mass spectrometer Applications

  • Mass Spectrometer for air consultancy

    Everyone has a responsibility to care for the environment to reduce the levels of pollution, including businesses that daily release emissions into the air and the ground. This is why we provide a full-service environmental testing service to help businesses identify problems and resolve them so they operate in the most environmentally-friendly method possible. We offer air emission testing, emissions monitoring services and stack emissions testing to businesses of all sizes.

    By Custom Stack Analysis, LLC. based in Alliance, OHIO (USA).

  • Thermal Analysis Mass Spectrometry

    Hiden offers optimized interface coupling to a range of thermal analysis systems including: TGA-MS and TGA/DTA-MS systems: Hiden Isochema IGA - intelligent gravimetric analyser, PerkinElmer-TA Instruments- Netzsch- Mettler Toledo- Seteram Calorimetry: Mass spectrometry for simultaneous evolved gas/calirometry analysis. Evolved gas analysis compliments the calorimetric data providing reaction kinetics data and speciation of reaction off gas. Solid Insertion Probe: An integrated solid insertion probe mass spectrometer system for in-situ TPD studies. Hiden Catlab: An integrated microreactor/mass spectrometer for catalyst characterisation.

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Residual Gas Analysis

    Residual Gas Analysis is a general term for the analysis of gas and vapour species in vacuum chambers and vacuum processes. The Hiden RGA series quadrupole mass spectrometers provide for routine, fast, wide dynamic range residual gas analysis, measuring the partial pressures of the species that are critical to vacuum quality and process requirements. Applications include: vacuum chamber leak detection vacuum quality measurement and monitoring virtual leak detection outgassing studies bakeout cycle/vacuum pump down monitoring

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • MBE Desposition Rate Monitoring and Control

    XBS Triple Filter Quadrupoles configured for multiple source monitoring in MBE deposition applications. The custom configured ioniser provides for high stability, high senstivity monitoring of oxides and metals from both k-cell and e-gun sources. MBE monitoring and control. Molecular Beam Studies. Multiple beam source analysis. High Performance RGA. Desorption / Outgassing studies / Bakeout cycles. Chamber / Process gas Contaminants. Hiden XBS mass spectrometers for high precision scientific, process applications and MBE analysis, featuring: High Sensitivity, Enhanced detection from 100% to 5ppb, mass range to 510 amu. Enhanced long-term Stability (less than ±0.5% height variation over 24 h). Crossbeam ion source, beam acceptance through +/- 35° to transverse axis. Ion source control for soft ionisation and appearance potential mass spectrometry. Enhanced sensitivity for high mass transmission,

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Surface Science

    SIMS - for depth profiling, surface composition measurement, and elemental imaging, Hiden's SIMS Workstation provides a complete analytical facility. RGA - The Hiden quadrupole mass spectrometers provide high sensitivity detection capability for the most demanding XHV/UHV vacuum environments. The pulse ion counting detector enables measurement of both positive and negative ions through 7 continuous decades, the integral accumulation mode being used for the capture of discreet particle events. UHV Temperature Programmed desorption studies (TPD) - Hiden Analytical’s 3F/PIC mass spectrometers with pulse ion counting detection are available configured specifically for UHVTPD providing fast, wide dynamic range detection of multiple species, capturing the entire desorption event. The Hiden IDP ion desorption probe is a quadrupole mass spectrometer configured for analysis of low energy ions in electron and photon stimulated desorption studies.

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • End Point Detection

    Hiden Ion Milling Probe – End Point Detector The only dedicated end point determination tool for ion etch control and optimum process quality. End point Analysis. Target Impurity Determination. Quality Control / SPC. Residual Gas Analysis. Leak Detection The IMP is a differentially pumped, ruggedized secondary ion mass spectrometer for the analysis of secondary ions and neutrals from the ion mill process, featuring: High Sensitivity SIMS / MS with Pulse Ion Counting Detector. Triple filter Quadrupole, 300 amu mass range is standard. Differentially Pumped Manifold With Mounting Flange to Process Chamber. Ion Optics with Energy Analyser and integral ioniser. Penning Gauge and interlocks to provide over pressure protection. Data System with integration to the process tool. Stability (less than ±0.5% height variation over 24 h). MASsoft control via RS232, RS485 or Ethernet LAN. Programmable DDE, Parallel Digital I / O, RS232 Scripting Communication

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Catalysis

    Hiden's modular CATLAB offers a wide range of experimental tools for catalyst researchers, from rapid dynamic screening to fully automated precise investigations of active surface chemistry & optimisation of catalytic activity. The CATLAB performs analysis using temperature programmed methods such as TPR/TPO/TPD. Pulse chemisorption is also available with the CATLAB-PCS. The integrated QGA mass spectrometer system provides for quantification of the adsorbed/desorbed species. Physical analyses such as metal surface area, catalyst dispersion and surface acidity/basicity are provided. All CATLAB & mass spectrometer sampling wetted surfaces are designed to have the widest possible compatibility for use with aggressive species. Hiden Analytical’s HPR-20 QIC mass spectrometer is available for coupling to existing catalyst reactors with integral analysis software available for TPD/TPR/TPO quantification. A range of specialized connectors & couplings optimise integration with reactor vessel

    By Hiden Analytical based in Warrington, UNITED KINGDOM.