Only show results available in Virginia? Ok

h2s gas Applications

  • Hydrogen Sulfide (H2S) monitoring

    Hydrogen sulfide is the chemical compound with the formula H2S. H2S is colorless, toxic and flammable and is responsible for the foul odour of rotten eggs and flatulence. Hydrogen sulfide often results from sulfur reducing bacteria in nonorganic matter (in the absence of oxygen), such as in swamps and sewers (anaerobic digestion). H2S also occurs in volcanic gases, natural gas and some well waters.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Premium

    Analysis of H2S, Mercaptans and/or THT in natural gas with energyMEDOR

    Context & Challenges How to analyze H2S, mercaptans and/or THT for detecting the odor of the gas with the ability to have total organic sulfur calculation in a metering station?

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Gas Detection Solutions for Sour Gas

    The sour (H2S) content of hydrocarbon fields worldwide is increasing, and many natural gas fields have very high H2S – sometimes in excess of 50%. H2S is extremely dangerous because, although people can smell it at low levels (about 5 ppb) it does not smell much worse at the exposure limit value of 10 ppm or at potentially fatal levels in excess of 100 ppm. Therefore smell is an unreliable means of determining dangerous levels. Existing H2S point sensors are maintenance intensive, slow to respond and provide limited coverage. Most H2S sensors do not work reliably in hot or cold weather, or in humid marine environments.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Industrial Solution for gasification & synthetic gas

    Gasification and synthetic gas production from various waste products are becoming increasingly important energy recovery technologies. Often, the synthetic gas contains various hazardous contaminants including H2S, HCl and other acids, heavy metals, and tars. The gas requires cleaning before it is introduced in the engine or boiler. Most of these processes generate significant concentration of tars. The tars can vary from very low molecular weight to large and complex chains.

    By Macrotek Inc. based in Markham, ONTARIO (CANADA).

  • Hydrogen sulfide removal treatment for oil and gas industry

    The chemicals used for treating for H2S in the oil and gas industry can sometimes be just as hazardous as the H2S itself. MIOX wants to eliminate these hazardous chemicals and let oil & gas companies create their own safe chemistry on-demand as they need it. Whether it is high volume treatment, or low volume treatments in the middle of nowhere with no resources, we have a solution for your need.

    By MIOX Corporation - Johnson Matthey`s Water Technologies based in Albuquerque, NEW MEXICO (USA).

  • Exhaust Gas Emissions

    Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas/vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, & include a range of special sampling, vacuum pumping & vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, & thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR studies, Hiden gas analysis systems include enhanced pumping for hydrogen and special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour & CH4 in the PPM to 100% concentration range provides vital ininformation for process development and process monitoring...

    By Hiden Analytical Ltd. based in Warrington, UNITED KINGDOM.

  • Disposal wells treatment for oil and gas industry

    Treating the water being injected for disposal is not always considered by operators. This is likely costing you money in the long run. Removing iron, heavy metals, and treating out ammonia is a benefit to treating with MIOX’s mixed oxidant solution. While these are benefits of the technology, the most important is the elimination of bacteria which can cause Hydrogen Sulfide (H2S), corrosion pitting, poor injectivity and other problems, resulting in great well workover frequency. Treating injection wells does not need to be expensive, and can be treated as you inject.

    By MIOX Corporation - Johnson Matthey`s Water Technologies based in Albuquerque, NEW MEXICO (USA).

  • Activated carbons for air and gas industries

    Carbon Activated Corporation supplies a complete line of high-capacity activated carbon for vapor phase and air applications such as odor control in municipal waste-water facilities, landfills and refineries, SVE (soil vapor extraction) projects and many other vapor related applications. We manufacture specialized carbon both impregnated and non-impregnated for applications such as H2S removal and the removal of any time of noxious gases.

    By Carbon Activated Corporation based in Compton, CALIFORNIA (USA).

  • Premium

    Gas analysis & monitoring system for biogas analysis

    “Biogas” means a mixture of various types of gas (mostly methane) produced by bacterial fermentation in anaerobic conditions(absence of oxygen) of organic residues from waste, decaying plant, carcasses in putrescence. The analyzers of biogas by Infrared cells carry out the continuous analysis of CH4, O2, CO2, H2S and NH3. The whole process sees the decomposition of organic material by some types of bacteria, producing carbon dioxide, molecular hydrogen and methane(methane conversion of organic compounds).

    By ETG Risorse e Tecnologia S.r.l. based in Montiglio, ITALY.

  • Integrated real-time gas analysis solution for combustion efficiency sector

    CIC Photonics has made its mark with several R&D institutes where research is underway to determine the optimum thermodynamic performance of new turbine engine designs combined with new diesel fuel formulations. This sophisticated IRGAS technology has included not only a basic FTIR gas analyzer but also analyzers for H2, O2, THC, and a powder meter all integrated into a comprehensive IRGAS Solution.

    By CIC Photonics, Inc. based in Albuquerque, NEW MEXICO (USA).

  • Integrated real-time gas analysis solution for emissions industry

    Pollutant emissions from industrial smoke stacks are a major national concern due to both health concerns and climate change. As a consequence, there are at least tens of gas analyzer manufacturers in the U.S. alone that compete in that market and have done so for years. What CIC Photonics brings to that competitive field is its expertise derived from its Combustion Efficiency Solution and its high performance IRGAS Systems. The IRGAS-CEM provides real-time and simultaneous measurements of the multitude of toxic combustion products, including CO, CO2, NOx, SOx, CH4, CxHy, H2S, etc. The EP-IRGAS-SPA is also applicable for fast time responses.

    By CIC Photonics, Inc. based in Albuquerque, NEW MEXICO (USA).

  • Gas Analysis Systems for Catalysis, Thermal Analysis, Fermentation and Bio Fuels

    Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas and vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, and include a range of special sampling, vacuum pumping and vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, and thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR, studies, Hiden gas analysis systems include enhanced pumping for hydrogen and special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour and CH4 in the PPM to 100% concentration range provides vital information for process development and process monitoring.

    By Hiden Analytical Ltd. based in Warrington, UNITED KINGDOM.

  • Premium

    Aqua M300 Intelligent Geophone

    With the Aqua M300 leak detectors have a multifunctional tool to Pinpoint or Pre-locate leakages and to trace pipes in conjunction with a PWG. The biggest advantage compared to other related products are the 256 analogue and digital filters which enables the user to shut off disturbing noises very precisely. Also the extension for H2 tracer gas comes without competition and makes this device a essential tool for leak detectors.

    By F.A.S.T. GmbH based in Langenbrettach, GERMANY.

  • Premium

    Ultraviolet disinfection systems for the well injection water & SRB reduction

    Microorganism and bacteria control is increasingly an important topic of discussion in the oil and gas industry.  Inadequate disinfection and treatment of well injection water and stimulation fluids, used in the recovery of oil and gas has been proven to lead to a host of negative consequences, including: - Souring the well with hydrogen sulphide gas H2S, Microbiological induced corrosion, Loss of fluid stability during injection., Plugging of the well, Damage of equipment and components (e.g. RO membranes, filters)

    By atg UV Technology based in Wigan, UNITED KINGDOM.

  • Premium

    Ultraviolet disinfection systems for the produced water treatment

    With environmental regulations becoming more stringent, and the link between re-injected water quality and operational costs becoming clear to operators, investing early in advanced water treatment solutions for produced water for both reinjection applications and environmental discharges is now a top priority for operators worldwide.  atg UV Technology have provided a number of specialist UV packages for the disinfection of Produced Water in order to reduce microorganisms such as SRB’s (Sulphate Reducing Bacteria), Acid Producing Bacteria and Slime Forming Bacteria, that if left untreated, pose a range of negative consequences including: - Souring the well with hydrogen sulphide gas H2S, Microbiological induced corrosion, Loss of fluid stability during injection, Plugging of the well, Damage of equipment and components (e.g. RO membranes, filters).

    By atg UV Technology based in Wigan, UNITED KINGDOM.

  • Biogas for Cooking

    This solution comprises a Biogas Digester of desired capacity working with specific substrate as input. It may or may not have H2S scrubbing system, depending on the quantity of H2S in the biogas and the requirement by the customer for cleaning it. As the heating value of biogas is almost half that of cooking LPG, specially designed biogas burners are provided to improve cooking speed. Depending on the demand by the customer, a blower to increase gas pressure may be employed.

    By Kirloskar Integrated Technologies Limited based in Kothrud, INDIA.

  • Total Reduced Sulfur (S) monitoring

    Total reduced sulfur(s), which include hydrogen sulfide (H2S), methyl mercaptan (methanethiol, CH3SH), dimethyl sulfide (CH3SCH3), and dimethyl disulfide (CH3S2CH3), occur naturally in the environment and can also be present in numerous industrial gaseous streams – petroleum refining, natural gas extraction, and chemical operations like the pulp/paper industry. Hydrogen sulfide is the most prevalent of the total reduced sulfurs, and is commonly found in volcanic gases, marshes and swamps, wetlands and mud flats, sulfur springs and decaying organic matter. Additionally, hydrogen sulfide is produced by living organisms, including human beings, through the digestion and metabolization of sulfur-containing materials. It must be noted that sulfur dioxide (SO2), sulfur trioxide (SO3) and sulfuric acid mist are not included in the determination of TRS, as these are oxidized sulfur compounds and are permitted and monitored separately from TRS.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Biogas to Elecricity

    The range of supply of biogas to electricity solutions is from 10 kW to 1 MW. All the components of the solution are provided with matching capacities. It comprises the biogas digester system of the desired capacity, gas storage, biogas cleaning system to get rid of H2S from the gas, and the biogas genset. In the digester system, one may have a pre-digester or a feed mixing chamber or both. On the post-digester side, liquid from the slurry is separated and is recycled for feed preparation. It reduces the overall fresh water demand of the scheme. The digester itself may be temperature controlled and the input for the same could be given from heat recovery of the genset or from a solar heating system or from any other heat source as the case may be.

    By Kirloskar Integrated Technologies Limited based in Kothrud, INDIA.

  • Microbial Studies

    Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas/vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, & include a range of special sampling, vacuum pumping & vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, & thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR studies, Hiden gas analysis systems include enhanced pumping for hydrogen & special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour & CH4 in the PPM to 100% concentration range provides vital information for process development and process monitoring.

    By Hiden Analytical Ltd. based in Warrington, UNITED KINGDOM.

  • Measurement solution for hydrogen fuel cell testing

    As the alternatives to fossil fuels for power generation and automotive power become more widespread and preferred, so has increased the research and testing of hydrogen gas in fuel cells. The hydrogen (H2) gas used in fuel cell has to be free of impurities in order to make the fuel cell as efficient as possible and so quality thresholds have been set in legislation. Such legislation as SAE J2719 provides hydrogen fuel quality standards for proton exchange membrane (PEM) fuel cell vehicles. If impurities above these thresholds are present in the H2 fuel then there is a risk of not only making the cell inefficient, but also unrecoverable back to its peak operating voltage as the fuel cell electrode becomes poisoned.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you