Only show results in Texas? Ok

gas sampling Applications

  • Premium

    Premium gas generators and calibration solutions for sample evaporation sector

    Check our LNI Swissgas range of gas generators for Sample Evaporation applications.

    By LNI Swissgas based in Versoix, SWITZERLAND.

  • Premium

    Measuring aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    The Series 8900 BTEX Analyzer provides direct measurement of Benzene, Toluene, Ethylbenzene, and Xylenes in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites. The Series 8900 BTEX Analyzer employs a photoionization detector (PID) as the sensing element. This detector is specific to volatile organic compounds. The Benzene, Toluene, Ethylbenzene, and Xylene`s in the gas sample are physically separated using proprietary GC columns.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of methane, methanol and ethanol for the biomass monitoring for biofuels.

    The Series 8900 provides direct measurement of methane, methanol, and ethanol for the biofuel industry. The Series 8900 GC employs a flame ionization detector (FID). The methane, methanol, and ethanol in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and heavier gases. At sample injection, a fixed volume of sample is carried through the pre-cut column. The backflush is timed so that primarily the MME and...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Gas monitoring instruments and systems for engine emissions measurements

    The exhaust gas from combustion engines is a complex mixture of gases and particulate matter. The composition of the gas may change rapidly. Multicomponent analysis of exhaust gases can be performed with a Gasmet™ FTIR Gas Analyzer with a response time (T90) of one second. The winning combination is the result using of a small volume gas sample cell, a powerful sample pump and a fast detector with liquid nitrogen cooling. The analyzer, sampling system and computer can be assembled on a cart for use in a...

    By Gasmet Technologies Oy based in Vantaa, FINLAND.

  • Premium

    Measurement of acetaldehyde, methanol, & benzene in CO2 applications for gas manufacturers & food & beverage industry

    The BevAlert Model 8900 provides direct measurement of Acetaldehyde, Methanol, and Benzene (AMB) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace impurities in CO2 used in carbonated beverages. The BevAlert Model 8900 employs a photoionization detector (PID). The AMB in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Marine monitoring solutions for the SO2/CO2/NOx monitoring

    Process control of a SO2 scrubber on a ship is a challenge due to wet and corrosive gases. In such environment, extractive gas sampling systems require high levels of maintenance in order to operate correctly. OPSIS monitoring system solves this by using an optical, non-contact, cross-duct technique. A light beam is sent across the duct or stack to be measured, and the captured light is sent through an optical fibre cable to an analyser. The analyser measures SO2, CO2 and NOx concentrations using UV and IR...

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Chemiluminescense based analyzer for automotive applications

    Focuses on high NOx, NOx-related and multigas-concentrations up to 10’000 ppm. Parameters included are NO, NO2, NOx, NH3, NOx-amines, O2 and CO2. The applications are characterized by demanding sample gas conditions, such as in automotive, aviation, naval, or combustive engine emissions, as well as in catalyst production.

    By ECO PHYSICS AG based in Duernten, SWITZERLAND.

  • Premium

    Tunnel solutions for the extractive areas

    In some countries they do not allow tunnel atmosphere monitors to be mounted on the tunnel wall; also, where there is a single bore it is very difficult to gain access for maintenance purposes. The TunnelTech 400 series are extractive gaseous pollutant and visibility monitors and extract a gas and dust sample from the tunnel bore and carry to a remote analyser. This allows maintenance to take place without affecting tunnel traffic flow.

    By Codel International Ltd based in Bakewell, UNITED KINGDOM.

  • Continuous Emissions Monitoring

    Requirements for monitoring emissions to air are governed by EU/UK legislation and are implemented in the form of a permit by the Environment Agency or local authority. The Dr Foedisch muti-component gas analysers continuously extract a gas sample from the exhaust stream via a stack probe into the analyser cabinet. Both hot and cold gas systems are available, please contact us to discuss which system best suits your requirements.

    By CEM Solutions (UK) Ltd. based in Darley Dale, UNITED KINGDOM.

  • Premium

    Gas monitoring instruments and systems for process NOx measurement

    Nitric acid HNO3 is an important intermediate reagent for production of several important end products, such as fertilizers, explosives, dyestuffs/pigments, pesticides, pharmaceuticals, photographic materials, plastics, and synthetic fibers. At nitric acid manufacturing plants, the Gasmet™ FTIR Gas Analyzer can be used to measure several gaseous components from the process stream for purposes of process control. A single system can be used to measure the high levels of nitrogen monoxide NO and nitrogen...

    By Gasmet Technologies Oy based in Vantaa, FINLAND.

  • Premium

    Measurement of C1-C5 with carbon dioxide for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons and Carbon Dioxide required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Measurement solution for FTIR Vs. GC in gas analysis

    Comparison of TechnologiesA gas chromatograph (GC) has traditionally been the technology of choice for laboratory analysis of gas samples. GCs have been used for over 50 years in the qualification and quantification of complex mixtures of gases. The techniques and methodology required to run GCs are often a pre-requisite for any laboratory technician. Recent developments in Fourier Transform Infra-Red (FTIR) gas analysis has enabled this technology to start to replace GCs in the lab.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • NOx analyzers for automotive, aviation, marine, and combustive engines industry

    These applications are characterized by demanding sample gas conditions, such as in automotive, aviation, naval, or combustive engine emissions, as well as in catalyst production. Focuses on high NOx, NOx-related and multigas-concentrations up to 10’000 ppm. Parameters included are NO, NO2, NOx, NH3, NOx-amines, O2 and CO2. The applications are characterized by demanding sample gas conditions, such as in automotive, aviation, naval, or combustive engine emissions, as well as in catalyst production.

    By Eco Physics Inc. based in Ann Arbor, MICHIGAN (USA).

  • Premium

    Industrial monitoring solutions for the de-NOx plants areas

    In recent years the number of Selective Catalytic Reduction (SCR) and Selective Non-Catalytic Reduction (SNCR) plants for De-NOx have increased significantly. Continuous analysis of NOx prior to the de-NOx plant is often required to measure the concentration generated by the combustion process. This may be required to provide feed-forward to the Ammonia/Urea injection system and also to allow the effectiveness of the reduction process to be assessed. Continuous analysis of NOx post-reduction is required to allow...

    By Codel International Ltd based in Bakewell, UNITED KINGDOM.

  • Premium

    Measurement of acetaldehyde, benzene, toluene, ethylbenzene, & xylenes in CO2 applications for food & beverage industry

    The BevAlert Model 8900 provides direct measurement of Acetaldehyde, Benzene, Toluene, Ethylbenzene, and Xylenes (ABTEX) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace volatile organic compounds in CO2 used in carbonated beverages.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of C1-C5 hydrocarbons for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Filtration for Flue Gas Analysis and CEMS

    Three Steps of CEMS: 1st Step: Gas Sampling 2nd Step: Gas conditioning and treatment 3rd Step: Measurement/Calibration In first step, the function is to get sample gas and forward to 2nd step for treatment. During this step, it cannot block the probes and cannot result condensation of moisture. So a filter online back flushing should be equipped in this part. The filters to be used: 1, Filter is used to ensure the stability of system and reduce the maintenance 2, Filtration Grade: usually 2 or 3 micron 3,...

  • Premium

    Laboratory instruments solutions for environmental industry

    The environmental challenges require internationally accepted standards, in which limits and test methods are defined. Metrohm instruments and applications comply with a lot of international environmental standards. Substances introduced into the environment are distributed among the environmental compartments water, soil (sediment), and air, as well as among the organisms living in them (biosphere). Only if we know the type and quantity of these contaminants can we protect the environment and its inhabitants.

    By Metrohm AG based in Herisau, SWITZERLAND.

  • Premium

    Gas monitoring instruments and systems for fumigation

    Sea cargo containers and wooden packing materials are fumigated to control the spreading of pest animals and micro-organisms. Fumigant gases are toxic and measurements are carried out as a health and safety precaution. Measurements are required by e.g. customs inspectors prior to opening containers, making the shipping companies responsible for carrying out measurements. Products shipped in containers may release VOCs from e.g. solvents and glues used in manufacturing process. The concentrations of vapors may be...

    By Gasmet Technologies Oy based in Vantaa, FINLAND.

  • Premium

    Fire detection solutions for the power stations sector

    One of the main hazards in a power station is a fire in a coal rich environment; the latter can often become an explosion with consequential damage to human life and capital equipment.

    By Codel International Ltd based in Bakewell, UNITED KINGDOM.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you