  • Premium

    Gas monitoring instruments and systems for process NOx measurement

    Nitric acid HNO3 is an important intermediate reagent for production of several important end products, such as fertilizers, explosives, dyestuffs/pigments, pesticides, pharmaceuticals, photographic materials, plastics, and synthetic fibers. At nitric acid manufacturing plants, the Gasmet™ FTIR Gas Analyzer can be used to measure several gaseous components from the process stream for purposes of process control. A single system can be used to measure the high levels of nitrogen monoxide NO and nitrogen dioxide NO2, as well as water vapor H2O, nitrous oxide N2O, carbon monoxide CO, carbon dioxide CO2 and ammonia NH3. The fixed installation products for these purposes are the Gasmet™ CEM II measurement system, and the Gasmet™ FCX Gas Analyzers, both of which utilize the FTIR measurement technique for simultaneous multicomponent analysis of the sample gas.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Gas monitoring instruments and systems for engine emissions measurements

    The exhaust gas from combustion engines is a complex mixture of gases and particulate matter. The composition of the gas may change rapidly. Multicomponent analysis of exhaust gases can be performed with a Gasmet™ FTIR Gas Analyzer with a response time (T90) of one second. The winning combination is the result using of a small volume gas sample cell, a powerful sample pump and a fast detector with liquid nitrogen cooling. The analyzer, sampling system and computer can be assembled on a cart for use in a dynamometer laboratory, or the portable version can be used for roadside tests.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Filtration for Flue Gas Analysis and CEMS

    Three Steps of CEMS: 1st Step: Gas Sampling 2nd Step: Gas conditioning and treatment 3rd Step: Measurement/Calibration In first step, the function is to get sample gas and forward to 2nd step for treatment. During this step, it cannot block the probes and cannot result condensation of moisture. So a filter online back flushing should be equipped in this part. The filters to be used: 1, Filter is used to ensure the stability of system and reduce the maintenance 2, Filtration Grade: usually 2 or 3 micron 3, Temp. is around 0-180 deg C 4, Back flushing gas is heated, impulse flushing 5, Filter Material: Titanium Sintered, SS316L Sintered, PTFE sintered, Ceramic Membrane and so on 2nd Step Gas Treatment: #11;The coarse filters and the liquid particle filters The coarse and fine cartridge can filter the small particles in the gas and acid aerosol things to better protect the instruments. The micron can be 0.1micron, filtration rate can be up to 99.99%, two layers can be 99.9999%

    By Shanghai CMI Environmental Technology Co.,Ltd. based in Shanghai , CHINA.

  • Premium

    Mass flow devices for analytical instrumentation

    Axetris mass flow devices are used in a variety of analytical applications: Gas Chromatography, Mass Spectrometry, Atomic Spectroscopy, Elemental Analysis, Thermal Analysis, Bioreactor and Fermentor.

    By Axetris Ag based in Kaegiswil, SWITZERLAND.

  • calibration gas

    calibration gas , British specialty gases company, with a local North Africa presence. We can supply you with high quality gas mixtures for a wide range of applications including Environmental Monitoring, Gas Detection, Mud Logging, Laser Cutting, and Laboratory Analysis. Our gas mixtures are used in the Oil, Gas and Petrochemical industries Our main focus is to give our customers gravimetrically produced, high precision calibration gas mixtures conforming to ISO 6142, along with a range of high purity gases and pressure control equipment, used for instrumental analysis and gas detection applications. AG Gases' senior management have many years experience in the European and International markets and now offer this knowledge to benefit Egyptian and North African customers.

    By AG Gases Ltd based in Stoke-on-Trent, UNITED KINGDOM.

  • Chemical Industry Emissions Analysis

    The inherent flexibility of Procal analysers enables the instruments to be configured to meet Customer’s specific requirements. Their capability to monitor gas concentrations at elevated pressures and temperatures make Procal products ideal for process applications in the Chemical Industry.

    By Procal - Parker Hannifin Corp based in Peterborough, UNITED KINGDOM.

  • Thermal Analysis Mass Spectrometry

    Hiden offers optimized interface coupling to a range of thermal analysis systems including: TGA-MS and TGA/DTA-MS systems: Hiden Isochema IGA - intelligent gravimetric analyser, PerkinElmer-TA Instruments- Netzsch- Mettler Toledo- Seteram Calorimetry: Mass spectrometry for simultaneous evolved gas/calirometry analysis. Evolved gas analysis compliments the calorimetric data providing reaction kinetics data and speciation of reaction off gas. Solid Insertion Probe: An integrated solid insertion probe mass spectrometer system for in-situ TPD studies. Hiden Catlab: An integrated microreactor/mass spectrometer for catalyst characterisation.

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Premium

    Measurement of acetaldehyde, methanol, & benzene in CO2 applications for gas manufacturers & food & beverage industry

    The BevAlert Model 8900 provides direct measurement of Acetaldehyde, Methanol, and Benzene (AMB) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace impurities in CO2 used in carbonated beverages. The BevAlert Model 8900 employs a photoionization detector (PID). The AMB in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and heavier gases. At sample injection, a fixed volume of sample is carried through the pre-cut column. The backflush is timed so that primarily the AMB and other similar compounds continue on to the analytical column. Contaminants are then backflushed to vent. Acetaldehyde, Methanol, and Benzene are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    PTR-TOFMS systems for automotive real-time vehicle exhaust analysis

    Monitoring exhaust gas from combustion engines, emitting a large number of different compounds and with rapidly changing concentrations due to variations in operating conditions, necessitates an instrument that measures in real-time and with high sensitivity – an IONICON PTR-TOFMS.

    By Ionicon Analytik Ges.m.b.H. based in Innsbruck, AUSTRIA.

  • Premium

    Measurement solution for VOC emissions monitoring

    Protea has used our VOC gas analysers in many projects requiring the monitoring of complex mixes of VOCs. In the chemical and pharmaceutical industry, VOC abatement plants such as scrubbers and carbon-bed systems are typical installations where the use of Protea analysers and our VOC analysis expertise have proved valuable to plant operators. They prove a very powerful and flexible tool in both process gas measurements and VOC emissions monitoring. In the laboratory, Protea can deliver instruments with all the chemometric software and support to enable users to measure hundreds of gases.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Measurement solution for fire testing for the railway industry

    A lot of research is carried out in laboratory and on real fires as to the gaseous substances produced in fire effluent. Measurement principles using analytical instrumentation are becoming more widely used in fire testing, due to the quick, real-time nature of the measurements. ISO 19702 is an international standard developed for the use of FTIR analysers in the analysis of gas from fire effluents. Further to this, local test standards such as DIN 5510, applicable to the railway industry, can provide further requirements for gases to be measured.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to fixe or mobile ambient air quality monitoring laboratories. The VOC72M is fitted with a PID detector new generation, much more sensitive, more stable and whose lamp does not need to be cleaned; the analyzer integrates flow control fittings a 3 levels security system built on and uses only one gas (nitrogen). This robust and low maintenance instrument performs all the functions (sampling, analysis and data management) in a simple and completely autonomous mode. It is a particular

    By Environnement S.A based in Poissy, FRANCE.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you