Only show results available in Virginia? Ok

hypochlorite dosing Applications

  • Premium

    Dosing pumps for water and wastewater treatment industry

    Peristaltic pumps are proven performers in water and waste treatment solving problems including: Dosing and metering treatment chemicals and reagents including ferric chloride (“Ferric”), sodium hypochlorite (“Hypo”), chlorine water, lime (Kalic or Kalkmilch), caustic soda, powder activated carbon and polymers, sludge transfer, filter press feeds.

    By Verderflex Peristaltic Pumps - part of the Verder Group based in Castleford, UNITED KINGDOM.

  • Premium

    Albin peristaltic`s pumps for water treatment

    Pumping / transfert / dosing of sewage thickened, sludge dewatered, sludge clarifier, waste activated sludge, digested sludge, primary sludge, lime milk, raw sludge, sodium hypochlorite, ferric chloride, sodium bisulphite, fluoride, polymers, aqueous am­monia, potassium permanganate, caustic soda.

    By Albin Pump SAS based in Goteborg, SWEDEN.

  • Odor Scrubbers Applications with Hydrogen Peroxide

    Hydrogen Peroxide as a Replacement for Sodium Hypochlorite Hydrogen peroxide may be used in both mist scrubbers and packed tower scrubbers as a replacement for sodium hypochlorite (bleach). Like bleach, the process involves two concurrent mechanisms: 1) absorption of the odors (H2S) into the alkaline scrubbing solution; and 2) oxidation of the absorbed sulfide in solution. Step 1: H2S + NaOH → NaSH + H2O Step 2: 4H2O2 + H2S → H2SO4 + 4H2O Typical dose ratios are 5 parts H2O2 per part H2S or, when used in place of bleach, one gallon 50% H2O2 for every 10 gallons of 15% sodium hypochlorite (NaOCl). This generally translates into a break-even cost scenario. Sufficient caustic soda (NaOH) is added to maintain a pH of 10.0 - 10.5 in the scrubbing solution. There is also in practice a process which uses H2O2 in series with bleach to scrub composting odors. This process relies on a series of three packed tower scrubbers: the first is a pH neutral water wash (to remove ammonia and amine odors); the second uses a conventional caustic/bleach solution in which the bleach is purposely overdosed (to oxidize the complex organic sulfur odors); and the third uses a caustic/H2O2 solution (to remove the unreacted chlorine vapors carried over from the second stage). H2O2 + HOCl → HCl + H2O + O2 Typical dose ratios are 0.5 parts H2O2 per part hypochlorite (OCl-), with sufficient caustic soda (NaOH) added to maintain a pH of 8.5 in the scrubbing solution.

    By USP Technologies based in Atlanta, GEORGIA (US) (USA).