2 applications for gas manufacturers & food & beverage industry

    The BevAlert Model 8900 provides direct measurement of Acetaldehyde, Methanol, and Benzene (AMB) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace impurities in CO2 used in carbonated beverages. The BevAlert Model 8900 employs a photoionization detector (PID). The AMB in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and heavier gases. At sample injection, a fixed volume of sample is carried through the pre-cut column. The backflush is timed so that primarily the AMB and other similar compounds continue on to the analytical column. Contaminants are then backflushed to vent. Acetaldehyde, Methanol, and Benzene are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement solution for siloxane analysis

    Protea can offer online siloxanes analysis using our atmosFIR gas analysers. This allows the real time measurement of siloxanes on plant. We can offer portable siloxanes analysers or fixed siloxane measurement systems.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Gas Detection Solutions for Gold Refining

    Hydrogen Cyanide (HCN) is a highly toxic compound that is a byproduct of many industrial processes. Existing HCN point sensors are maintenance intensive, slow to respond and provide limited coverage. Many HCN sensors do not work reliably in hot or cold weather, or in humid environments. Our technology can be used for fixed monitoring applications or for temporary protection of workers during construction projects.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Premium

    Measurement solution for to multi-stream by-pass system

    A large pharmaceutical plant runs a Thermal Oxidiser on plant to incinerate their solvent-containing gas streams before emission. When the oxidiser is offline, then the plant must monitor the release of solvent to the atmosphere. A ProtIR 204C fixed monitoring system was installed that continually measures 24 plant solvents, including Acetone, Cyclohexane, DCM, DMF, IPA, MIBK, Toluene and THF. Given the high levels that are possible, the system has an active dilution system, reducing the concentration of the measured gas in the analyser to levels that can be analysed simply. Chemometric modelling enables interferences from the overlapping absorption spectra to be accounted for, ensuring accurate analysis of all 24 gases.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Measurement of methane, methanol and ethanol for the biomass monitoring for biofuels.

    The Series 8900 provides direct measurement of methane, methanol, and ethanol for the biofuel industry. The Series 8900 GC employs a flame ionization detector (FID). The methane, methanol, and ethanol in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and heavier gases. At sample injection, a fixed volume of sample is carried through the pre-cut column. The backflush is timed so that primarily the MME and other similar compounds continue on to the analytical column. Contaminants are then backflushed to vent. Methane, methanol, and ethanol are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you