Only show results available in Virginia? Ok

gas detector Applications

  • Premium

    Gas analyzers and detectors for the ethanol processing

    Gas chromatographs and hydrocarbon analyzers can be key in adding value to the ethanol production process and protecting the environment from Volatile Organic Compound (VOC)emissions created during the process.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of C1-C5 hydrocarbons for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed sample volume is carried to the pre-cut column. Backflush of the pre-cut column is timed from sample injection so that only C1-C5 hydrocarbons are eluted from the pre-cut column to the analytical column. C6+ hydrocarbons on the pre-cut column are then vented. C1-C5 hydrocarbons are separated on the analytical column and elute to the flame ionization detector (FID) for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of acetaldehyde, methanol, & benzene in CO2 applications for gas manufacturers & food & beverage industry

    The BevAlert Model 8900 provides direct measurement of Acetaldehyde, Methanol, and Benzene (AMB) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace impurities in CO2 used in carbonated beverages. The BevAlert Model 8900 employs a photoionization detector (PID). The AMB in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and heavier gases. At sample injection, a fixed volume of sample is carried through the pre-cut column. The backflush is timed so that primarily the AMB and other similar compounds continue on to the analytical column. Contaminants are then backflushed to vent. Acetaldehyde, Methanol, and Benzene are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Gas Detection Solutions for Liquified Natural Gas Detection

    Liquefied natural gas owners require improved routine monitoring of facilities for safety, economic and regulatory reasons. Leaking LNG can cause explosions leading to loss of life and property. Loss of product through undetected leaks dramatically reduces a pipeline operator’s profitability. Traditional gas detectors are slow to reach and require a labour intensive process to keep maintained. IR detectors have been used but with limited success because of cross interference from other atmospheric gases.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Premium

    Measurement of C1-C5 with carbon dioxide for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons and Carbon Dioxide required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed sample volume is carried to the pre-cut column. Backflush of the pre-cut column is timed from sample injection so that only C1-C5 hydrocarbons are eluted from the pre-cut column to the analytical column. C6+ hydrocarbons on the pre-cut column are then vented. Then a third column is used in conjunction with a second 10-port valve for individual analysis of methane. C1-C5 hydrocarbons are separated on the analytical column and elute to the flame ionization detector (FID) for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    CO gas monitoring for coal pulverising mills

    Our range of safety analysers can offer early detection of fire / explosive conditions. From CO monitors for pulverising coal mills through to UV flame and smoke detectors installed on oil rigs and the cross-channel passenger shuttles, operated by Eurotunnel.

    By Codel International Ltd based in Bakewell, UNITED KINGDOM.

  • Premium

    Gas monitoring instruments and systems for engine emissions measurements

    The exhaust gas from combustion engines is a complex mixture of gases and particulate matter. The composition of the gas may change rapidly. Multicomponent analysis of exhaust gases can be performed with a Gasmet™ FTIR Gas Analyzer with a response time (T90) of one second. The winning combination is the result using of a small volume gas sample cell, a powerful sample pump and a fast detector with liquid nitrogen cooling. The analyzer, sampling system and computer can be assembled on a cart for use in a dynamometer laboratory, or the portable version can be used for roadside tests.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    High quality gas sensor solutions for biogas

    Fast, accurate and reliable measurement of CO2 and CH4 concentration. Methane and CO2 concentration measurements are a key part of the evaluation of the anaerobic digestion process. Too high or too low gas concentration levels can indicate a change in the efficiency of the fermentation process. AD process control systems measure the Methane content (and often the CO2 content) of the gas stream to control or evaluate the AD process and warn of problems. Edinburgh Sensors provide high performance OEM gas detectors that are able to give fast, accurate and reliable measurements of both CO2 and Methane concentrations.

    By Edinburgh Instruments Ltd based in Livingston, UNITED KINGDOM.

  • Premium

    Measurement solution for measuring total VOC via FTIR

    Current Total VOC Measurements

    The most common, and current standard, method for measuring Total Volatile Organic Compounds (VOC) is the use of a Flamed Ionisation Detector (FID). This gives a representative value of the total carbon content of a gas stream, as the FID cannot tell which specific organic compounds are present.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Fast C1 to C5 - PetroAlert Series 9100

    The PetroAlert® Series 9100 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing a 30 second analysis of C1-C5 hydrocarbons required in Mud Logging for Oil & Gas exploration, while maintaining C1-C2 separation at 200:1 concentration ratios.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measuring aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    The Series 8900 BTEX Analyzer provides direct measurement of Benzene, Toluene, Ethylbenzene, and Xylenes in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites. The Series 8900 BTEX Analyzer employs a photoionization detector (PID) as the sensing element. This detector is specific to volatile organic compounds. The Benzene, Toluene, Ethylbenzene, and Xylene`s in the gas sample are physically separated using proprietary GC columns.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    SF6 Leak Detection

    Monitoring Sulfur Hexafluoride (SF6) in the Power Utility Industry. Monitoring Sulfur Hexafluoride in the Power Utility Industry The SF6 Leak Detector 3434i from LumaSense offers an unmatched combination of performance and convenience. Based on the company’s Photoacoustic Spectroscopy (PAS) technology, the system offers highly accurate, reliable and stable quantitative gas analysis and detection. The growing environmental requirements and pressures regarding the use of SF6 make LumaSense’s system a coveted tool designed for everyday use. The system is able to measure the total concentration of the SF6 gas in an enclosed area, where the switchgear (or other SF6 filled equipment) is tested. Although only the total amount leaked is required by today’s standards, it is also advantageous to be able to pin point the leaks. This makes it easier to improve the integrity of the equipment. The SF6 Leak Detector system meets all of requirements for confined area such as substation Monitoring.

    By LumaSense Technologies, Inc. based in Santa Clara, CALIFORNIA (USA).

  • Premium

    Analysis of VOC compounds in water by Purge & Trap or dynamic headspace

    Context & Challenges Volatile organic compounds (VOC) can be dissolved in water. Sometimes water is polluted and to study contamination of VOC in finished drinking water, VOC must be measured. Chromatotec® Solutions Chromatotec® has developed a specific system for the measurement of VOC in water: a Purge & Trap system, the airmoPURGE. The analyzer is coupled with a degasing system allowing the extraction of dissolved gases. The complete system is based on: - 502.2 method from US EPA – “Volatile organic compounds in water by purge and trap capillary column gas chromatography with photoionization and electrolytic conductivity detectors in series – Revision 2.1”. - 524.2 method from US EPA – “Measurement of purgeable organic compounds in water by capillary column gas chromatography/mass spectrometry – Revision 4.0”.

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    Measurement of ethylene oxide for monitoring workplace exposure limits

    The Series 8900 Ethylene Oxide Analyzer combines the selectivity of gas chromatography with the sensitivity of a Photoionization Detector (PID) providing interference free response to Ethylene Oxide (EtO) at levels below 0.05 ppm. This analytical method is referenced in OSHA`s `Occupational Exposure to Ethylene Oxide: Final Standard` 29 CFR Part 1910. The system documents exposure levels including: time-weighted averages (TWA), short-term exposure limits (STEL) and instantaneous alarms. Areas that are typically monitored include; EtO Sources - gas storage areas, sterilizer doors, aeration doors, and the General Work Area - decontamination, packaging and preparation and sterile product storage areas.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of methane, methanol and ethanol for the biomass monitoring for biofuels.

    The Series 8900 provides direct measurement of methane, methanol, and ethanol for the biofuel industry. The Series 8900 GC employs a flame ionization detector (FID). The methane, methanol, and ethanol in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and heavier gases. At sample injection, a fixed volume of sample is carried through the pre-cut column. The backflush is timed so that primarily the MME and other similar compounds continue on to the analytical column. Contaminants are then backflushed to vent. Methane, methanol, and ethanol are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Moisture Monitoring for Nuclear Reactors

    The Advanced Gas Cooled Reactor uses carbon dioxide gas to transfer heat from the nuclear fission core to the water boiler for steam generation. The moisture content needs to be monitored to avoid corrosion damage, and continuous moisture monitoring acts as a boiler leak detector or bulk moisture meter.

    By Moisture Control & Measurement Ltd based in Wetherby, UNITED KINGDOM.

  • Premium

    Aqua M300 Intelligent Geophone

    With the Aqua M300 leak detectors have a multifunctional tool to Pinpoint or Pre-locate leakages and to trace pipes in conjunction with a PWG. The biggest advantage compared to other related products are the 256 analogue and digital filters which enables the user to shut off disturbing noises very precisely. Also the extension for H2 tracer gas comes without competition and makes this device a essential tool for leak detectors.

    By F.A.S.T. GmbH based in Langenbrettach, GERMANY.

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to fixe or mobile ambient air quality monitoring laboratories. The VOC72M is fitted with a PID detector new generation, much more sensitive, more stable and whose lamp does not need to be cleaned; the analyzer integrates flow control fittings a 3 levels security system built on and uses only one gas (nitrogen). This robust and low maintenance instrument performs all the functions (sampling, analysis and data management) in a simple and completely autonomous mode. It is a particular

    By Environnement S.A based in Poissy, FRANCE.

  • End Point Detection

    Hiden Ion Milling Probe – End Point Detector The only dedicated end point determination tool for ion etch control and optimum process quality. End point Analysis. Target Impurity Determination. Quality Control / SPC. Residual Gas Analysis. Leak Detection The IMP is a differentially pumped, ruggedized secondary ion mass spectrometer for the analysis of secondary ions and neutrals from the ion mill process, featuring: High Sensitivity SIMS / MS with Pulse Ion Counting Detector. Triple filter Quadrupole, 300 amu mass range is standard. Differentially Pumped Manifold With Mounting Flange to Process Chamber. Ion Optics with Energy Analyser and integral ioniser. Penning Gauge and interlocks to provide over pressure protection. Data System with integration to the process tool. Stability (less than ±0.5% height variation over 24 h). MASsoft control via RS232, RS485 or Ethernet LAN. Programmable DDE, Parallel Digital I / O, RS232 Scripting Communication

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Saran Bag application

    Title : Preliminary Sampling Methodology and Analytical Procedures for Ambient Sulfur Hexafluoride, Corporate Author : ARMY MEDICAL ENVIRONMENTAL ENGINEERING RESEARCH UNIT EDGEWOOD ARSENAL MD Personal Author(s) : Luckan,Susan K. ; Cooper,William J. Report Date : JAN 1973 Pagination or Media Count : 23 Abstract : A preliminary evaluation of techniques of sampling and gas chromatographic analysis for low levels of sulfur hexafluoride was conducted to determine the most feasible method for available equipment. Using a Tracor MT-150 gas chromatograph equipped with Nickel 63 electron capture detector and polarized dc voltable, it was possible to detect sulfur hexafluoride at a concentration of 0.06 ppb with a 5A molecular sieve column and nitrogen carrier gas, without preconcentration of the sample. Also, a comparison of glass and Saran sampling materials proved that no detectable loss of the tracer gas resulted with the Saran bags (between 6 ppm and 0.06 ppb SF6

    By Analytical Specialties, Inc. based in Elburn, ILLINOIS (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you