Only show results available in Virginia? Ok

over-exposure Applications

  • Premium

    Industrial Weighing - Over/Under Checkweighing

    When it comes to manual filling, portioning or quality control, factors such as speed, throughput and quality have an important part to play.

    By Mettler - Toledo Int. Inc based in Greifensee, SWITZERLAND.

  • Premium

    Measurement solution for hospital workplace exposure monitoring

    In taking a responsible stance on the exposure of workers to any potentially hazardous gases, there is a need for workplaces using anaesthetic gases, such as hospital operating rooms or research laboratories, to control the level of waste anaesthetic gas in the ambient air.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Measurement of diacetyl in ambient air to monitor workplace exposure limits.

    The Series 8900 Diacetyl Analyzer provides direct measurement of Diacetyl in ambient air. This instrument is utilized for environmental monitoring and to monitor workplace exposure limits. The Series 8900 Analyzer for Diacetyl employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Diacetyl and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. The Diacetyl is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of naphthalene in ambient air to monitor workplace exposure limits & at remediation & Superfund sites

    The Series 8900 Naphthalene Analyzer provides direct measurement of Naphthalene in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits and at remediation and Superfund sites. The Series 8900 Naphthalene Analyzer employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Naphthalene and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Naphthalene is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of methyl bromide in ambient air for monitoring workplace exposure limits in fumigation facilities

    The Series 8900 Methyl Bromide Monitoring System provides an automated, direct measurement of Methyl Bromide in ambient air. This instrument can meet and exceed the requirements for ambient methyl bromide monitoring. It is utilized in fumigation facilities and industrial plants to detect potential worker exposure to methyl bromide, resulting from mechanical failure, human error or product off gassing. Multipoint sampling options allow the analyzer to monitor multiple sample locations for greater coverage.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of ethylene oxide for monitoring workplace exposure limits

    The Series 8900 Ethylene Oxide Analyzer combines the selectivity of gas chromatography with the sensitivity of a Photoionization Detector (PID) providing interference free response to Ethylene Oxide (EtO) at levels below 0.05 ppm. This analytical method is referenced in OSHA`s `Occupational Exposure to Ethylene Oxide: Final Standard` 29 CFR Part 1910. The system documents exposure levels including: time-weighted averages (TWA), short-term exposure limits (STEL) and instantaneous alarms. Areas that are typically monitored include; EtO Sources - gas storage areas, sterilizer doors, aeration doors, and the General Work Area - decontamination, packaging and preparation and sterile product storage areas.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

    The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Formaldehyde and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Formaldehyde is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

    The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Acrylonitrile and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Acrylonitrile is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Air monitoring equipments for workplace and personal exposure monitoring

    Many occupations involve the use of hazardous substances or processes, where pollutants may be ingested, inhaled or absorbed through the skin. General ambient pollutants can also have health implications in otherwise non-hazardous workplaces. Occupational exposure limits regulate many pollutants based on an eight-hour working day. Personal exposure assessments can be made over an eight-hour period (Time Weighted Average (TWA) exposure) using our simple to use monitoring equipment.

    By Gradko International Ltd based in Winchester, UNITED KINGDOM.

  • Premium

    Simultaneous Air Monitoring over Multiple Fixed Sample Paths

    Application: Simultaneous monitoring over multiple fixed sample paths either in-situ, extractive, or open path. Example: HF scrubber inlet, outlet, and stack monitoring in primary aluminum smelter.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you