Only show results available in Virginia? Ok

gas chromatographer Applications

  • Alkane (hydrocarbon) gas measurement for mudlogging in oil & gas drilling rigs

    The need for operator and maintainance intensive gas chromatograph (GC) analyzers was eliminated. Customer can now deploy all-optical, unattended sensor system for monitoring the composition of hydrocarbon gases (C1-C5) exiting the well bore which provides crucial information about the drilling formation that would save time and money.

    By MKS Instruments, Inc. based in Andover, MASSACHUSETTS (USA).

  • Premium

    Gas analyzers and detectors for the ethanol processing

    Gas chromatographs and hydrocarbon analyzers can be key in adding value to the ethanol production process and protecting the environment from Volatile Organic Compound (VOC)emissions created during the process.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement solution for FTIR Vs. GC in gas analysis

    Comparison of Technologies

    A gas chromatograph (GC) has traditionally been the technology of choice for laboratory analysis of gas samples. GCs have been used for over 50 years in the qualification and quantification of complex mixtures of gases. The techniques and methodology required to run GCs are often a pre-requisite for any laboratory technician. Recent developments in Fourier Transform Infra-Red (FTIR) gas analysis has enabled this technology to start to replace GCs in the lab.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Flow meters for analytical flow solutions

    Gas mass flow controllers are widely used in gas chromatographs in order to control carrier gases and to precision purge these instruments. Our instruments also find use in custom gas mixing and blending systems for environmental research.

    By Sierra Instruments, Inc. based in Monterey, CALIFORNIA (USA).

  • Premium

    Flow meters for the general research flow solutions

    Our instruments are widely used by original equipment manufacturers of gas chromatographs, mixing and blending systems and other pieces of analytical equipment. The mulitple gas capability and wide choice of flow controlllers-for high pressure, very low flows and corrosive gases-offer customers excellent application flexibility.

    By Sierra Instruments, Inc. based in Monterey, CALIFORNIA (USA).

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to fixe or mobile ambient air quality monitoring laboratories. The VOC72M is fitted with a PID detector new generation, much more sensitive, more stable and whose lamp does not need to be cleaned; the analyzer integrates flow control fittings a 3 levels security system built on and uses only one gas (nitrogen). This robust and low maintenance instrument performs all the functions (sampling, analysis and data management) in a simple and completely autonomous mode. It is a particular

    By Environnement S.A based in Poissy, FRANCE.

  • Saran Bag application

    Title : Preliminary Sampling Methodology and Analytical Procedures for Ambient Sulfur Hexafluoride, Corporate Author : ARMY MEDICAL ENVIRONMENTAL ENGINEERING RESEARCH UNIT EDGEWOOD ARSENAL MD Personal Author(s) : Luckan,Susan K. ; Cooper,William J. Report Date : JAN 1973 Pagination or Media Count : 23 Abstract : A preliminary evaluation of techniques of sampling and gas chromatographic analysis for low levels of sulfur hexafluoride was conducted to determine the most feasible method for available equipment. Using a Tracor MT-150 gas chromatograph equipped with Nickel 63 electron capture detector and polarized dc voltable, it was possible to detect sulfur hexafluoride at a concentration of 0.06 ppb with a 5A molecular sieve column and nitrogen carrier gas, without preconcentration of the sample. Also, a comparison of glass and Saran sampling materials proved that no detectable loss of the tracer gas resulted with the Saran bags (between 6 ppm and 0.06 ppb SF6

    By Analytical Specialties, Inc. based in Elburn, ILLINOIS (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you