Only show results available in Virginia? Ok

gas air monitor Applications

  • Gas Detection

    By MRU Instruments, Inc. based in Houston, TEXAS (USA).

  • Gas Detection

    Gas Detection is our core business, whether portable, colormetric, fixed systems or Hazmat. We do more than get you the equipment you need--we also help you select it, calibrate it, service it and maintain it. Our technicians, our sales reps and top management can speak with authority on the capabilities of our equipment and match it to your specific application. And we are the champions of the one-of-a-kind solution, because we have the know-how and the right tools.

    By Argus-Hazco based in Chesterfield, MICHIGAN (USA).

  • Premium

    Monitoring solutions for the gas analysers areas

    Most large coal fired power plants and combustion processes are required to monitor CO, NO and NO2 (NOx), SO2 and possibly CO2; in addition the analyser has to be normalised to Standard conditions. For this application CODEL offers the five channel GCEM 40 series which uses Infrared absorption to measure these gases plus moisture, pressure and temperature.  The analyser can be configured for single channel operation to monitor any of these gases plus CH4 and HCl.

    By Codel International Ltd based in Bakewell, UNITED KINGDOM.

  • Gas Detection Solutions for GHG Monitoring

    Most sources of fugitive emissions are from multiple points rather than single point sources. So, open path area or perimeter monitoring provides more meaningful fugitive emissions data than an array of point sensors or a program of grab sampling. Point measurements may underestimate emissions because of missing locations with high gas concentrations, or conversely overestimate because they are located in areas of high concentrations. Grab sampling programs typically check only a small percentage of potential leak locations and extrapolate results to an entire facility. Wide margins of uncertainty are associated with such extrapolations. Open path monitoring provides continuously updated, real-time, integrated emissions across a facility boundary.This provides a complete picture of the fugitive emissions across that boundary,enabling identification of specific operations and times that give rise to higher emissions, and so enabling these emissions to be properly managed and controlled.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Chromatography gas analysis for air test

    By Buck Scientific Inc based in East Norwalk, CONNECTICUT (USA).

  • Single Gas Monitoring - Open Path Monitoring

    Application: measurements of single gas species through a fixed open air sample path. Example: HF leak detection in refinery HF Alkylation units.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Premium

    Raw-gas monitoring for scrubber optimizing

    The consumption of scrubbing material in a scrubber is related to the mass flow of acid gases. Hydrogen chloride (HCl) and sulphur dioxide (SO2) are the major acid gases in an incinerator. By measuring the mass flow of SO2 and HCl in the raw gas going into the scrubber, it is possible to calculate the required quantity of scrubbing material.

    By Opsis AB based in Furulund, SWEDEN.

  • Single Gas Monitoring - Fixed in-situ Duct Path

    Application: Measurements of single gas species through a fixed in-situ duct path. Example: Monitoring NH3 emissions in coal fired power generating stations.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • High technology gas generators for air monitoring industry

    Air Monitoring Industry.

    By Leman Instruments SAS based in Archamps, FRANCE.

  • Gas analysis & monitoring systems for dust

    Particulate matter, suspended particulate matter, atmospheric dust, particulate matter, total suspended particulate (TSP), are terms that commonly identify the group of substances suspended in the air (fibers, carbon particles, metals, silica, polluting liquid or solid). Particulate matter is the pollutant that is now considered the greatest impact in urban areas, and is composed of all those solid and liquid particles dispersed in the atmosphere, with a diameter ranging from a few nanometers to 500 microns and above (ie billionths of a meter to half a millimeter).

    By ETG Risorse e Tecnologia S.r.l. based in Montiglio, ITALY.

  • CH4 Monitoring in Air

    CH4 (Methane) is a colorless, odorless natural gas that is used in a wide variety of industrial applications such as power generation and chemical production. It is also a byproduct of many biological and geological processes, fracking, and gas drilling. It is highly flammable and creates amounts of carbon monoxide as its combustion byproduct. Methane needs constant monitoring in waste water treatment (for co-generation) and to ensure proper process control (e.g. to determine burning efficiency). A quality CH4 analyzer that is able to provide continuous monitoring is a perfect solution for this.

    By Unisearch Associates Inc. based in Concord, ONTARIO (CANADA).

  • Premium

    Perimeter Ambient Air Monitoring

    Cerex Multi-Gas Open Path Analyzers are available in both FTIR and UVDOAS technologies to meet specific requirements for perimeter ambient air quality monitoring, leak detection, fugitive emissions monitoring and ambient air quality monitoring. Cerex multi-gas analyzers offer significant advantages over single gas analyzer arrays, electro-chemical sensor arrays and time integrated air sampling hardware

    By Cerex Monitoring Solutions, LLC. based in Atlanta, GEORGIA (US) (USA).

  • O2 Monitoring in Air

    Oxygen (O2) is a colorless odorless gas, essential to all life on Earth but damaging in high concentrations. An O2 analyzer should thus be employed for safety management and air pollution prevention purposes. LasIR MP110 is perfect for continuous emission monitoring of O2. It is based on TDLAS technology and can be calibrated as an O2 analyzer, providing accurate and reliable measurements. It quickly responds to changes in compound concentration, thus providing continuous emission monitoring for the specified gas.

    By Unisearch Associates Inc. based in Concord, ONTARIO (CANADA).

  • Ambient Monitor Gas Calibration with Ozone Generators

    EnvironicsĀ® Ambient Monitor Calibrator with Ozone Generators facilitate dynamic calibration of ambient air analyzers. These instruments automatically perform zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, O3, hydrocarbons and other gases of interest. All ozone generators are factory calibrated using a NIST traceable ozone standard. The Series 6100, Series 6103 and Series 9100 all meet or exceed U.S. Environmental Protection Agency requirements.

    By Environics, Inc. based in Tolland, CONNECTICUT (USA).

  • Gas Detection Solutions for Liquified Natural Gas Detection

    Liquefied natural gas owners require improved routine monitoring of facilities for safety, economic and regulatory reasons. Leaking LNG can cause explosions leading to loss of life and property. Loss of product through undetected leaks dramatically reduces a pipeline operator’s profitability. Traditional gas detectors are slow to reach and require a labour intensive process to keep maintained. IR detectors have been used but with limited success because of cross interference from other atmospheric gases.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Premium

    Gas monitoring instruments and systems for process NOx measurement

    Nitric acid HNO3 is an important intermediate reagent for production of several important end products, such as fertilizers, explosives, dyestuffs/pigments, pesticides, pharmaceuticals, photographic materials, plastics, and synthetic fibers. At nitric acid manufacturing plants, the Gasmet™ FTIR Gas Analyzer can be used to measure several gaseous components from the process stream for purposes of process control. A single system can be used to measure the high levels of nitrogen monoxide NO and nitrogen dioxide NO2, as well as water vapor H2O, nitrous oxide N2O, carbon monoxide CO, carbon dioxide CO2 and ammonia NH3. The fixed installation products for these purposes are the Gasmet™ CEM II measurement system, and the Gasmet™ FCX Gas Analyzers, both of which utilize the FTIR measurement technique for simultaneous multicomponent analysis of the sample gas.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Portable and fixed gas analysers for CO2 monitoring

    Monitoring industrial processes, CO2 gas quality control and indoor air quality can all be achieved using Geotech`s wide ranging CO2 analysers.

    By Geotech based in Leamington Spa, UNITED KINGDOM.

  • Premium

    Monitoring solutions for the flow monitoring areas

    Many large combustion plants are now required to monitor mass emissions of major pollutants and to do so requires an accurate measurement of stack gas velocity. The VCEM 5100 is certified to EN 15267 part 3 QAL 1 for all industrial processes including waste incineration. It has several key advantages, firstly the sensors optics are not in contact with the hot and dusty environment, the VCEM 5100 can monitor gases at temperatures exceeding 10000C and the analyser requires minimal maintenance. The VCEM 5100 can be used in extremely dust environments such as SCR’s when dust loadings exceed 10g/m3. The VCEM 5100 is in full compliance with EN/ISO 16911 part 2.

    By Codel International Ltd based in Bakewell, UNITED KINGDOM.

  • Premium

    Benzene Monitoring

    Cerex Monitoring Solutions manufactures UVDOAS analyzers for a variety of Benzene monitoring applications. As benzene specific single gas or multi-gas analyzers, our instruments are available with application specific detection ranges and fully configurable alarm functionality.

    By Cerex Monitoring Solutions, LLC. based in Atlanta, GEORGIA (US) (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you