Only show results available in Virginia? Ok

gas chromatography Applications

  • Gas chromatography for laboratories

    By F-DGSi based in Evry Cedex, FRANCE.

  • Chromatography gas analysis for air test

    By Buck Scientific Inc based in East Norwalk, CONNECTICUT (USA).

  • Chromatography systems for environmental monitoring

    With the growth of contamination generated from agricultural and industrial production, it causes a threat to the enviroment including drinking water, atmosphere and soil. The chemists have always seeked out the effective analytical methods to detect and identify chemical contaminants. Dikma provides innovative products and application solutions according to government regulations and industry standards, for air and water quality monitoring, gas detection.

    By Dikma Technologies Inc. based in Lake Forest, CALIFORNIA (USA).

  • Premium

    Measurement of C1-C5 hydrocarbons for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed sample volume is carried to the pre-cut column. Backflush of the pre-cut column is timed from sample injection so that only C1-C5 hydrocarbons are eluted from the pre-cut column to the analytical column. C6+ hydrocarbons on the pre-cut column are then vented. C1-C5 hydrocarbons are separated on the analytical column and elute to the flame ionization detector (FID) for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of C1-C5 with carbon dioxide for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons and Carbon Dioxide required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed sample volume is carried to the pre-cut column. Backflush of the pre-cut column is timed from sample injection so that only C1-C5 hydrocarbons are eluted from the pre-cut column to the analytical column. C6+ hydrocarbons on the pre-cut column are then vented. Then a third column is used in conjunction with a second 10-port valve for individual analysis of methane. C1-C5 hydrocarbons are separated on the analytical column and elute to the flame ionization detector (FID) for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Percent Aromatics in Gasoline #3008

    The aromatic content of gasoline determines many of its combustion properties. Since it also impacts the environmental characteristics of the fuel it is desirable to have accurate measurements of this parameter. The traditional analytical method for measuring aromatics is either gas chromatography (GC) or an older method entitled fluorescent indicator adsorption (FIA), both of which are time and labor intensive. This note will discuss the use of Guided Wave hardware and software tools for the measurement of % aromatics in fuel products using fiber optic-based, Near-Infrared (NIR) spectroscopy. NIR can be applied in real time directly in process monitoring or as a laboratory procedure. In either case NIR is a time and money saving alternative to traditional methods. Request Application Note #3008

    By Guided Wave Inc, based in Rancho Cordova, CALIFORNIA (USA).

  • Premium

    Fast C1 to C5 - PetroAlert Series 9100

    The PetroAlert® Series 9100 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing a 30 second analysis of C1-C5 hydrocarbons required in Mud Logging for Oil & Gas exploration, while maintaining C1-C2 separation at 200:1 concentration ratios.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Mass flow devices for analytical instrumentation

    Axetris mass flow devices are used in a variety of analytical applications: Gas Chromatography, Mass Spectrometry, Atomic Spectroscopy, Elemental Analysis, Thermal Analysis, Bioreactor and Fermentor.

    By Axetris Ag based in Kaegiswil, SWITZERLAND.

  • Premium

    Analysis of VOC compounds in water by Purge & Trap or dynamic headspace

    Context & Challenges Volatile organic compounds (VOC) can be dissolved in water. Sometimes water is polluted and to study contamination of VOC in finished drinking water, VOC must be measured. Chromatotec® Solutions Chromatotec® has developed a specific system for the measurement of VOC in water: a Purge & Trap system, the airmoPURGE. The analyzer is coupled with a degasing system allowing the extraction of dissolved gases. The complete system is based on: - 502.2 method from US EPA – “Volatile organic compounds in water by purge and trap capillary column gas chromatography with photoionization and electrolytic conductivity detectors in series – Revision 2.1”. - 524.2 method from US EPA – “Measurement of purgeable organic compounds in water by capillary column gas chromatography/mass spectrometry – Revision 4.0”.

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    Measurement of ethylene oxide for monitoring workplace exposure limits

    The Series 8900 Ethylene Oxide Analyzer combines the selectivity of gas chromatography with the sensitivity of a Photoionization Detector (PID) providing interference free response to Ethylene Oxide (EtO) at levels below 0.05 ppm. This analytical method is referenced in OSHA`s `Occupational Exposure to Ethylene Oxide: Final Standard` 29 CFR Part 1910. The system documents exposure levels including: time-weighted averages (TWA), short-term exposure limits (STEL) and instantaneous alarms. Areas that are typically monitored include; EtO Sources - gas storage areas, sterilizer doors, aeration doors, and the General Work Area - decontamination, packaging and preparation and sterile product storage areas.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Analysis of Herbicides in Drinking Water

    Herbicides are used throughout the world to combat the growth of unwanted plant life. These polar compounds are hydrophilic, so they may find their way into drinking water sources. While gas chromatography has historically been the preferred technique for analysis of herbicides in water samples, the use of LC-MS/MS for this application is gaining acceptance. This is due to the power of MS/MS to provide detailed identification of multiple analytes, but also in part due to the variety of HPLC stationary phases that are available. In particular, several HPLC phases are available that provide great retention and peak shapes for polar analytes, such as herbicides, even under mostly aqueous mobile phase conditions. The combination of these factors may possibly eliminate need for time-consuming sample preparation.

    By Sigma-Aldrich Co., LLC based in Bellefonte, PENNSYLVANIA (USA).

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to fixe or mobile ambient air quality monitoring laboratories. The VOC72M is fitted with a PID detector new generation, much more sensitive, more stable and whose lamp does not need to be cleaned; the analyzer integrates flow control fittings a 3 levels security system built on and uses only one gas (nitrogen). This robust and low maintenance instrument performs all the functions (sampling, analysis and data management) in a simple and completely autonomous mode. It is a particular

    By Environnement S.A based in Poissy, FRANCE.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you