Only show results available in Virginia? Ok

sf6 measuring Applications

  • Premium

    SF6 Leak Detection

    Monitoring Sulfur Hexafluoride (SF6) in the Power Utility Industry. Monitoring Sulfur Hexafluoride in the Power Utility Industry The SF6 Leak Detector 3434i from LumaSense offers an unmatched combination of performance and convenience. Based on the company’s Photoacoustic Spectroscopy (PAS) technology, the system offers highly accurate, reliable and stable quantitative gas analysis and detection. The growing environmental requirements and pressures regarding the use of SF6 make LumaSense’s system a coveted tool designed for everyday use. The system is able to measure the total concentration of the SF6 gas in an enclosed area, where the switchgear (or other SF6 filled equipment) is tested. Although only the total amount leaked is required by today’s standards, it is also advantageous to be able to pin point the leaks. This makes it easier to improve the integrity of the equipment. The SF6 Leak Detector system meets all of requirements for confined area such as substation Monitoring.

    By LumaSense Technologies, Inc. based in Santa Clara, CALIFORNIA (USA).

  • Premium

    Testing Fume Hood Flow Dynamics using SF6 as a Tracer Gas

    A safe laboratory environment requires an effective method for clearing toxic material from fume hoods. Since all handling of toxic materials is completed in these hoods, it is critical to have a procedure to evaluate their operation to assure adequate protection for laboratory workers. The InfraRan Specific Vapor Analyzer, factory calibrated for SF6, is an ideal instrument for measuring fume hood efficiency in accordance with ASHRAE and other standards. Manufacturers identify the flow dynamics (factors that affect air flow in the hood and performance with air) using the ratings AM (as manufactured), AI (as installed), and AU (as used). A fume hood evaluation conducted under its operational environment is critical, as these tests will indicate any installation shortcomings as well as direct workers in proper laboratory hood techniques.

    By Spectro Scientific based in Chelmsford, MASSACHUSETTS (USA).

  • Premium

    Fluoride emissions monitoring in aluminum smelters

    Production of aluminum from its ores at aluminum smelters results in carbon dioxide CO2, carbon monoxide CO, sulfur dioxide SO2, and hydrogen fluoride HF gas emissions during the electrolytic process phase to the atmosphere. The gas emissions need to be monitored. Typically the smelters have emission limit values (ELVs) for sulfur dioxide and hydrogen fluoride emissions. These emissions should be measured accurately and with good precision, to ensure the smelter does not exceed its emission limit values. In addition several fluoride compounds may be produced in the electrolytic bath in the event of an oxygen shortage. These compounds include carbon tetrafluoride CF4, hexafluoroethane C2F6, sulfur hexafluoride SF6, and silicon tetrafluoride SiF4.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you