Only show results available in Virginia? Ok

groundwater sample Applications

  • Premium

    Continuous sampling of groundwater wells

    By Argus-Hazco based in Chesterfield, MICHIGAN (USA).

  • Premium

    Lipophilic sampling for groundwater testing

    By Exposmeter AB based in Tavelsjö, SWEDEN.

  • Premium

    Environmental sampling for soil researching

    By Argus-Hazco based in Chesterfield, MICHIGAN (USA).

  • Premium

    Sampling and drilling equipments for the mining industry

    AMS, Inc. has been a leading provider of high quality sampling equipment since 1942. AMS sampling equipment is primarily used for environmental, geotechnical, and remediation uses as well as soil, soil gas, and groundwater monitoring. In addition, AMS makes PowerProbe direct push/hollowstem auger drill rigs for environmental and geotechnical drilling activities. AMS also manufactures and offers direct push tooling, drilling equipment, accessories, and expendables for soil sampling, groundwater sampling and monitoring well installations.

    By Art’s Manufacturing and Supply, Inc. (AMS Inc.) based in American Falls, IDAHO (USA).

  • Monitoring of VOCs in Porewater

    Monitoring VOCs in porewater in the unsaturated zone is now possible.

    Sorbisense regularly offers new options for using the patented Sorbicell, which is used to monitor surface water, wastewater and groundwater.

    The latest is almost as “ground-breaking” as the SorbiCell itself. Until now it has been difficult, if not impossible, to directly monitor for volatile substances in pore water in the unsaturated zone. But the environmental consultancy firm Ejlskov A/S in Aarhus combined the use of Sorbisense sampling equipment with the proven technology of soil water samplers. With this combination, a practical new method is made available, which allows for monitoring the presence of porewater-dissolved VOCs above the groundwater table. This provides a significantly improved basis to define and determine the leaching risk to the groundwater, and thus allows for better and more cost-efficient decisions to prevent the pollution in reaching the groundwater.

    A simple construction with multiple options

    The application uses SorbiCell VOC combined with suction cells, soil water samplers. When installed correctly, and applied with the correct procedures, the suctions cells extract capillary bound water from the soil matrix. The system demands no other resource than a container that is put under vacuum. The vacuum in the container then ensures a flow through of the Sorbicell over a period of time, fx. 2-3 weeks. The method is highly suitable for monitoring a site over longer periods of time.

    By SORBISENSE based in Tjele, DENMARK.

  • Premium

    Oil in Water Analysis for Flowback or Produced Water

    The amount of water used in and produced by hydraulic fracturing of shale gas wells is in the millions of gallons per well. Whether the water is going to be taken off site for disposal or reused for re-injection, the flowback or produced water needs pretreatment to remove any residual oil from the water. Waiting for remote lab results can take several days to a week. InfraCal TOG/TPH Analyzers allow for oil in water testing at the well site in less than 10 minutes. The sampling requires a few simple steps that can be performed by non-technical personnel. The water is mixed with the extraction solvent, shaken, and then presented to the analyze for measurement. The same InfraCal TOG/TPH Analyzer can be used for TPH in soil if a spill or pond leak occurs to determine the contaminated area. The analyzer features: -Results in under 15 minutes -Detect levels as low as 10 ppm -Portable, rugged, lightweight, easy-to-use -Battery operable -Ideal for field or lab use

    By Spectro Scientific based in Chelmsford, MASSACHUSETTS (USA).

  • Data analysis and visualization tools for monitoring well decommissioning

    Contaminated groundwater sites worldwide are engaged in regular sampling of monitoring wells at a typical cost of $1,500 per well-sampling event. On most sites, many wells are redundant or geostatistically insignificant and can be decommissioned.
    EVS-PRO and MVS`s Well Decommission module analyses all available data and quantifies the impact on site assessment quality associated with removing each well. The impact of removing a well is quantified in terms of its impact on the geostatistical plume extent.
    During remediation plumes are shrinking and may drift. This can necessitate decommissioning of some wells and adding new wells. C Tech`s well decommissioning and DrillGuide© technology provide the tools to properly monitor and guide the remediation efforts at the lowest possible cost.

    By C Tech Development Corporation based in Henderson, NEVADA (USA).

  • Rapid Site Cleanup, Closure & Resale

    We can help you achieve site closure and enable the sale or redevelopment of your site in a predictable timeframe with highly reliable results. This is made possible by: Our broad array of thermal remediation technologies, each tailored to the site-specific conditions and contaminants; Tested and proven field operations, processes, and teams; Expertise in designing projects to ensure outcomes without the need for further remediation; and, Our ability to assure a shorter project cycle and verification that goals are achieved by sampling before we shut down or demobilize.

    By TerraTherm, Inc. based in Gardner, MASSACHUSETTS (USA).

  • Premium

    Measurement of naphthalene in ambient air to monitor workplace exposure limits & at remediation & Superfund sites

    The Series 8900 Naphthalene Analyzer provides direct measurement of Naphthalene in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits and at remediation and Superfund sites. The Series 8900 Naphthalene Analyzer employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Naphthalene and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Naphthalene is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON - Baseline based in Lyons, COLORADO (USA).

  • Water Data Management Solution for Urban Hydrology

    Use KISTERS solutions to manage all of the various data from your Urban Water Management programs. From water distribution to water treatment, infiltration and inflow studies, groundwater, as well as long term precipitation monitoring and real time control systems. An optional water quality module is also available to manage your discrete sample data.

    By KISTERS group based in Aachen, GERMANY.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you