Only show results available in Virginia? Ok

sulfur analysis Applications

  • Premium

    Analysis of H2S, Mercaptans and/or THT in natural gas with energyMEDOR

    Context & Challenges How to analyze H2S, mercaptans and/or THT for detecting the odor of the gas with the ability to have total organic sulfur calculation in a metering station?

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    SF6 Leak Detection

    Monitoring Sulfur Hexafluoride (SF6) in the Power Utility Industry. Monitoring Sulfur Hexafluoride in the Power Utility Industry The SF6 Leak Detector 3434i from LumaSense offers an unmatched combination of performance and convenience. Based on the company’s Photoacoustic Spectroscopy (PAS) technology, the system offers highly accurate, reliable and stable quantitative gas analysis and detection. The growing environmental requirements and pressures regarding the use of SF6 make LumaSense’s system a coveted tool designed for everyday use. The system is able to measure the total concentration of the SF6 gas in an enclosed area, where the switchgear (or other SF6 filled equipment) is tested. Although only the total amount leaked is required by today’s standards, it is also advantageous to be able to pin point the leaks. This makes it easier to improve the integrity of the equipment. The SF6 Leak Detector system meets all of requirements for confined area such as substation Monitoring.

    By LumaSense Technologies, Inc. based in Santa Clara, CALIFORNIA (USA).

  • Saran Bag application

    Title : Preliminary Sampling Methodology and Analytical Procedures for Ambient Sulfur Hexafluoride, Corporate Author : ARMY MEDICAL ENVIRONMENTAL ENGINEERING RESEARCH UNIT EDGEWOOD ARSENAL MD Personal Author(s) : Luckan,Susan K. ; Cooper,William J. Report Date : JAN 1973 Pagination or Media Count : 23 Abstract : A preliminary evaluation of techniques of sampling and gas chromatographic analysis for low levels of sulfur hexafluoride was conducted to determine the most feasible method for available equipment. Using a Tracor MT-150 gas chromatograph equipped with Nickel 63 electron capture detector and polarized dc voltable, it was possible to detect sulfur hexafluoride at a concentration of 0.06 ppb with a 5A molecular sieve column and nitrogen carrier gas, without preconcentration of the sample. Also, a comparison of glass and Saran sampling materials proved that no detectable loss of the tracer gas resulted with the Saran bags (between 6 ppm and 0.06 ppb SF6

    By Analytical Specialties, Inc. based in Elburn, ILLINOIS (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you