moisture analyzer Applications

  • Premium

    Water Vapor Permeation Analyzers for Packaging Industry

    For packaging film barriers, the Systech Illinois range of water vapor permeation analyzers offer a wide measurement range with precision temperature, humidity and flow control. These analyzers utilise the Coulometric P2O5 sensor, which is more sensitive and stable than infra-red and does not require calibration. The P2O5 is the primary method for absolute moisture measurement.

    By Systech Instruments Ltd based in Thame, UNITED KINGDOM.

  • Premium

    Biofuel Analyzing for the Bioenergy Industry

    AppliTek has already developed the necessary tools to measure and control on-line the production, in case the futur is in favour of biofuels. For biodiesel, the following quality indices should be monitored, on order to comply with international legislation on biofuel QC:

    Free fatty acids - Calcium & Magnesium - Total Phosphorus - Potassium - Moisture (water content)

    By AppliTek NV based in Nazareth, BELGIUM.

  • Premium

    Measurement of naphthalene in ambient air to monitor workplace exposure limits & at remediation & Superfund sites

    The Series 8900 Naphthalene Analyzer provides direct measurement of Naphthalene in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits and at remediation and Superfund sites. The Series 8900 Naphthalene Analyzer employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Naphthalene and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Naphthalene is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring

    The Series 8900 Hydrogen Sulfide and Carbon Disulfide Analyzer provides direct measurement of H2S and CS2 in ambient air. This instrument is utilized for continuous emission monitoring. The Series 8900 H2S and CS2 Analyzer employs a Photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the H2S, CS2, and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. H2S and CS2 are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of diacetyl in ambient air to monitor workplace exposure limits.

    The Series 8900 Diacetyl Analyzer provides direct measurement of Diacetyl in ambient air. This instrument is utilized for environmental monitoring and to monitor workplace exposure limits. The Series 8900 Analyzer for Diacetyl employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Diacetyl and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. The Diacetyl is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

    The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Formaldehyde and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Formaldehyde is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

    The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Acrylonitrile and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Acrylonitrile is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).