Only show results available in Virginia? Ok

gas sampling equipment Applications

  • Premium

    Sampling and drilling equipments for the mining industry

    AMS, Inc. has been a leading provider of high quality sampling equipment since 1942. AMS sampling equipment is primarily used for environmental, geotechnical, and remediation uses as well as soil, soil gas, and groundwater monitoring. In addition, AMS makes PowerProbe direct push/hollowstem auger drill rigs for environmental and geotechnical drilling activities. AMS also manufactures and offers direct push tooling, drilling equipment, accessories, and expendables for soil sampling, groundwater sampling and monitoring well installations.

    By Art’s Manufacturing and Supply, Inc. (AMS Inc.) based in American Falls, IDAHO (USA).

  • Air Quality Monitoring Equipment for Sample Handling Industry

    Within the field of gas analysis much time is spent looking at the accuracy and uncertainty in the detection technique. However, without appropriate sample handling, what you are measuring could potentially bear little or no relation to your original sample.

    By Signal Group Ltd based in Camberley, UNITED KINGDOM.

  • Air and particule sampling for the oil and gas industries

    Ormantine offers a wide range of products and services to meet the array of different needs that arise in the oil and gas industries. Volatile Organic Compounds (VOCs), benzene, and other compounds are released during drilling, hydraulic fracturing (fracking) and other extraction procedures. Monitor NOx emissions from heavy duty equipment, particulate matter, and ground level ozone, the formation of which is contributed to by VOCs from processing, transportation, and storage of oil and gas.

    By Ormantine USA Ltd., Inc. based in Palm Bay, FLORIDA (USA).

  • Gas control equipment for Life Science

    QCAL introduces CO2Control for incubators and test chambers. These gas dosing units can be adapted to nearly every incubator or test chamber. The user can set a CO2 concentration up to 30% vol. CO2. The CO2Control measures the actual concentration and adds CO2 from a CO2 gas container. The NDIR CO2-sensor has an excellent long-term stability, which provides years of stable CO2 measurement. Also the other parts as the sample gas pump, valve and fittings are designed for maintenance-free use over years. Humidity effects are compensated upto 95% rh at 37°C, also temperature effects are automatically corrected upto 50°C. The other way to control gas atmospheres in any life science equipment is to use gas mixing units GMS_2CH ( 2 channels ) or GMS_3CH ( 3 channels ) for N2, O2 and CO2. They can match flowrates up to 80 liters per minute with a concentration range up to 100 Vol% O2 and/or CO2.

    By QCAL Messtechnik GmbH based in Oberostendorf, GERMANY.

  • Premium

    Measurement solution for multi-stream combustion research

    Protea supplied a complete turn-key measuring system for multi-point sampling in a University combustion research laboratory. Utilising the latest in FTIR spectroscopy, atmosFIR, a complete cabinet system was supplied containing: atmosFIR FTIR Gas analyser, Sampling System Control Module (SSCM), Heated Stream Selection Module (HSSM), Temperature Control Module (TCM), 4 heated sample lines, 4 heated sample probes, Embedded PC controller.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Filtration for Flue Gas Analysis and CEMS

    Three Steps of CEMS: 1st Step: Gas Sampling 2nd Step: Gas conditioning and treatment 3rd Step: Measurement/Calibration In first step, the function is to get sample gas and forward to 2nd step for treatment. During this step, it cannot block the probes and cannot result condensation of moisture. So a filter online back flushing should be equipped in this part. The filters to be used: 1, Filter is used to ensure the stability of system and reduce the maintenance 2, Filtration Grade: usually 2 or 3 micron 3, Temp. is around 0-180 deg C 4, Back flushing gas is heated, impulse flushing 5, Filter Material: Titanium Sintered, SS316L Sintered, PTFE sintered, Ceramic Membrane and so on 2nd Step Gas Treatment: #11;The coarse filters and the liquid particle filters The coarse and fine cartridge can filter the small particles in the gas and acid aerosol things to better protect the instruments. The micron can be 0.1micron, filtration rate can be up to 99.99%, two layers can be 99.9999%

    By Shanghai CMI Environmental Technology Co.,Ltd. based in Shanghai , CHINA.

  • Saran Bag application

    Title : Preliminary Sampling Methodology and Analytical Procedures for Ambient Sulfur Hexafluoride, Corporate Author : ARMY MEDICAL ENVIRONMENTAL ENGINEERING RESEARCH UNIT EDGEWOOD ARSENAL MD Personal Author(s) : Luckan,Susan K. ; Cooper,William J. Report Date : JAN 1973 Pagination or Media Count : 23 Abstract : A preliminary evaluation of techniques of sampling and gas chromatographic analysis for low levels of sulfur hexafluoride was conducted to determine the most feasible method for available equipment. Using a Tracor MT-150 gas chromatograph equipped with Nickel 63 electron capture detector and polarized dc voltable, it was possible to detect sulfur hexafluoride at a concentration of 0.06 ppb with a 5A molecular sieve column and nitrogen carrier gas, without preconcentration of the sample. Also, a comparison of glass and Saran sampling materials proved that no detectable loss of the tracer gas resulted with the Saran bags (between 6 ppm and 0.06 ppb SF6

    By Analytical Specialties, Inc. based in Elburn, ILLINOIS (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you