Only show results available in Virginia? Ok

particle sampling Applications

  • Independent particle characterization services for environmental industries

    Particle size, particle concentration and other physical characterization analyses are critical to many environmental applications. Regulatory agencies in the environmental sphere demand strict compliance to standards and discharge regulations. Physical testing of samples for parameters such as particle size and concentration can give insight to the process control engineer on how effective and compliant a discharge handling system is operating. Particulate loading from both air emissions and waste water discharge are monitored in many industry sectors and PTL testing provides valuable supporting data in this monitoring process.

    By Particle Technology Labs based in Downers Grove, ILLINOIS (USA).

  • Independent particle characterization services for beauty / cosmetics industries

    PTL’s analytical staff has years of experience designing test methods and performing analysis for cosmetic, skin care, fragrance and personal cosmetics_particle_testinghygiene samples. Whether your company needs a third party verification, routine QC confirmation, stability studies or one time testing, PTL will create a project to meet your needs. Applications include the size and shape of cosmetic enhancers (glitter particles for example) in a final product, droplet size from spray nozzles/atomizers and particle size of emulsion particles comprising creams/lotions. In addition, the particle size of powdered cosmetics is of tremendous importance in how they flow, cover and can directly affect their appearance as well as the user’s skin.

    By Particle Technology Labs based in Downers Grove, ILLINOIS (USA).

  • Air Quality Monitoring for the Aerosol Sampling Industry

    MSP’s aerosol instrument products include cascade impactors, virtual-impactor concentrators, personal PM samplers, micro-environmental PM Samplers, condensation particle counters, an asbestos fiber monitor, aerosol generators, electrical ionizers, differential mobility analyzers, laser particle counters and wide range particle spectrometers.

    By MSP Corporation based in Shoreview, MINNESOTA (USA).

  • Premium

    Air quality monitoring

    To estimate the effects of aerosols on health and climate, it is essential to know their chemical composition. Sampling is done using two different types of aerosol collector. The first type are filter collectors that are based on the deposition of suspended particles on surfaces; the second type are powerful aerosol collectors.

    By Metrohm AG based in Herisau, SWITZERLAND.

  • Premium

    PM2.5/PM10 particulate monitoring

    OPSIS provides real-time, flexible monitoring of particulate matter in the ambient air. Particulate matter monitoring with OPSIS, is a cost-effective solution, is ideally suited for use in modern monitoring stations. It can be remote controlled and includes automatic calibration, features that frees time.  The SM200 meets the new regulation for automatic monitoring of PM10 and PM2.5. It also meets the new regulation for particulate matter sampling on filter membranes for further analysis of cadmium, nickel, PAH and other substances.

    By Opsis AB based in Furulund, SWEDEN.

  • Radionuclide Monitoring for Nuclear Power Plants

    The continuing establishment of nuclear power stations around the world pose unique environmental challenges for their operators. Ecotech provides air samplers to nuclear power plants for sampling of radionuclides. A nuclear power plant`s radionuclide monitoring network enables continuous sampling of airborne particles onto sample filters contained within High Volume Air Samplers. These filters are then analysed in a laboratory in order to screen for any radiation releases. The challenge has always been to obtain a sufficiently large volume through the filter in order to exceed the laboratory methods minimum detection limits. Ecotech`s MegaVol Sampler, samples at a flow rate of between 120-150 m3/hr providing a high flow rate in order to collect a sufficient sample mass for laboratory analysis. The MegaVol will maintain volumetric flow rate at a preset volume until the filter is either changed or overloaded. The MegaVol can be equipped with a 3G modem in order to remotely monitor flow rate and other diagnostic parameters such as temperature, pressure and wind speed and direction.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Filtration for Flue Gas Analysis and CEMS

    Three Steps of CEMS: 1st Step: Gas Sampling 2nd Step: Gas conditioning and treatment 3rd Step: Measurement/Calibration In first step, the function is to get sample gas and forward to 2nd step for treatment. During this step, it cannot block the probes and cannot result condensation of moisture. So a filter online back flushing should be equipped in this part. The filters to be used: 1, Filter is used to ensure the stability of system and reduce the maintenance 2, Filtration Grade: usually 2 or 3 micron 3, Temp. is around 0-180 deg C 4, Back flushing gas is heated, impulse flushing 5, Filter Material: Titanium Sintered, SS316L Sintered, PTFE sintered, Ceramic Membrane and so on 2nd Step Gas Treatment: #11;The coarse filters and the liquid particle filters The coarse and fine cartridge can filter the small particles in the gas and acid aerosol things to better protect the instruments. The micron can be 0.1micron, filtration rate can be up to 99.99%, two layers can be 99.9999%

    By Shanghai CMI Environmental Technology Co.,Ltd. based in Shanghai , CHINA.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you