hydrocarbons measuring Applications

  • Premium

    Measurement of methane and non-methane hydrocarbons for environmental air quality.

    The Model 8900 Methane/Non-Methane Analyzer provides direct measurement of Methane and Non-Methane Hydrocarbons. This instrument is utilized in ambient air monitoring networks around metropolitan areas, fence-line monitoring at industrial plants and hazardous waste sites, and in the production of high purity industrial gases. Methane is a naturally occurring gas generated from the decomposition of biological materials and industrial activity. Since Methane is not considered a pollutant it is the Non-Methane hydrocarbons that are of primary concern.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of C1-C5 hydrocarbons for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed sample volume is carried to the pre-cut column. Backflush of the pre-cut column is timed from sample injection so that only C1-C5 hydrocarbons are eluted from the pre-cut column to the analytical column. C6+ hydrocarbons on the pre-cut column are then vented. C1-C5 hydrocarbons are separated on the analytical column and elute to the flame ionization detector (FID) for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measuring aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    The Series 8900 BTEX Analyzer provides direct measurement of Benzene, Toluene, Ethylbenzene, and Xylenes in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites. The Series 8900 BTEX Analyzer employs a photoionization detector (PID) as the sensing element. This detector is specific to volatile organic compounds. The Benzene, Toluene, Ethylbenzene, and Xylene`s in the gas sample are physically separated using proprietary GC columns.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Alkane (hydrocarbon) gas measurement for mudlogging in oil & gas drilling rigs

    The need for operator and maintainance intensive gas chromatograph (GC) analyzers was eliminated. Customer can now deploy all-optical, unattended sensor system for monitoring the composition of hydrocarbon gases (C1-C5) exiting the well bore which provides crucial information about the drilling formation that would save time and money.

    By MKS Instruments, Inc. based in Andover, MASSACHUSETTS (USA).

  • Premium

    Low level measurement of aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring.

    The Series 8900 BTEX Analyzer with a high-sensitivity PID provides direct low level measurement of Benzene, Toluene, Ethylbenzene, and Xylene`s in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement solution for breathing gas analysis

    The quality of compressed breathing gases for aircraft, diving and marine has very tight limits imposed by bodies such as NATO and national bodies such as MOD. The test requirements are for contaminants such as CO, CO2, Total VOC, CFCs and halogenated hydrocarbons, as well as H2O and O2 content.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to fixe or mobile ambient air quality monitoring laboratories. The VOC72M is fitted with a PID detector new generation, much more sensitive, more stable and whose lamp does not need to be cleaned; the analyzer integrates flow control fittings a 3 levels security system built on and uses only one gas (nitrogen). This robust and low maintenance instrument performs all the functions (sampling, analysis and data management) in a simple and completely autonomous mode. It is a particular

    By Environnement S.A based in Poissy, FRANCE.

  • Premium

    Impurities measurement in gaseous carbon dioxide

    This solution is dedicated to the measurement of impurities (e.g hydrocarbons, sulfur compounds...) in gaseous carbon dioxide.

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    ppm Measurement of Oil in Water for the Petrochemical Industry

    Measuring the oil content in water or soil is a specialty of Wilks Enterprise. InfraCal TOG/TPH Analyzers provide on-site ppm measurements to help ensure upstream or downstream wastewater complies with discharge permits to avoid potentially costly fines. There are over 3,000 InfraCal TOG/TPH Analyzers in operation today around the world measuring the oil and grease levels in produced water on drilling platforms, oil content in FRAC water, hydrocarbons in wastewater effluents from refineries, and TPH in soil at remediation sites.

    By Spectro Scientific based in Chelmsford, MASSACHUSETTS (USA).

  • Premium

    Measurement of diacetyl in ambient air to monitor workplace exposure limits.

    The Series 8900 Diacetyl Analyzer provides direct measurement of Diacetyl in ambient air. This instrument is utilized for environmental monitoring and to monitor workplace exposure limits. The Series 8900 Analyzer for Diacetyl employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Diacetyl and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. The Diacetyl is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of naphthalene in ambient air to monitor workplace exposure limits & at remediation & Superfund sites

    The Series 8900 Naphthalene Analyzer provides direct measurement of Naphthalene in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits and at remediation and Superfund sites. The Series 8900 Naphthalene Analyzer employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Naphthalene and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Naphthalene is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring

    The Series 8900 Hydrogen Sulfide and Carbon Disulfide Analyzer provides direct measurement of H2S and CS2 in ambient air. This instrument is utilized for continuous emission monitoring. The Series 8900 H2S and CS2 Analyzer employs a Photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the H2S, CS2, and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. H2S and CS2 are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

    The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Formaldehyde and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Formaldehyde is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

    The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Acrylonitrile and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Acrylonitrile is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of C1-C5 with carbon dioxide for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons and Carbon Dioxide required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed sample volume is carried to the pre-cut column. Backflush of the pre-cut column is timed from sample injection so that only C1-C5 hydrocarbons are eluted from the pre-cut column to the analytical column. C6+ hydrocarbons on the pre-cut column are then vented. Then a third column is used in conjunction with a second 10-port valve for individual analysis of methane. C1-C5 hydrocarbons are separated on the analytical column and elute to the flame ionization detector (FID) for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Environmental monitoring solution for cement industry

    Measurement of particulates, SO2, NOx, hydrocarbons and greenhouse gas emissions from the cement manufacturing industry requires careful selection of instrumentation. Ecotech offers a complete monitoring solution tailored to this industry.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Chromatography systems for petrochemical industries

    The measurement of permanent gases, light hydrocarbons, sulfur compouds etc. in petrochemicals is important to petrochemical industry. Dikma offers a full range of products to measure these basic parameters.

    By Dikma Technologies Inc. based in Lake Forest, CALIFORNIA (USA).

  • Environmental monitoring solution for mineral processing

    Measurement of particulates, SO2, NOX, CO, hydrocarbons and greenhouse gas emissions from the mineral process industries requires careful selection of instrumentation. Ecotech offers a complete monitoring solution tailored to this industry.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Premium

    TPH in Soil Remediation

    InfraCal TOG/TPH Analyzers allow for TPH (Total Petroleum Hydrocarbons) in soil testing at remediation sites such as leaking underground storage tanks and produced water evaporation ponds. Site managers can avoid having costly soil remediation equipment sit idle while waiting for off-site lab results. Sampling requires a few simple steps that can be performed by non-technical personnel. The soil is mixed with the extraction solvent, shaken, filtered, and then presented to the InfraCal Analyzer for measurement. Features include: - Results in under 15 minutes, including extraction ¨ Detect levels as low as 10 ppm ¨ Portable, rugged, lightweight, easy-to-use ¨ Battery operable ¨ Ideal for field or laboratory applications ¨ Factory calibration available

    By Spectro Scientific based in Chelmsford, MASSACHUSETTS (USA).

  • Moisture Monitoring for Natural Gas & LNG

    The presence of moisture in high-pressure natural gas from production wells causes pipelines and associated valves to freeze. High moisture content also leads to the formation of hydrates of the liquid hydrocarbons present, thus causing further difficulties. The moisture content of the gas also adversely affects the calorific value of the gas, thus lowering the quality and value of the product. Moisture is therefore measured at the point of extraction, at export stations, at gas storage locations and in the transmission grid. As natural gas often contains high levels of contaminants, more complex systems are required to maintain instrument performance over prolonged periods and to verify data collected in spot-check moisture analysis.

    By Moisture Control & Measurement Ltd based in Wetherby, UNITED KINGDOM.