Only show results available in Virginia? Ok

hydrocarbon pollution Applications

  • Premium

    Low level measurement of aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring.

    The Series 8900 BTEX Analyzer with a high-sensitivity PID provides direct low level measurement of Benzene, Toluene, Ethylbenzene, and Xylene`s in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites.

    By MOCON, Inc. - Baseline - AMETEK based in Lyons, COLORADO (USA).

  • Premium

    Measuring aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    The Series 8900 BTEX Analyzer provides direct measurement of Benzene, Toluene, Ethylbenzene, and Xylenes in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites. The Series 8900 BTEX Analyzer employs a photoionization detector (PID) as the sensing element. This detector is specific to volatile organic compounds. The Benzene, Toluene, Ethylbenzene, and Xylene`s in the gas sample are physically separated using proprietary GC columns.

    By MOCON, Inc. - Baseline - AMETEK based in Lyons, COLORADO (USA).

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to fixe or mobile ambient air quality monitoring laboratories. The VOC72M is fitted with a PID detector new generation, much more sensitive, more stable and whose lamp does not need to be cleaned; the analyzer integrates flow control fittings a 3 levels security system built on and uses only one gas (nitrogen). This robust and low maintenance instrument performs all the functions (sampling, analysis and data management) in a simple and completely autonomous mode. It is a particular

    By Environnement S.A based in Poissy, FRANCE.

  • Premium

    Measurement of methane and non-methane hydrocarbons for environmental air quality.

    The Model 8900 Methane/Non-Methane Analyzer provides direct measurement of Methane and Non-Methane Hydrocarbons. This instrument is utilized in ambient air monitoring networks around metropolitan areas, fence-line monitoring at industrial plants and hazardous waste sites, and in the production of high purity industrial gases. Methane is a naturally occurring gas generated from the decomposition of biological materials and industrial activity. Since Methane is not considered a pollutant it is the Non-Methane hydrocarbons that are of primary concern.

    By MOCON, Inc. - Baseline - AMETEK based in Lyons, COLORADO (USA).

  • Premium

    Petrochemical

    Durable regenerative thermal oxidizer (RTO) technology is at the core of our systems. MEGTEC designs and engineers system solutions to meet your special requirements, ranging from energy-efficient treatment of dilute volatile organic compound (VOC) flows, such as tank ventilation, to demanding applications utilizing VOC energy for secondary heat recovery; for example, in the form of process streams. This can include pre- and tail gas treatment systems, and could handle hazardous components such as sulphurous or chlorinated hydrocarbons. For special requirements, we can offer FTO (flameless thermal oxidation) and we can design systems operating safely on oxygen contents below 5%.

    By Babcock & Wilcox MEGTEC LLC based in De Pere, WISCONSIN (USA).

  • Premium

    Hazardous waste treatment solutions for site remediation

    The contamination of soils as a result of prior chemical production can often be unpredictable and diverse. The majority of such pollutants will require an ex-situ treatment method. Many of our VacuDry units can be used for direct-feeding contaminated soils. To reduce the input amount for thermal treatment, the VacuDry units can also be used in combination with soil-washing plants: In this case, customers only feed the high polluted fractions and screened fines (e.g. below 10 mm), as well as the filter-cake from the soil washing process. However, we are able to handle soil contaminated with mercury, hydrocarbons, PAH, PCB, dioxins, furans, organic-lead compounds and many more. VacuDry plants for on-site ex-situ remediation projects are delivered in a modular design.

    By econ industries GmbH based in Starnberg, GERMANY.

  • Gas Permeation Analysis

    Dissolved Species Analysis Dissolved species analysis employing Hiden's high sensitivity membrane sampling technology for analysis of respiratory gases, hydrocarbons and sulphides is applied to a wide range of application areas including: Ecolological studies in sea water Bio fuel production from algae Pollution monitoring in river, estuary and reservoir waters Soil core analyses Fermentation

    By Hiden Analytical Ltd. based in Warrington, UNITED KINGDOM.

  • PLAZKAT systems for treatment of emissions generated in the production and processing of plastics and polymers

    In connection with the production and processing of polymer materials (manufacturing and cutting plastic film, workingwith thermoplastics, laser cutting plastic) it is necessary to remove pollutants from the ambient air in the working area (e.g.contaminants). In this environment it is usual to install systems for removing organic substances, mainly carboxylic acids, ketones, styrene, hydrocarbons С1-С10 etc.

    By Plasma Air Systems Corporation based in Harju Maakond, ESTONIA.

  • Roadside monitoring

    Traffic, especially in urban locations, is one of the greatest contributors to air pollution. Traffic produces a variety of different pollutants that include particulates, NO2, NO, CO, hydrocarbons and in some cases SO2. The monitoring of roadside pollution can be challenging as often it is difficult to find suitable locations for large air quality monitoring systems and many sites that are available can be too far away to be representative of roadside air pollution.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • PLAZKAT systems for treatment of printing industry emissions

    During production of printed materials the ambient air in the working area absorbs a lot of gaseous pollutants (contaminants) that have so-called `paint smell` - solvents of various kinds (alcohols, ketones, aromatic hydrocarbons, etc.). The presence of these substances in the working area ambient air produces harmful effect at least on the personnel. In addition, solvent emission into the air is penalized in compliance with current regulation.

    By Plasma Air Systems Corporation based in Harju Maakond, ESTONIA.

  • Repair water and Sea ground via SES-Oildissolver

    Oil polluted water and sea bottoms you find on every place of the world. This pollution is often from years before and the total hydrocarbons grow slowly up. It is very easy to clear that problems in harbor, on river, channels, lakes or open sea (gulf of Mexico). SES treat the oil in the sediment and change it to clean bottom, only biological with any side effects to nature (flora and fauna, People). On your request to info@oildissolver.de, we send you demonstration links, results from independent laboratories, viedos and more. Our solution is certified and safe, easy to handle and every company can buy this material to repair their environment. Visit and Cantact us please under: web: www.oildissolver.de mail: info oildissolver.de Heiner Köppen / ceo

    By Oil Dissolver GmbH based in Breddorf, GERMANY.

  • Traffic Emissions Monitoring

    Traffic, especially in urban locations, is one of the greatest contributors to air pollution. Traffic produces a variety of different pollutants that include particulates, NO2, NO, CO, hydrocarbons and in some cases SO2. The monitoring of roadside pollution can be challenging as often it is difficult to find suitable locations for large air quality monitoring systems and many sites that are available can be too far away to be representative of roadside air pollution. Roadside pollution concentrations can change quickly as types and volume of traffic changes and so instrumentation used must be able to cope with these rapidly changing conditions. Ecotech has established a wide variety of roadside monitoring stations incorporated both into large walk-in style shelters to compact monitoring shelters. Our solutions can be tailored to your needs. Ecotech`s compact solution uses a compact monitoring shelter fitted out with a variety of analyzers and particulate monitors. These analyzers offer fast response, minimal maintenance and are widely used for roadside monitoring.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Airport Environmental Monitoring

    Water pollution from airport run-off is increasingly coming under public and government scrutiny. As environmental regulations tighten, the ability to monitor for aviation fuel contamination from runway run-off has become essential.

    Monitoring sites at airports can be extremely challenging often with no power or telephone lines available and with limited access for maintenance. Chelsea’s robust UviLux Hydrocarbon Sensor with its low power consumption and high accuracy is ideally suited for this application. Installed at various locations around the airport, deployed with it’s own integrated anti-biofouling system, utilising the GSM network, the monitoring sites send data to a secure ftp site, where any internet enabled device can access the data. In this way the systems act as any early warning system allowing any hydrocarbon discharge to be detected in real-time.

    Optional environmental monitoring features include remote control to allow the user to turn equipment on and off, change the sample rate and detection range. There is also a facility to allow SMS text and email alarm notifications triggered by user-defined set-points together with customised web pages, data displays and automated data downloads via an ftp server.

    Airport runoff can contain high concentrations of various pollutants, in particular polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs), the environmental levels of which have to be monitored. An understanding of the magnitude of contamination due to airport runoff water is important for the effective management of airport infrastructure. Chelsea’s robust UviLux Hydrocarbon Sensor with its low power consumption and high accuracy is ideally suited to the airport environment.

    By Chelsea Technologies Group based in West Molesey, UNITED KINGDOM.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you