    Portable Stack Monitoring

    Many industries are required to measure stack emissions of toxic gases periodically, but not continuously. Extractive wet chemical methods currently used are slow, labor intensive and expensive. A single GasFinderFC can perform stack monitoring requirements for a specific gas, quickly, easily and accurately.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Stack Testing for Power Generation Plants

    POWER GENERATION INDUSTRY: Conducted detailed measurements of volumetric flow, oxygen, and carbon dioxide levels in huge main ducts in the Economizer Outlet, Air Heater Inlet, and Exhaust Stack locations in order to evaluate overall plant and control system performance

    By AirSource Technologies, Inc. based in Shawnee, KANSAS (USA).

  • Stack Testing for the Aluminum Industry

    ALUMINUM INDUSTRY: Performed a range of test measurements required by the promulgation of the Secondary Aluminum MACT standards. Testing included measurements of Hazardous Air Pollutants for establishing Area vs. Major Source Determinations, as well as dioxin/furan compounds associated with chlorine emissions from fluxing operations.

    By AirSource Technologies, Inc. based in Shawnee, KANSAS (USA).

  • Premium

    Gas monitoring instruments and systems for stack testing

    Several EU directives and national laws in European countries set requirements for continuous monitoring of flue gas emissions at power plants. Further requirements are set on the quality assurance of the installed measurement systems at the plants. The relevant standard in this regard is EN 14181:2004, the quality assurance of automated measuring systems. The standard dictates how to determine that the measurement systems installed for continuous emissions monitoring at a plant operate according to the directives and regulations set. Two major parts of this on-going quality assurance cycle are the QAL2 and AST procedures. A test laboratory performs tests on the systems on-site, and determines whether the systems fulfill the set requirements or not.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Continuous Metals Stack Monitor (CEMs)

    Cooper Environmental's Xact® 640 has the unique ability to generate high time resolution metals measurement in stacks. This unique capability has the potential to qualify as a substitution for the combination of a Hg/ PM CEMs application as well as the potential for a pollution control system feedback loop that could result in the reduction of pollution control consumables. Our systems have been site certified for compliance measurements at hazardous waste incinerator and secondary lead smelter sites.

    By Cooper Environmental based in Beaverton, OREGON (USA).

  • Premium

    Gas monitoring instruments and systems for stack testing according to EPA test method 320

    The United States Environmental Protection Agency (EPA) has two stack testing methods for FTIR gas analyzers. Method 320 is an FTIR method for measuring wide range of organic and inorganic pollutants. Method 321 is a specific version for measuring hydrogen chloride HCl at cement kilns producing Portland cement. These methods define a quality assurance and control processes for verifying the accuracy of the results. The requirements for analytical equipment and software are defined on 40 CFR Part 60 Appendix B Performance Specification 15. Gasmet™ Gas Analyzers and Calcmet™ software have been designed to take the requirements of the performance specification into account.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Gas Detection Solutions for Carbon Fiber Manufacturing Industry

    The carbon fiber manufacturing industry requires a unique process control solution that conventional gas detection technology lacks. Boreal Laser’s line-of-sight laser based gas detection system is the perfect fit for measuring HF in various pan oven applications and stack emissions monitoring . Whether you are looking for gas detection solutions for safety, environmental or process control needs Boreal Laser has you covered.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Biogas monitoring

    meet governmental regulations, it is important to accurately monitor methane gas production, removal, venting, and burning. Knowledge of both methane flow and temperature at the flare stack can define when CH4 is being emitted to the atmosphere. The DX99 FlexPower™ Nodes can be installed in EX area with a Zone 0 ATEX certification. Use the analogue input to determine methane production levels and flow and use the thermocouple model to measure the temperature of a vent to verify the continuous combustion of methane.

    By Banner Engineering Corp. based in Diegem, BELGIUM.

  • Premium

    High quality gas sensor solutions for landfill

    State-of-the-art systems enabling easy monitoring of CO2 and CH4 gases. Capped Landfill Sites produce a range of gases, mostly methane and carbon dioxide. Legislation requires that these gases are safely removed from beneath the cap to avoid a physical explosion due to the build-up of pressure beneath the cap. Safe disposal usually entails burning such as flare stacks, internal combustion engines or by processing to produce Methane gas fuel. For large sites with access to power distribution infrastructure internal combustion engines are used to generate electricity which is fed into the local electricity grid. All of the above safe disposal process require the measurement of the Methane content (and in many cases the CO2 concentration). Edinburgh Sensors provide gas sensors for both Methane and CO2 that can be integrated into landfill gas processing systems enabling easy monitoring of these gases.

    By Edinburgh Instruments Ltd based in Livingston, UNITED KINGDOM.

  • Emissions testing for industrial boilers and burners

    Industrial boilers and burners have their own unique characteristics. When an unexpectedly high CO is detected, the Testo 350 will automatically adjust to the situation, keeping the sensor protected at all times. Don`t worry about climbing and removing the probe from the stack, just hit the fresh air button. The measurements of O2, CO, NO and SO2, combined with automatic calculations (CO2, efficiency, excess air), provide fast tuning solutions. The 350`s compact design is better for working on a platform or small space. The automatic zero pressure measurement is ideal to monitor flow or draft induction. With a pitot tube you can quickly measure velocity and determine mass flow even during long term testing. The Testo 350 makes reporting in lbs/hour easy!

    By Testo Inc. based in Sparta, NEW JERSEY (USA).

  • Integrated real-time gas analysis solution for emissions industry

    Pollutant emissions from industrial smoke stacks are a major national concern due to both health concerns and climate change. As a consequence, there are at least tens of gas analyzer manufacturers in the U.S. alone that compete in that market and have done so for years. What CIC Photonics brings to that competitive field is its expertise derived from its Combustion Efficiency Solution and its high performance IRGAS Systems. The IRGAS-CEM provides real-time and simultaneous measurements of the multitude of toxic combustion products, including CO, CO2, NOx, SOx, CH4, CxHy, H2S, etc. The EP-IRGAS-SPA is also applicable for fast time responses.

    By CIC Photonics, Inc. based in Albuquerque, NEW MEXICO (USA).

  • Particulate monitoring for continuous emissions

    With the advent of specific process emission limits being defined, continuous particulate monitoring has become a regulatory requirement for many industries. smoke stack #1Particulate monitoring requires the measurement of the mass concentration of particulate matter in stack emissions to atmosphere. There is no known method of continuously measuring particulate concentration by direct measurement and therefore, all continuous particulate measurement methods are inferential. Each method involves the measurement of a parameter related to particulate concentration and then requires a calibration to be determined to convert the measured value into one of particulate mass concentration.

    By DynOptic Systems Ltd based in Brackley, UNITED KINGDOM.

  • Opacity monitoring for continuous emissions

    The history of air pollution regulation dates back as far as the 13th century when in 1273, Edward I (Longshanks) of England prohibited the burning of sea coal in London. The smoke produced by its combustion was considered detrimental to human health. By the late 19th and early 20th centuries, regulations were being passed that sought to control air pollution predominantly for smoke and odour control. Traditionally, regulators were concerned with the visual impact of the discharge from a stack or chimney. Therefore, emission limits were expressed in terms of colour or opacity. Modern methods for opacity measurement still use the darkness of the stack gases to measure the amount of smoke or dust emitted within the exhaust gases.