Only show results available in Virginia? Ok

gas sampling system Applications

  • Premium

    Gas monitoring instruments and systems for engine emissions measurements

    The exhaust gas from combustion engines is a complex mixture of gases and particulate matter. The composition of the gas may change rapidly. Multicomponent analysis of exhaust gases can be performed with a Gasmet™ FTIR Gas Analyzer with a response time (T90) of one second. The winning combination is the result using of a small volume gas sample cell, a powerful sample pump and a fast detector with liquid nitrogen cooling. The analyzer, sampling system and computer can be assembled on a cart for use in a dynamometer laboratory, or the portable version can be used for roadside tests.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Gas monitoring instruments and systems for process NOx measurement

    Nitric acid HNO3 is an important intermediate reagent for production of several important end products, such as fertilizers, explosives, dyestuffs/pigments, pesticides, pharmaceuticals, photographic materials, plastics, and synthetic fibers. At nitric acid manufacturing plants, the Gasmet™ FTIR Gas Analyzer can be used to measure several gaseous components from the process stream for purposes of process control. A single system can be used to measure the high levels of nitrogen monoxide NO and nitrogen dioxide NO2, as well as water vapor H2O, nitrous oxide N2O, carbon monoxide CO, carbon dioxide CO2 and ammonia NH3. The fixed installation products for these purposes are the Gasmet™ CEM II measurement system, and the Gasmet™ FCX Gas Analyzers, both of which utilize the FTIR measurement technique for simultaneous multicomponent analysis of the sample gas.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Gas analysis & monitoring system for medical gases monitoring

    The measurement of occupational exposure to pollutants in the operating room is an essential tool for the detection of chemical, linked not only to the occurrence of infections and various diseases, but also to reduced alertness and performance of staff. To meet the above requirements, ETG proposes the use of ‘INFRARUN, thanks to the high sensitivity and stability and the very wide dynamic range, INFRARUN is the ideal tool to make a continuous sampling in the short and long-term gaseous contaminants in the field hospital, such as volatile anesthetics, aldehydes, fluorani, isofluorani,, VOC’s, etc.

    By ETG Risorse e Tecnologia based in Montiglio, ITALY.

  • Exhaust Gas Emissions

    Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas/vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, & include a range of special sampling, vacuum pumping & vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, & thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR studies, Hiden gas analysis systems include enhanced pumping for hydrogen and special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour & CH4 in the PPM to 100% concentration range provides vital ininformation for process development and process monitoring...

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Gas Analysis Systems for Catalysis, Thermal Analysis, Fermentation and Bio Fuels

    Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas and vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, and include a range of special sampling, vacuum pumping and vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, and thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR, studies, Hiden gas analysis systems include enhanced pumping for hydrogen and special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour and CH4 in the PPM to 100% concentration range provides vital information for process development and process monitoring.

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Fermentation Off-Gas Analysis

    In pilot plant and production scale fermentors, information relating to yield of product is of high importance. Hiden's gas analysers are configured with a multiport Off-Gas analysis manifold enabling simultaneous sampling from multiple fermentors. Data is used for the calculation of the respiratory quotient, carbon production rate and oxygen uptake rate. The Off-Gas measurement provides the respiratory quotient in a time and space averaged form and with good response time. By comparison data from multiple dissolved species probes are more specific and can provide information about stirring efficiency, aeration and feed distribution within the fermentor. Dissolved gas measurements have the advantage of giving direct information on gas uptake and for dissolved output rates. Hiden Analyticaloffers systems with either Off-Gas or dissolved species inlets or both.

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Fermentation Off-Gas Analysis

    In pilot plant and production scale fermentors, information relating to yield of product is of high importance. Hiden's gas analysers are configured with a multiport Off-Gas analysis manifold enabling simultaneous sampling from multiple fermentors. Data is used for the calculation of the respiratory quotient, carbon production rate and oxygen uptake rate. The Off-Gas measurement provides the respiratory quotient in a time and space averaged form and with good response time. By comparison data from multiple dissolved species probes are more specific and can provide information about stirring efficiency, aeration and feed distribution within the fermentor. Dissolved gas measurements have the advantage of giving direct information on gas uptake and for dissolved output rates. Hiden Analyticaloffers systems with either Off-Gas or dissolved species inlets or both.

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Real Time Gas Analysis - Calorimetry Reaction

    Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas and vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, and include a range of special sampling, vacuum pumping and vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, and thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including temperature programmed desorption TPD , temperature programmed oxidation TPO, and temperature programmed reduction TPR, studies, Hiden gas analysis systems include enhanced pumping for hydrogen and special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response...

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Filtration for Flue Gas Analysis and CEMS

    Three Steps of CEMS: 1st Step: Gas Sampling 2nd Step: Gas conditioning and treatment 3rd Step: Measurement/Calibration In first step, the function is to get sample gas and forward to 2nd step for treatment. During this step, it cannot block the probes and cannot result condensation of moisture. So a filter online back flushing should be equipped in this part. The filters to be used: 1, Filter is used to ensure the stability of system and reduce the maintenance 2, Filtration Grade: usually 2 or 3 micron 3, Temp. is around 0-180 deg C 4, Back flushing gas is heated, impulse flushing 5, Filter Material: Titanium Sintered, SS316L Sintered, PTFE sintered, Ceramic Membrane and so on 2nd Step Gas Treatment: #11;The coarse filters and the liquid particle filters The coarse and fine cartridge can filter the small particles in the gas and acid aerosol things to better protect the instruments. The micron can be 0.1micron, filtration rate can be up to 99.99%, two layers can be 99.9999%

    By Shanghai CMI Environmental Technology Co.,Ltd. based in Shanghai , CHINA.

  • Premium

    Capabilities of the Adsorbent Tube Injector System (ATIS™)

    The Adsorbent Tube Injector System (ATIS) was developed at Supelco® by R&D Scientists, as a tool to assist in our comprehensive adsorbent research for thermal desorption tubes. The ATIS provides an efficient means of transferring calibration standards in either the gas or liquid phase onto the adsorbent packed tubes. The ATIS employs the technique of flash vaporization to vaporize the sample in a continuous flow of inert gas; the inert gas carries the sample to the tube. The sample pathway of the ATIS is constructed of glass and stainless steel. The calibration standard is injected by a syringe through a replaceable septum in the center of the injection glassware, which is heated. After enough time has elapsed, typically less than five minutes, the tube is removed from the ATIS and analyzed using the appropriate analytical technique for that adsorbent tube.

    By Sigma-Aldrich Co., LLC based in Bellefonte, PENNSYLVANIA (USA).

  • Premium

    Measurement solution for multi-stream combustion research

    Protea supplied a complete turn-key measuring system for multi-point sampling in a University combustion research laboratory. Utilising the latest in FTIR spectroscopy, atmosFIR, a complete cabinet system was supplied containing: atmosFIR FTIR Gas analyser, Sampling System Control Module (SSCM), Heated Stream Selection Module (HSSM), Temperature Control Module (TCM), 4 heated sample lines, 4 heated sample probes, Embedded PC controller.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to fixe or mobile ambient air quality monitoring laboratories. The VOC72M is fitted with a PID detector new generation, much more sensitive, more stable and whose lamp does not need to be cleaned; the analyzer integrates flow control fittings a 3 levels security system built on and uses only one gas (nitrogen). This robust and low maintenance instrument performs all the functions (sampling, analysis and data management) in a simple and completely autonomous mode. It is a particular

    By Environnement S.A based in Poissy, FRANCE.

  • Microbial Studies

    Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas/vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, & include a range of special sampling, vacuum pumping & vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, & thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR studies, Hiden gas analysis systems include enhanced pumping for hydrogen & special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour & CH4 in the PPM to 100% concentration range provides vital information for process development and process monitoring.

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Beverage Analysis

    Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas/vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, & include a range of special sampling, vacuum pumping and vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, & thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR studies, Hiden gas analysis systems include enhanced pumping for hydrogen and special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour & CH4 in the PPM to 100% concentration range provides vital information for process development and process monitoring

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Fragrance Fingerprinting

    Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas & vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, & include a range of special sampling, vacuum pumping & vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, and thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR, studies, Hiden gas analysis systems include enhanced pumping for hydrogen and special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour and CH4 in the PPM to 100% concentration range provides vital information for process development and process monitoring.

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you