Only show results in Virginia? Ok

hydrogen analyzer Applications

  • Premium

    Online monitoring solutions for determination of hydrogen in hydrogen feed

    Levels of of hydrogen in the hydrogen feed of the HCl burner are reliably measured and controlled by means of AppliTek’s thermal conductivity analyzer system. The analyzer system is suited for use in hazardous environments and meets ATEX or NEC500 compliance standards.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Hydrogen Fluoride (HF) Monitoring in Air

    Hydrogen Fluoride (HF) is a colorless gas that is used extensively in industrial applications. Fluoride monitoring is especially needed for aluminum plants that need to convert HF into fluorine for use in their processes. Any HF that escapes is a cost to the plant, so an HF analyzer is essential to keep track of and prevent the losses.

    By Unisearch Associates Inc. based in Concord, ONTARIO (CANADA).

  • Premium

    Online monitoring solutions for determination of hydrogen in gas vent

    Levels of of hydrogen in the gas vent of the HCl burner can be measured by means of AppliTek’s thermal conductivity analyzer system. The analyzer system is suited for use in hazardous environments and meets ATEX or NEC500 compliance standards.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Premium

    Online monitoring solutions for determination of oxygen in hydrogen outlet

    The determination of oxygen in hydrogen is a safety critical measurement to keep the hydrogen mixture below explosion limits during chlorine electrolysis. AppliTek’s analyzer system is engineered to detect oxygen in an early stage and safeguard the compression process, with a small footprint allowing easy integration in any production site.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Premium

    Online monitoring solutions for determination of oxygen in hydrogen feed

    AppliTek’s gas analyzer system allows to monitor and control precisely oxygen levels in the hydrogen feed of the HCl burner. The analyzer system can be equipped with either an electrochemical cell, by alternating Pressure Paramagnetic or with a Tunable Diode Laser (TDL).

    By AppliTek NV based in Nazareth, BELGIUM.

  • Premium

    Online monitoring solutions for determination of hydrogen in dry chlorine

    Levels of hydrogen in dry chlorine are monitored in hydrochloric acid synthesis by means of AppliTek’s multi-wavelength IR analyzer system. With increasing concerns over safety and efficiency in the chlorine manufacturing processes, AppliTek has investigated the use of proprietary on-line analyzer systems to monitor and control the HCl synthesis. Each of these on-line analyzer systems has been selected to control a specific part of the burner, by using techniques such as multi-wavelength infrared, thermal...

    By AppliTek NV based in Nazareth, BELGIUM.

  • Premium

    Online monitoring solutions for fast determination of hydrogen in dry chlorine

    Fast determination of hydrogen in dry chlorine provides an early warning system against elevated levels of hydrogen, thereby protecting the chlorine production plant against hydrogen explosion incidents. AppliTek’s analyzer system for fast determination of hydrogen in dry chlorine can be considered as Best Available Technology (BAT). However, it can never replace a system for determination of hydrogen in wet chlorine since it meets other needs in process control than those for wet chlorine. Even a tiny...

    By AppliTek NV based in Nazareth, BELGIUM.

  • Premium

    Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring

    The Series 8900 Hydrogen Sulfide and Carbon Disulfide Analyzer provides direct measurement of H2S and CS2 in ambient air. This instrument is utilized for continuous emission monitoring. The Series 8900 H2S and CS2 Analyzer employs a Photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Gas monitoring instruments and systems for stack testing according to EPA test method 320

    The United States Environmental Protection Agency (EPA) has two stack testing methods for FTIR gas analyzers. Method 320 is an FTIR method for measuring wide range of organic and inorganic pollutants. Method 321 is a specific version for measuring hydrogen chloride HCl at cement kilns producing Portland cement. These methods define a quality assurance and control processes for verifying the accuracy of the results. The requirements for analytical equipment and software are defined on 40 CFR Part 60 Appendix B...

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Online monitoring solutions for determination of ferric chloride in liquid phase EDC

    The purpose of determining hydrogen chloride in liquid EDC (ethylene dichloride) is to protect EDC against corrosion by HCl during transport or storage. For all other analytical solutions in the chlorination process, please browse the On-line Analyzers Suite under Products & Solutions.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Premium

    Online monitoring solutions for the determination of acidity in vinyl chloride

    Acidity in vinyl chloride can be quantified by measurement of hydrogen chloride (HCl) levels, serving as a quality measure and preventing corrosion of the storage and handling equipment. For this reason it is recommended to monitor and control HCl by means of AppliTek’s UPA Universal Process Analyzer technology.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Premium

    Online monitoring solutions for the determination of chlorine in hydrochloric acid

    Chlorine levels in liquid hydrochloric acid (HCl) are precisely and safely monitored by means of AppliTek’s EZ-HCl process analyzer. On-line measurement of chlorine in liquid HCl guarantees the purity of the end product. An additional possible reason for the measurement is that chlorine is an indicator for the amount of excess hydrogen in the synthesis of hydrochloric acid.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Premium

    Gas Detection Solutions for Aluminium

    Primary aluminium smelting generates large amounts of hydrogen fluoride gas (HF). Worker safety and ambient air quality concerns require that HF be monitored at several locations in smelters. Traditionally, a variety of chemical sampling methods have been used for HF monitoring in and around smelters. However, these methods are labour intensive and require ongoing maintenance and consumables. During the past decade, laser based HF analyzers have been replacing the traditional methods. Laser analyzers are compact,...

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Premium

    Online monitoring solutions for the determination of chlorine in dry chlorine

    Levels of chlorine in dry chlorine in hydrochloric acid synthesis are monitored by means of AppliTek’s multi-wavelength UV analyzer system. Hydrochloric acid or HCl is one of the primary products of the chlor-alkali industry and commonly produced by the exothermic reaction of hydrogen and chlorine inside a burner. With increasing concerns over safety and efficiency in the chlorine manufacturing processes, AppliTek has investigated the use of proprietary on-line analyzer systems to monitor and control HCl...

    By AppliTek NV based in Nazareth, BELGIUM.

  • Gas analysis & monitoring systems for biogas analysis

    “Biogas” means a mixture of various types of gas (mostly methane) produced by bacterial fermentation in anaerobic conditions(absence of oxygen) of organic residues from waste, decaying plant, carcasses in putrescence. The analyzers of biogas by Infrared cells carry out the continuous analysis of CH4, O2, CO2, H2S and NH3. The whole process sees the decomposition of organic material by some types of bacteria, producing carbon dioxide, molecular hydrogen and methane(methane conversion of organic compounds...

    By ETG Risorse e Tecnologia S.r.l. based in Montiglio, ITALY.

  • Precision moisture analysis instruments for rapid solids testing for pulp and paper

    Durable, reliable analysis for black liquor. Black liquor is a difficult substance to work with. It’s caustic, it’s toxic, and it emits poisonous gases such as hydrogen sulfide. But the efficient use of black liquor is critical to the profitable operation of any pulp and paper mill. In order to use black liquor efficiently, you need to test it for solids. Make sure your solids analyzer is up to the task.

    By AMETEK Brookfield based in Chandler, ARIZONA (USA).

  • Analytical instrumentation for the natural gas industry

    Natural gas is a hydrocarbon gas mixture consisting primarily of methane(CH4) , but commonly includes varying amounts of other higher alkanes and usually small amounts of impurities like water vapor (H2O), hydrogen sulfide(H2S), carbon dioxide(CO2), and nitrogen (N2 ) and others. Natural gas must be processed from the impurities before can be used as a fuel. Five stages are often required to convert raw natural gas into fuel gas pipelined to the end user markets: extraction and gathering, gas purification,...

    By Focused Photonics Inc. (FPI) based in Hangzhou, CHINA.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you