ftir method Applications

  • Measurement solution for formaldehyde FTIR measurement

    Reciprocating internal combustion engines burning natural gas are a source of formaldehyde emissions. There are strict tolerances imposed on operators of engines to ensure that formaldehyde is removed effectively and that formaldehyde emissions are below published limits. The only instrumental method for formaldehyde monitoring is FTIR, following procedures such as US EPA Method 320 and Environment Agency TGN M22. Protea’s FTIR gas analysers have been specifically designed to follow these methods and our FTIR analyser have been proven in formaldehyde emission measurements over many years.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Measurement solution for measuring total VOC via FTIR

    Current Total VOC Measurements

    The most common, and current standard, method for measuring Total Volatile Organic Compounds (VOC) is the use of a Flamed Ionisation Detector (FID). This gives a representative value of the total carbon content of a gas stream, as the FID cannot tell which specific organic compounds are present.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Measurement solution for total VOC via FTIR

    Total Volatile Organic Compounds (VOCs) is a common measurement required from industrial emissions. Commonly, a single measurement value is obtained through the use of a Flame Ionisation Detection (FID) analyser. The pyrolysis of the gas stream in a FID analyser allows it to make a measurement of the carbon content of the gas stream. FID analyser cannot indicate the relative abundances of different organic species in a gas stream and often have widely different responses for different gases. However, they are taken as the standard reference method for Total VOC emission measurements.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Gas monitoring instruments and systems for stack testing according to EPA test method 320

    The United States Environmental Protection Agency (EPA) has two stack testing methods for FTIR gas analyzers. Method 320 is an FTIR method for measuring wide range of organic and inorganic pollutants. Method 321 is a specific version for measuring hydrogen chloride HCl at cement kilns producing Portland cement. These methods define a quality assurance and control processes for verifying the accuracy of the results. The requirements for analytical equipment and software are defined on 40 CFR Part 60 Appendix B Performance Specification 15. Gasmet™ Gas Analyzers and Calcmet™ software have been designed to take the requirements of the performance specification into account.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.