Only show results in Virginia? Ok

hydrocarbons analyzer Applications

  • Premium

    Measurement of methane and non-methane hydrocarbons for environmental air quality.

    The Model 8900 Methane/Non-Methane Analyzer provides direct measurement of Methane and Non-Methane Hydrocarbons. This instrument is utilized in ambient air monitoring networks around metropolitan areas, fence-line monitoring at industrial plants and hazardous waste sites, and in the production of high purity industrial gases. Methane is a naturally occurring gas generated from the decomposition of biological materials and industrial activity. Since Methane is not considered a pollutant it is the Non-Methane...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    DETERMINATION OF TOTAL PETROLEUM HYDROCARBONS (TPH) IN WATER BY FLUORIMETRIC METHOD

    Total petroleum hydrocarbons (TPH) is a term used to describe a large family of several hundred chemical compounds that originally come from crude oil; the main and most specific part of these compounds are non-polar and slightly polar hydrocarbons of the aliphatic, aromatic and alicyclic structure. These compounds are harmful to humans and animals if absorbed through the skin, ingested, and inhaled thus claiming the analytical control of THP content in water as a global issue. Quantification of TPH in water is...

    By Lumex Instruments Group based in Mission, BRITISH COLUMBIA (CANADA).

  • Premium

    Measuring aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    The Series 8900 BTEX Analyzer provides direct measurement of Benzene, Toluene, Ethylbenzene, and Xylenes in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites. The Series 8900 BTEX Analyzer employs a photoionization detector (PID) as the sensing element. This detector is specific to volatile organic compounds. The Benzene, Toluene, Ethylbenzene, and Xylene`s in the gas sample are physically separated using proprietary GC columns.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Gas analyzers and detectors for the ethanol processing

    Gas chromatographs and hydrocarbon analyzers can be key in adding value to the ethanol production process and protecting the environment from Volatile Organic Compound (VOC)emissions created during the process.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Low level measurement of aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring.

    The Series 8900 BTEX Analyzer with a high-sensitivity PID provides direct low level measurement of Benzene, Toluene, Ethylbenzene, and Xylene`s in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to...

    By ENVEA based in Poissy, FRANCE.

  • Alkane (hydrocarbon) gas measurement for mudlogging in oil & gas drilling rigs

    The need for operator and maintainance intensive gas chromatograph (GC) analyzers was eliminated. Customer can now deploy all-optical, unattended sensor system for monitoring the composition of hydrocarbon gases (C1-C5) exiting the well bore which provides crucial information about the drilling formation that would save time and money.

    By MKS Instruments, Inc. based in Andover, MASSACHUSETTS (USA).

  • Premium

    UV fluorescence technology for raw water intake monitoring industry

    Naturally occurring organics in raw water are typically removed with chemicals. Total Organic Carbon (TOC) analyzers in the water treatment system can alert technicians when generic organic material is present but cannot differentiate between natural organics, such as algae or decomposed plant matter, and hydrocarbons. Using UV fluorescence technology, a properly configured TD-4100XD can alert operators to upsets caused by hydrocarbons such as gasoline, diesel, fuel oil, and crude oil.

    By Turner Designs Hydrocarbon Instruments, Inc. based in Fresno, CALIFORNIA (USA).

  • Premium

    Measurement of diacetyl in ambient air to monitor workplace exposure limits.

    The Series 8900 Diacetyl Analyzer provides direct measurement of Diacetyl in ambient air. This instrument is utilized for environmental monitoring and to monitor workplace exposure limits. The Series 8900 Analyzer for Diacetyl employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

    The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

    The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of naphthalene in ambient air to monitor workplace exposure limits & at remediation & Superfund sites

    The Series 8900 Naphthalene Analyzer provides direct measurement of Naphthalene in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits and at remediation and Superfund sites. The Series 8900 Naphthalene Analyzer employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring

    The Series 8900 Hydrogen Sulfide and Carbon Disulfide Analyzer provides direct measurement of H2S and CS2 in ambient air. This instrument is utilized for continuous emission monitoring. The Series 8900 H2S and CS2 Analyzer employs a Photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    ppm Measurement of Oil in Water for the Petrochemical Industry

    Measuring the oil content in water or soil is a specialty of Wilks Enterprise. InfraCal TOG/TPH Analyzers provide on-site ppm measurements to help ensure upstream or downstream wastewater complies with discharge permits to avoid potentially costly fines. There are over 3,000 InfraCal TOG/TPH Analyzers in operation today around the world measuring the oil and grease levels in produced water on drilling platforms, oil content in FRAC water, hydrocarbons in wastewater effluents from refineries, and TPH in soil at...

    By Spectro Scientific based in Chelmsford, MASSACHUSETTS (USA).

  • Premium

    TPH in Soil Remediation

    InfraCal TOG/TPH Analyzers allow for TPH (Total Petroleum Hydrocarbons) in soil testing at remediation sites such as leaking underground storage tanks and produced water evaporation ponds. Site managers can avoid having costly soil remediation equipment sit idle while waiting for off-site lab results. Sampling requires a few simple steps that can be performed by non-technical personnel. The soil is mixed with the extraction solvent, shaken, filtered, and then presented to the InfraCal Analyzer for measurement....

    By Spectro Scientific based in Chelmsford, MASSACHUSETTS (USA).

  • Applications Testing PAHs in Soil

    Sitelab's UVF-3100D analyzer is used to test soils for polycyclic aromatic hydrocarbons. PAHs are abundant in coal tars, coal ash, creosote and fuel oils.

    By Sitelab Corporation based in West Newbury, MASSACHUSETTS (USA).

  • Contaminated Soils with Diesel Fuel and Heating Oils

    Sitelab's UVF-3100D is used to test soil to help investigate and clean up sites contaminated by above ground or underground storage tanks (USTs). Soils can be analyzed for extended diesel range organics (EDRO) or extractable petroleum hydrocarbons (EPH). Results correlate well to confirmatory lab methods.

    By Sitelab Corporation based in West Newbury, MASSACHUSETTS (USA).

  • Ambient Monitor Gas Calibration with Ozone Generators

    EnvironicsĀ® Ambient Monitor Calibrator with Ozone Generators facilitate dynamic calibration of ambient air analyzers. These instruments automatically perform zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, O3, hydrocarbons and other gases of interest. All ozone generators are factory calibrated using a NIST traceable ozone standard. The Series 6100, Series 6103 and Series 9100 all meet or exceed U.S. Environmental Protection Agency requirements.

    By Environics, Inc. based in Tolland, CONNECTICUT (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you