Only show results available in Virginia? Ok

level monitoring system Applications

  • Premium

    Street-level monitoring

    To measure the air quality in a city is a challenge. A large number of gaseous components need to be measured with high accuracy. The monitoring site needs to be representative for the city and the system has to be easy to maintain and calibrate.

    By Opsis AB based in Furulund, SWEDEN.

  • Continuous Emissions Monitoring Calibration Systems (CEMCS)

    The Environics Series Continuous Emissions Monitoring Calibration Systems (CEMCS) have been used in CEM vans and laboratories for over twenty years. They meet or exceed the performance requirements of the United States EPA 40 CFR Part 51 Method 205 Appendix M. Our systems are custom built, computerized, mass flow controller based gas calibration systems which allow you to dilute a single high concentration cylinder of span gas to low levels for the calibration of gas analyzers.

    By Environics, Inc. based in Tolland, CONNECTICUT (USA).

  • Premium

    Gas analysis & monitoring system for greenhouse gases analysis

    The rising levels of manmade greenhouse gases (GHGs) in the atmosphere and their resulting impact on climate is now one of the single biggest technological and environmental challenges facing the world. This makes intensified monitoring of these gases more critical than ever in order to better quantify the role of the numerous natural and manmade sources, sinks and buffers involved in the cycles of GHGs. It also enables us to objectively audit GHG fluxes at the factory, city, country and continental level. Such objective auditing is ultimately essential to facilitate effective enforcement and compliance with any regulations, laws, treaties and trading agreements based on GHG metrics such as carbon footprints.

    By ETG Risorse e Tecnologia based in Montiglio, ITALY.

  • Real-time In-situ Effluent Monitoring

    The UviLux BOD Indicator enables in-situ, real-time, reporting of BOD within both natural water systems and water processing plants. The monitor detects fluorescent proteins that are inherent within sewage and slurry and provides an output in BOD equivalent units. The principle behind the measurement is the excitation of Tryptophan-like fluorescence within UV wavelength band, which has been shown to correlate with both BOD and bacterial contamination. With complete flexibility of deployment methodology, the UviLux BOD Indicator can be applied to both water supply and water recovery processing plants. For water supply processing, the UviLux BOD Indicator can be applied at the front end to the water intake to provide alarm of any contaminated water entering the plant. Applications within Waste Water Treatment Works can include monitoring of effluent levels at the final outflow point (into rivers and coastal areas) as well as the primary, secondary & tertiary stages, the data potentially feeding into energy saving systems to optimise process performances. The CTG UviLux BOD Indicator in-situ fluorometer can also be used within pipe and channel networks to test for incidences of black water and grey water cross-over.

    By Chelsea Technologies Group based in West Molesey, UNITED KINGDOM.

  • Premium

    Mercury monitoring for mercury flux measurement

    The Tekran 2537 has been used in numerous published studies to measure the deposition or evasion of mercury from natural or contaminated surfaces (i.e. flux measurements). It is anticipated that many mercury flux measurements will be needed in the future to assess the impact of climate change on mercury cycling in the environment. There are two basic ways to do mercury flux measurements. First, the dynamic flux chamber method utilizes a custom enclosure, with controlled air flow, to measure the inlet and outlet concentration over a selected surface to determine the flux over time. Alternatively, the micrometeorological gradient method uses measured concentrations at two levels above a surface. The perfect tool for both flux measurement methods is the Tekran 1110 Two Port Sampler, so the Tekran 2537 can automatically switch between two distinct sampling points. Ask us how we can help you setup a mercury flux system.

    By Tekran Instruments Corporation based in Knoxville, TENNESSEE (USA).

  • Premium

    Meteorological systems for weather sensors, components & accessories

    At the core of Climatronics’ meteorological monitoring systems is a complete complement of weather sensors, components and accessories. These weather sensors cover the range of each variables’ environmental range, and can be provided with a level of accuracy that matches each user’s requirements.

    By Climatronics Corporation based in Bohemia, NEW YORK (USA).

  • Premium

    Measurement solution for to multi-stream by-pass system

    A large pharmaceutical plant runs a Thermal Oxidiser on plant to incinerate their solvent-containing gas streams before emission. When the oxidiser is offline, then the plant must monitor the release of solvent to the atmosphere. A ProtIR 204C fixed monitoring system was installed that continually measures 24 plant solvents, including Acetone, Cyclohexane, DCM, DMF, IPA, MIBK, Toluene and THF. Given the high levels that are possible, the system has an active dilution system, reducing the concentration of the measured gas in the analyser to levels that can be analysed simply. Chemometric modelling enables interferences from the overlapping absorption spectra to be accounted for, ensuring accurate analysis of all 24 gases.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Gas monitoring instruments and systems for process NOx measurement

    Nitric acid HNO3 is an important intermediate reagent for production of several important end products, such as fertilizers, explosives, dyestuffs/pigments, pesticides, pharmaceuticals, photographic materials, plastics, and synthetic fibers. At nitric acid manufacturing plants, the Gasmet™ FTIR Gas Analyzer can be used to measure several gaseous components from the process stream for purposes of process control. A single system can be used to measure the high levels of nitrogen monoxide NO and nitrogen dioxide NO2, as well as water vapor H2O, nitrous oxide N2O, carbon monoxide CO, carbon dioxide CO2 and ammonia NH3. The fixed installation products for these purposes are the Gasmet™ CEM II measurement system, and the Gasmet™ FCX Gas Analyzers, both of which utilize the FTIR measurement technique for simultaneous multicomponent analysis of the sample gas.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Measurement solution for ambient air workplace monitoring

    Protea can supply fixed workplace monitoring systems that can measure single or multi-points about the workplace. Specifically designed analytical systems can ensure detection limits down to ppb levels can be achieved for multiple gases with a single instrument. Controlling software can run automatically, providing instantaneous or time-weighted average readings.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Noise Monitoring for Construction / Noise Monitoring for Demolition

    Cirrus Environmental can supply a range of noise measurement options for construction and demolition noise applications. These range from handheld sound level meters for taking noise measurements through semi-permanent noise monitors to permanently installed noise monitoring systems, all designed to be fully weather protected for reliable long term operation.

    By Cirrus Environmental based in Peterborough, UNITED KINGDOM.

  • Noise monitoring for the mining industry

    The management of noise from mining operations is recognized as a fundamental responsibility of the mining industry. Implementing a noise management system that includes noise surveys, day and night noise mitigation, and some level of noise monitoring is a primary function that is required to meet environmental impact standards in most locations.

    By Larson Davis, a division of PCB Piezotronics based in Depew, NEW YORK (USA).

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to fixe or mobile ambient air quality monitoring laboratories. The VOC72M is fitted with a PID detector new generation, much more sensitive, more stable and whose lamp does not need to be cleaned; the analyzer integrates flow control fittings a 3 levels security system built on and uses only one gas (nitrogen). This robust and low maintenance instrument performs all the functions (sampling, analysis and data management) in a simple and completely autonomous mode. It is a particular

    By Environnement S.A based in Poissy, FRANCE.

  • Premium

    Air sampling & monitoring systems for biomedical, chemical & pharmaceutical industry

    HI-Q Environmental Product Company provides air sampling instrumentation & systems for several niche applications in a number of disciplines in the broad area of `Life Sciences`. In the Biomedical, Chemical, & Pharmaceutical industries, HI-Q has marketed instrumentation for certain applications for many years. Our ambient, in-door breathing level air samplers, commonly known in the industry as `Goose-Neck` or `Giraffe` air samplers have been instrumental in analyzing workplace exposure. HI-Q has also developed accurate pre & post heap filtration stack sampling systems to aid laboratories in inventory control & atmospheric exposure monitoring for chemicals such as Radio Iodine.

    By HI-Q Environmental Products Company based in San Diego, CALIFORNIA (USA).

  • Premium

    Measurement solution for QAL2 EN 14181

    BS EN 14181 is a quality assurance standard relevant to plants operating under the Large Combustion Plant (LCPD) and Waste Incineration (WID) Directives. Quality Assurance Level 2 (QAL2) of this standard involves the parallel testing of the plant automated measurement systems (AMS) against a certified test house, making measurements with a comparative standard.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Emissions Monitoring for Cement Plants

    Opsis provides state-of-the-art monitoring equipment, fully meeting the high standards of monitoring performance and reliability that the cement industry requires. The Opsis in situ systems are designed to withstand environments with high particulate levels and high temperatures.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Measurement solution for high NH3 monitoring from wastewater

    Protea was asked to supply a high level ammonia (NH3) measurement system for a waste water treatment plant. The reflux drums at the inlet to two ammonia stripping towers needed to be measured continuously. Protea designed a solution based around our Solus TDLAS analyser platform and a high level dilution system. The Solus analyser was configured for NH3 measurements in the range 0-500ppm. A dilution system incorporating special dilution probe and 19` control panel was installed before the analyser. This gave a dilution level of 600:1, enabling the NH3 analyser to measure in the range 0-30% Volume.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Airport Environmental Monitoring

    Water pollution from airport run-off is increasingly coming under public and government scrutiny. As environmental regulations tighten, the ability to monitor for aviation fuel contamination from runway run-off has become essential.

    Monitoring sites at airports can be extremely challenging often with no power or telephone lines available and with limited access for maintenance. Chelsea’s robust UviLux Hydrocarbon Sensor with its low power consumption and high accuracy is ideally suited for this application. Installed at various locations around the airport, deployed with it’s own integrated anti-biofouling system, utilising the GSM network, the monitoring sites send data to a secure ftp site, where any internet enabled device can access the data. In this way the systems act as any early warning system allowing any hydrocarbon discharge to be detected in real-time.

    Optional environmental monitoring features include remote control to allow the user to turn equipment on and off, change the sample rate and detection range. There is also a facility to allow SMS text and email alarm notifications triggered by user-defined set-points together with customised web pages, data displays and automated data downloads via an ftp server.

    Airport runoff can contain high concentrations of various pollutants, in particular polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs), the environmental levels of which have to be monitored. An understanding of the magnitude of contamination due to airport runoff water is important for the effective management of airport infrastructure. Chelsea’s robust UviLux Hydrocarbon Sensor with its low power consumption and high accuracy is ideally suited to the airport environment.

    By Chelsea Technologies Group based in West Molesey, UNITED KINGDOM.

  • Premium

    Online Monitoring for the Drinking Water Industry

    AppliTek manufactures wet-chemical analyzers specifically designed for measuring on a continuous base the quality indices of drinking water, from raw water intake up to distribution level. Our systems have a small footprint, reduced reagent consumption and show excellent levels of detection in compliance with modern standards.

    On top of that, the delivery of safe water throughout the water cycle will raise the need for efficient monitoring systems detecting in real-time contaminations. `Broadband toxicity`, a non-specific parameter defined by AppliTek, is a prodigiously new and clean technology for safeguarding drinking water.

    By AppliTek NV - Environmental Analysis Division based in Nazareth, BELGIUM.

  • Premium

    Ambient air quality monitoring at airports

    To measure the ambient air quality at airports is a challenge. The monitoring site needs to be representative for background levels and not dependant on changes in local traffic. A large number of gaseous components need to be measured with high accuracy and high availability. The OPSIS DOAS system provides the user with a fast system that gives high availability at low cost. The impact of aircraft take-offs and landings can easily be followed on-line. The OPSIS system can also monitor fugitive emissions from other sources at the airport.

    By Opsis AB based in Furulund, SWEDEN.

  • Noise and vibration monitoring for nuclear power industry

    The nuclear industry must increase the availability and reliability of its power stations whilst ensuring that a high level of safety is maintained. The principal weak points in achieving this objective are the industry`s systems and components.

    By ACOEM based in Limonest, FRANCE.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you