Only show results available in Virginia? Ok

h2s control plant Applications

  • Premium

    Waste water treatment plants Personnel Safety & H2S filter management

    Context & Challenges Globally, the wastewater treatment is the first public health issue. Urban development leads to urbanization near waste water treatment plant and extension of sewerage network. These aspects induce to an augmentation of sulfur compounds (H2S, mercaptans and sulfides) which are very corrosive, odorant and toxic. To monitor this compounds online CHROMATOTEC® offers high meteorological solutions. As a result of the confinement of the waste water stations, toxic components such as H2S and Methylmercaptan increased. Safety of employees on such working sites has therefore become of major problem. To fight this hazardous pollution, air filtering systems have been installed. For the station managers, personal safety coupled with the need for constant air quality control and filter change has been a heavy task.

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    Waste water treatment plants Air quality control by TRS MEDOR

    Context & Challenges Globally, the wastewater treatment is the first public health issue. Urban development leads to urbanization near waste water treatment plant and extension of sewerage network. These aspects induce to an augmentation of sulfur compounds (H2S, mercaptans and sulfides) which are very corrosive, odorant and toxic. To monitor this compounds online CHROMATOTEC® offers high meteorological solutions. At the entrance of the waste water plants, where the waste water arrives, strongly smelling and polluted air is captured and neutralised by a chemical cleaning process called ‘’Stripping’’. The correct amount of chemical products needed to neutralise the polluted air has to be calculated.

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    Waste water treatment plants Air quality control by TRS MEDOR Online Odor Monitoring

    ontext & Challenges Globally, the wastewater treatment is the first public health issue. Urban development leads to urbanization near waste water treatment plant and extension of sewerage network. These aspects induce to an augmentation of sulfur compounds (H2S, mercaptans and sulfides) which are very corrosive, odorant and toxic. To monitor this compounds online CHROMATOTEC® offers high meteorological solutions. Odors are very distinct air contaminants as they generate nuisances. The factors playing a role in the determination of odor annoyance are: odor concentration and intensity, frequency, appreciation, duration, synergy and location. CHROMATOTEC® proposes an automatic solution to well identify the origin and the level of odors.

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Dust collection and odor control in waste management sites

    Th turn key plant is composed by three different wet stages. The first stage is a venturi jet scrubber to collect dust and particles, then the second and third stages are deputed to absorb bad smells, such as H2S, Ammonia and Ammines. The absorption takes place thanks to the injection of chemicals (such as Sulphuric Acid, Sodium Hypochlorite and Sodium hydroxide.

    By F.G.M. engineering srl based in S.Croce S/Arno (PI), ITALY.

  • Gravity Main Sulfide Odor Control with Hydrogen Peroxide

    Gravity main sewer systems include major trunk lines and the tributaries that feed them. Hydrogen sulfide (H2S) odor builds up in the collections system as the flows collect from upstream reaches and become larger, deeper and more septic (oxygen depleted) in the downstream reaches more near to the wastewater treatment plant. In general, most of the more significant hydrogen sulfide odor and corrosion control problems occur in the major trunk systems segments conveying flow to the plant. Therefore, selection of sulfide treatment for gravity systems has several options depending mainly on: Duration of control required Degree of septicity (oxygen depletion) Location of target control points or "hot spots" Location of available dosing points upstream of "hot spots" Availability of civil infrastructure and utilities Sensitivity to hazardous chemicals

    By USP Technologies based in Atlanta, GEORGIA (US) (USA).

  • Headworks Odor and Corrosion Control Using Hydrogen Peroxide

    Hydrogen Peroxide typically controls odors and corrosion at treatment plant headworks by direct oxidation of hydrogen sulfide (H2S) within the wastewater. In the direct oxidation mode, H2O2 is applied to the wastewater 5-30 minutes prior to the point where the odors are being released, generally as the wastewater line enters the plant boundary. The efficiency of hydrogen peroxide treatment depends upon the available reaction time, the level of iron in the wastewater (reaction catalyst), wastewater pH and temperature, and the initial and target levels of H2S odor. Under optimal conditions, effective dose ratios are 1.2 - 1.5 parts H2O2 per part dissolved sulfide, and can be reliably estimated through beaker tests. H2O2 + H2S → S0 + 2H2O Frequently, control of odors through the primary clarifiers is wanted. In such case, the mechanism of control is both direct oxidation of H2S (as it rises from the solids blanket), and prevention of odor generation (by supplying dissolved oxygen). Control is typically achieved with a booster dose of 1-2 mg/L H2O2 added to the clarifier influent. Higher doses or alternate modes of addition may be required in cases where: 1) hydraulic retention times are > 2-3 hours; 2) solids blanket depths are > 1-2 feet; 3) soluble BOD levels are > 200-300 mg/L; or 4) waste activated sludge is co-settled with the primary solids. 2H2O2 → O2 + 2H2O

    By USP Technologies based in Atlanta, GEORGIA (US) (USA).

  • Sulfide Oxidation with Hydrogen Peroxide (H2O2)

    Sulfide Odor Control Sulfide is found throughout the environment as a result of both natural and industrial processes. Most sulfide found in nature was produced biologically (under anaerobic conditions) and occurs as free hydrogen sulfide (H2S) - characterized by its rotten egg odor. We are most likely to encounter biogenic H2S in sour groundwaters, swamps and marshes, natural gas deposits, and sewage collection/treatment systems. Manmade sources of H2S typically occur as a result of natural materials containing sulfur (e.g., coal, gas and oil) being refined into industrial products. For a variety of reasons - aesthetics (odor control), health (toxicity), ecological (oxygen depletion in receiving waters), and economic (corrosion of equipment and infrastructure) - sulfide laden wastewaters must be handled carefully and remediated before they can be released to the environment. Typical discharge limits for sulfide are < 1 mg/L. Sulfide Treatment Alternatives There are dozens of alternatives for treating sulfide laden waters, ranging from simple air stripping (for the low levels present in groundwaters) to elaborate sulfur recovery plants (used to treat several tons per day at refineries and coal burning power plants). There are processes based on biology (using compost filters, scrubbing media, or inhibition/disinfection), chemistry (oxidation, precipitation, absorption, and combination), and physics (adsorption, volatilization, and incineration). Each process occupies a niche which is often defined by the scale and continuity of treatment, whether the sulfide is in solution or is a gas, the concentration of sulfide involved, and the disposition of the sulfide containing medium. However, for reasons relating to convenience and flexibility, chemical oxidation (using hydrogen peroxide) continues to grow in its scope of application. Treatment with Hydrogen Peroxide While other peroxygens such as permonosulfuric (Caro’s) acid, peracetic acid, and persulfates will oxidize sulfide, their use for this application is overkill. Hydrogen peroxide (H2O2) is considerably simpler and more cost-effective. H2O2 may control sulfides in two ways, depending on the application: Prevention - by providing dissolved oxygen which inhibits the septic conditions which lead to biological sulfide formation; and Destruction - by oxidizing sulfide to elemental sulfur or sulfate ion.

    By USP Technologies based in Atlanta, GEORGIA (US) (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you