flame ionization monitoring Applications

  • Premium

    Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

    The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Formaldehyde and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Formaldehyde is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

    The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Acrylonitrile and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Acrylonitrile is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of methane, methanol and ethanol for the biomass monitoring for biofuels.

    The Series 8900 provides direct measurement of methane, methanol, and ethanol for the biofuel industry. The Series 8900 GC employs a flame ionization detector (FID). The methane, methanol, and ethanol in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and heavier gases. At sample injection, a fixed volume of sample is carried through the pre-cut column. The backflush is timed so that primarily the MME and other similar compounds continue on to the analytical column. Contaminants are then backflushed to vent. Methane, methanol, and ethanol are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).