Only show results available in Virginia? Ok

personal air sampling Applications

  • Premium

    Personal air sampling

    Bodily worn equipment and associated accessories and sampling media for undertaking personal air samples onto media which is then further analysed. Used for measuring employees` exposure to dusts, fumes, gases or vapours

    By Casella based in Kempston, UNITED KINGDOM.

  • Air Quality Monitoring for the Aerosol Sampling Industry

    MSP’s aerosol instrument products include cascade impactors, virtual-impactor concentrators, personal PM samplers, micro-environmental PM Samplers, condensation particle counters, an asbestos fiber monitor, aerosol generators, electrical ionizers, differential mobility analyzers, laser particle counters and wide range particle spectrometers.

    By MSP Corporation based in Shoreview, MINNESOTA (USA).

  • Saran Bag application

    Title : Preliminary Sampling Methodology and Analytical Procedures for Ambient Sulfur Hexafluoride, Corporate Author : ARMY MEDICAL ENVIRONMENTAL ENGINEERING RESEARCH UNIT EDGEWOOD ARSENAL MD Personal Author(s) : Luckan,Susan K. ; Cooper,William J. Report Date : JAN 1973 Pagination or Media Count : 23 Abstract : A preliminary evaluation of techniques of sampling and gas chromatographic analysis for low levels of sulfur hexafluoride was conducted to determine the most feasible method for available equipment. Using a Tracor MT-150 gas chromatograph equipped with Nickel 63 electron capture detector and polarized dc voltable, it was possible to detect sulfur hexafluoride at a concentration of 0.06 ppb with a 5A molecular sieve column and nitrogen carrier gas, without preconcentration of the sample. Also, a comparison of glass and Saran sampling materials proved that no detectable loss of the tracer gas resulted with the Saran bags (between 6 ppm and 0.06 ppb SF6

    By Analytical Specialties, Inc. based in Elburn, ILLINOIS (USA).

  • Premium

    Analysis of Isocyanates Using the ASSETâ„¢ EZ4-NCO Dry Sampler

    Isocyanates are used as a raw material to produce a number of products . Personal exposure can occur while the products made with isocyanates are being applied, or when the materials are removed by grinding or thermal degradation. Workers who are exposed to these compounds are at risk for respiratory disorders and asthma. The highly reactive nature of the isocyanate compounds and the low occupational exposure limits put high demands on both sampling and analytical techniques for monitoring of isocyanates in air. We investigated the performance of the LC-MS and LC-MS-MS methods in the analysis of isocyanates using the new ASSETâ„¢ EZ4-NCO Dry Sampler. We found that the analytical method can successfully reach the quantitation limit for most isocyanates of 5 ng/mL in the final sample when LC-MS-MS analysis was used and the quantitation limit of 10 ng/mL when LC-MS analysis was used. All 11 compounds were well-resolved chromatographically using a 15 cm Ascentis Express C18 column.

    By Sigma-Aldrich Co., LLC based in Bellefonte, PENNSYLVANIA (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you