reference standard Applications
-
Premium
Monitors and analysers for Calibration industry
To ensure high-precision performance from temperature measurement devices, reliable calibration is required. This can be carried out on site or under laboratory conditions, using primary or reference standard sources. Primary calibration sources are traceable to National Standards via a certified probe ...
By AMETEK Land Instruments International Ltd based in Dronfield, UNITED KINGDOM.
-
Dust monitoring of exhaust gases from manufacturing processes
for particular applications, is proportional to dust concentration and when calibrated against standard reference measurements, this can be presented as a reading in ...
By Dynoptic Systems Ltd - ACOEM Group based in Banbury, UNITED KINGDOM.
-
Industrial monitoring solutions for the dust monitors areas
For large combustion plants and power plants we offer the DCEM 2100 particulate monitor. This monitor is certified to EN 15267 part 3 QAL 1 for all industrial processes including waste incineration. It offers outputs in Transmission, Opacity and mg/m3 (when calibrated against a Standard Reference Method). The ...
By Codel - a Forbes Marshall company based in Bakewell, UNITED KINGDOM.
-
Measurement solution for total VOC via FTIR
of the gas stream. FID analyser cannot indicate the relative abundances of different organic species in a gas stream and often have widely different responses for different gases. However, they are taken as the standard reference method for Total VOC emission ...
By Protea Limited based in Middlewich, UNITED KINGDOM.
-
Precision moisture analysis instruments for measuring free and bound moisture in gypsum
If you work with gypsum, you know how crucial moisture measurement is to making a high-quality product. Computrac® understands; that’s why Computrac has been the de facto industry standard for moisture measurement in gypsum for decades. The Computrac MAX® 4000XL will provide accurate results ...
By AMETEK Brookfield based in Middleboro, MASSACHUSETTS (USA).
-
Curiox Resources for Laminar Wash
This is where you can learn about various applications that benefit from Laminar Wash technology and links to useful ...
By Curiox Biosystems Pte Ltd based in Singapore, SINGAPORE.
-
Precision moisture analysis instruments for rapid solids testing for pulp and paper
Durable, reliable analysis for black liquor. Black liquor is a difficult substance to work with. It’s caustic, it’s toxic, and it emits poisonous gases such as hydrogen sulfide. But the efficient use of black liquor is critical to the profitable operation of any pulp and paper mill. In order to use black liquor efficiently, you need to test it for solids. Make sure your solids analyzer is up to the ...
By AMETEK Brookfield based in Middleboro, MASSACHUSETTS (USA).
-
Precision moisture analysis instruments for rapid moisture analysis for foods
Optimize processes and deliver consistent quality. Maybe you’re serious about snacks. Or nuts about nuts. Maybe you’re all about oils. Or perhaps baked goods are your bread and butter. Whatever the case, you know that accurate moisture control is critical to the success of your food products. The Computrac® family of moisture analyzers will enable you to quickly obtain reliable, repeatable moisture content results, independent of operator ...
By AMETEK Brookfield based in Middleboro, MASSACHUSETTS (USA).
-
Precision moisture analysis instruments for rapid solids analysis for paints and coatings
Safely analyze solvent- and non-solvent-based coatings. Your customers rely on your paints and coatings to keep their assets safe from their environments. You can rely on Computrac® to provide accurate, reliable readings in minutes on solids and ash content for your products. Computrac Moisture, Solids and Ash analyzers can be used in ASTM method D7323-06, and can be correlated to other test methods, including D2369, and D5095. Further, Computrac® is the ONLY rapid loss-on-drying analyzer with Nitrogen ...
By AMETEK Brookfield based in Middleboro, MASSACHUSETTS (USA).
-
Precision moisture analysis instruments for moisture and solids testing for batteries
Quickly test cathode powders and other advanced materials: In batteries, it has never been more critical to get the best quality product to market. Whether intended for an electric car, a smartphone, or a smoke detector, the quality of any battery will depend on how accurately its moisture content is controlled. Computrac can help. Computrac can quickly provide moisture-specific and total solids content results in a manner that does not depend on operator technique. In addition to instruments based on the ...
By AMETEK Brookfield based in Middleboro, MASSACHUSETTS (USA).
-
Precision moisture analysis instruments for measuring moisture, solids and ash in chemical production
If you make a living on chemical reactions, you know that accurate moisture, solids and ash content control is critical to a successful reaction. Whether your product is organic or inorganic, flammable or flame-retardant, exotic or commoditized, Computrac has an instrument that will help you make your process more productive, more reliable, and more profitable. The Computrac line of instruments can provide primary measurements for solids content, ash content, total volatile content, and water-specific moisture ...
By AMETEK Brookfield based in Middleboro, MASSACHUSETTS (USA).
-
Particulate monitoring for continuous emissions
With the advent of specific process emission limits being defined, continuous particulate monitoring has become a regulatory requirement for many industries. smoke stack #1Particulate monitoring requires the measurement of the mass concentration of particulate matter in stack emissions to atmosphere. There is no known method of continuously measuring particulate concentration by direct measurement and therefore, all continuous particulate measurement methods are inferential. Each method involves the ...
By Dynoptic Systems Ltd - ACOEM Group based in Banbury, UNITED KINGDOM.
-
Measurement solution for measuring total VOC via FTIR
Current Total VOC Measurements The most common, and current standard, method for measuring Total Volatile Organic Compounds (VOC) is the use of a Flamed Ionisation Detector (FID). This gives a representative value of the total carbon content of a gas stream, as the FID cannot tell which specific organic ...
By Protea Limited based in Middlewich, UNITED KINGDOM.
-
Microbial testing for metalworking fluids industry
Microbial Contamination Results in Less than 5 minutes! Microbial growth in metalworking fluids presents a major problem. Storage tanks, recirculation lines, filters, and other equipment can become fouled through microbial proliferation and metabolic activity, which results in a myriad of problems. These problems include compromised product quality from microbially influenced corrosion (MIC), equipment and filter plugging, and health risks from bioaerosols. The best solution to these problems is early detection ...
By LuminUltra Technologies Ltd. based in Fredericton, NEW BRUNSWICK (CANADA).
-
Super ActivO - Ozone Generators for Residual Ozone
This Super ActivO application note answers the question as to why the ‘slight smell of ozone’ may sometimes be present after the Super ActivO has completed its operation which includes ozone ...
By Ecozone Technologies Ltd. based in Kadima, ISRAEL.
-
Sitelab Hydrocarbon Fingerprinting & Forensic Analysis using UVF-Trilogy
Sitelab's UVF-Trilogy analyzer, model no. 7200-004-FNGP, is used to fingerprint and identify the age or type of contamination on your site at a fraction of the cost compared to conventional laboratory forensic analysis. The equipment is easy to use and samples take just a few minutes to analyze. Test samples for GRO, EDRO, PAHs and TPH-Oil using the four UV modules included with the instrument. ...
By Sitelab Corporation based in West Newbury, MASSACHUSETTS (USA).
-
Industrial monitoring solutions for the opacity and dust monitoring areas
There is a requirement for many small boiler operators to monitor Opacity to determine the smoke density emitted from the boiler. On small boilers we recommend the DCEM 1001 Opacity monitor; this simple, low cost monitor has high efficiency air purges use compressed air to ensure that optical surfaces are virtually free of dust or debris contamination. This ensures minimal maintenance is required on the ...
By Codel - a Forbes Marshall company based in Bakewell, UNITED KINGDOM.
-
Air Quality Monitoring Equipment for Industry
Signal manufacture a wide range of Air Quality Monitoring equipment, from reference method integrated systems down to battery powered indicative ...
By Signal Group Ltd based in Camberley, UNITED KINGDOM.
-
Precision moisture analysis instruments for fast, accurate solids analysis for wastewater
Computrac moisture, solids and ash analyzers are able to quickly and easily determine solids content of cakes, slurries and sludge samples for the wastewater, hazardous waste and landfill industries. Identifying the optimal solids content of these byproducts of the treatment process can provide significant cost savings on chemical additives, haulage and incineration. Computrac analyzers are easy to use and their rugged and reliable design means that you’ll get accurate results whether they’re in the ...
By AMETEK Brookfield based in Middleboro, MASSACHUSETTS (USA).
-
Pretreatment solution for heavy metal and harmful elements in rice
In Dec, 2013, cadmium rice appeared again on the market. In Hongkong, 3 kinds of rice was found out of limits in cadmium, a kind of heavy metal which is able to cause kidney damage. However, in late May, 2013, the spot check by Guangdong Food and Drug Administration has just found there were 120 batches of cadmium-out-of-limits rice, which came from 8 cities in Hunan provinces. Back to Feb, 2011 Professor Pan reported that early in 2007, he had a survey on rice from the markets of six areas in China, which showed ...
By PreeKem Scientific Instruments Co.,Ltd. based in Shanghai, CHINA.
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you