Only show results available in Virginia? Ok

stack measurement Applications

  • Premium

    Portable Stack Monitoring

    Many industries are required to measure stack emissions of toxic gases periodically, but not continuously. Extractive wet chemical methods currently used are slow, labor intensive and expensive. A single GasFinderFC can perform stack monitoring requirements for a specific gas, quickly, easily and accurately.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Stack Testing for the Aluminum Industry

    ALUMINUM INDUSTRY: Performed a range of test measurements required by the promulgation of the Secondary Aluminum MACT standards. Testing included measurements of Hazardous Air Pollutants for establishing Area vs. Major Source Determinations, as well as dioxin/furan compounds associated with chlorine emissions from fluxing operations.

    By AirSource Technologies, Inc. based in Shawnee, KANSAS (USA).

  • Premium

    Gas monitoring instruments and systems for stack testing

    Several EU directives and national laws in European countries set requirements for continuous monitoring of flue gas emissions at power plants. Further requirements are set on the quality assurance of the installed measurement systems at the plants. The relevant standard in this regard is EN 14181:2004, the quality assurance of automated measuring systems. The standard dictates how to determine that the measurement systems installed for continuous emissions monitoring at a plant operate according to the...

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Continuous Metals Stack Monitor (CEMs)

    Cooper Environmental's Xact® 640 has the unique ability to generate high time resolution metals measurement in stacks. This unique capability has the potential to qualify as a substitution for the combination of a Hg/ PM CEMs application as well as the potential for a pollution control system feedback loop that could result in the reduction of pollution control consumables. Our systems have been site certified for compliance measurements at hazardous waste incinerator and secondary lead smelter sites.

    By Cooper Environmental Services based in Beaverton, OREGON (USA).

  • Premium

    Temperature measurement and control devices for cement industry

    TTEC provides Temperature Measurement reliability for the Cement, Concrete & Construction Aggregates Industry. TTEC products provide the accuracy & stability that allow our cement industry customers to achieve the Batch Consistency & High Quality they require. TTEC Series 3000 Thermocouples provide high accuracy for KILN Temperatures to 2700°F (1482°C). TTEC...

    By Thermocouple Technology, LLC (TTEC) based in Quakertown, PENNSYLVANIA (USA).

  • Premium

    Gas monitoring instruments and systems for stack testing according to EPA test method 320

    The United States Environmental Protection Agency (EPA) has two stack testing methods for FTIR gas analyzers. Method 320 is an FTIR method for measuring wide range of organic and inorganic pollutants. Method 321 is a specific version for measuring hydrogen chloride HCl at cement kilns producing Portland cement. These methods define a quality assurance and control processes for verifying the accuracy of the results. The requirements for analytical equipment and software are defined on 40 CFR Part 60 Appendix B...

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Monitoring solutions for the flow monitoring areas

    Many large combustion plants are now required to monitor mass emissions of major pollutants and to do so requires an accurate measurement of stack gas velocity. The VCEM 5100 is certified to EN 15267 part 3 QAL 1 for all industrial processes including waste incineration. It has several key advantages, firstly the sensors optics are not in contact with the hot and dusty environment, the VCEM 5100 can monitor gases at temperatures exceeding 10000C and the analyser requires minimal maintenance. The VCEM 5100 can...

    By Codel International Ltd based in Bakewell, UNITED KINGDOM.

  • Premium

    Process instrumentation and analytics solutions for environmental monitoring industry

    From monitoring impurities in vents, stacks, air or water to point source or area monitoring, automatic and on-line measurement is an important tool. This type of measurement will detect, quantify and assist in reducing emissions. Siemens analytical products are utilized for many of these measurements.

    By Siemens Industry, Inc. - Process Analytics based in Houston, TEXAS (USA).

  • Premium

    Gas Detection Solutions for Carbon Fiber Manufacturing Industry

    The carbon fiber manufacturing industry requires a unique process control solution that conventional gas detection technology lacks. Boreal Laser’s line-of-sight laser based gas detection system is the perfect fit for measuring HF in various pan oven applications and stack emissions monitoring . Whether you are looking for gas detection solutions for safety, environmental or process control needs Boreal Laser has you covered.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Premium

    Marine monitoring solutions for the SO2/CO2/NOx monitoring

    Process control of a SO2 scrubber on a ship is a challenge due to wet and corrosive gases. In such environment, extractive gas sampling systems require high levels of maintenance in order to operate correctly. OPSIS monitoring system solves this by using an optical, non-contact, cross-duct technique. A light beam is sent across the duct or stack to be measured, and the captured light is sent through an optical fibre cable to an analyser. The analyser measures SO2, CO2 and NOx concentrations using UV and IR...

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    High quality gas sensor solutions for landfill

    State-of-the-art systems enabling easy monitoring of CO2 and CH4 gases. Capped Landfill Sites produce a range of gases, mostly methane and carbon dioxide. Legislation requires that these gases are safely removed from beneath the cap to avoid a physical explosion due to the build-up of pressure beneath the cap. Safe disposal usually entails burning such as flare stacks, internal combustion engines or by processing to produce Methane gas fuel. For large sites with access to power distribution infrastructure...

    By Edinburgh Sensors Ltd based in Livingston, UNITED KINGDOM.

  • Particulate monitoring for continuous emissions

    With the advent of specific process emission limits being defined, continuous particulate monitoring has become a regulatory requirement for many industries. smoke stack #1Particulate monitoring requires the measurement of the mass concentration of particulate matter in stack emissions to atmosphere. There is no known method of continuously measuring particulate concentration by direct measurement and therefore, all continuous particulate measurement methods are inferential. Each method involves the measurement...

    By DynOptic Systems Ltd based in Brackley, UNITED KINGDOM.

  • Integrated real-time gas analysis solution for emissions industry

    Pollutant emissions from industrial smoke stacks are a major national concern due to both health concerns and climate change. As a consequence, there are at least tens of gas analyzer manufacturers in the U.S. alone that compete in that market and have done so for years. What CIC Photonics brings to that competitive field is its expertise derived from its Combustion Efficiency Solution and its high performance IRGAS Systems. The IRGAS-CEM provides real-time and simultaneous measurements of the multitude of...

    By CIC Photonics, Inc. based in Albuquerque, NEW MEXICO (USA).

  • Fugitive emissions monitoring on industrial sites

    The real-time monitoring of odorous gases or more classical pollutants emitted by industrial sites (wastewater treatment plants, refineries, landfills, etc.) appears nowadays as a requirement, in order to optimize the site process and operations, or communicate towards the neighborhoods and local public bodies. While emissions can be measured directly at the source (in the stack, exhaust, etc.), ambient air measurement all around the sites provides a better accuracy and anticipate pollution episodes. This is why...

    By ENVEA Cairpol (ex Environnement S.A) based in POISSY Cedex, FRANCE.

  • Opacity monitoring for continuous emissions

    The history of air pollution regulation dates back as far as the 13th century when in 1273, Edward I (Longshanks) of England prohibited the burning of sea coal in London. The smoke produced by its combustion was considered detrimental to human health. By the late 19th and early 20th centuries, regulations were being passed that sought to control air pollution predominantly for smoke and odour control. Traditionally, regulators were concerned with the visual impact of the discharge from a stack or chimney. Therefore...

    By DynOptic Systems Ltd based in Brackley, UNITED KINGDOM.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you