Only show results available in Virginia? Ok

formaldehyde testing Applications

  • Premium

    Measurement solution for formaldehyde FTIR measurement

    Reciprocating internal combustion engines burning natural gas are a source of formaldehyde emissions. There are strict tolerances imposed on operators of engines to ensure that formaldehyde is removed effectively and that formaldehyde emissions are below published limits. The only instrumental method for formaldehyde monitoring is FTIR, following procedures such as US EPA Method 320 and Environment Agency TGN M22. Protea’s FTIR gas analysers have been specifically designed to follow these methods and our FTIR analyser have been proven in formaldehyde emission measurements over many years.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Measurement solution for accurate continuous formaldehyde measurement formaldehyde in emissions and ambient air applications

    Formaldehyde (HCHO) is the simplest aldehyde species and is present, or generated by, many sources (both natural and industrial). It is classed as a substance that is toxic and harmful to human health.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

    The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Formaldehyde and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Formaldehyde is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Formaldehyde and Acetaldehyde Determination in Air Using Fully Automated On-Line Desorption and Analysis of DNPH Cartridges

    Airborne aldehydes and ketones are collected by passing air through a cartridge containing 2,4-dinitrophenylhydrazine (DNPH). Carbonyl compounds react with the DNPH to form hydrazones, which are immobilized on the cartridge. These compounds can be easily eluted from the cartridge with acetonitrile and analyzed by HPLC with UV detection. Traditionally, this analysis including the workup contains a series of manual steps, which can become time-consuming and could incur experimental error. Automating the extraction of LpDNPH S10 cartridges and putting it in-line with the HPLC analysis will significantly reduce manual labor using this technique and this will improve reproducibility of the method by reducing potential experimental errors by the operator. The automation and unattended operation of the method leads to high throughput for determining airborne formaldehyde and acetaldehyde.

    By Sigma-Aldrich Co., LLC based in Bellefonte, PENNSYLVANIA (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you