Only show results available in Virginia? Ok

temperature measurement product Applications

  • Remote temperature monitoring

    To abide local regulations, and ensure efficient and effective composting, the temperatures of the windrows must be measured and logged constantly. With accurate temperature measurements, you can determine the optimum time to turn the windrows for quicker compost production. Time consuming and error prone manual data collection is eliminated using a SureCross FlexPower Node equipped with three thermocouples to automatically monitor the temperature at three depths within a compost windrow. Temperature sensor readings are wirelessly transmitted back to the Gateway or host system for data collection, analysis, and logging. Because the temperatures are measured and recorded continuously, the composting rows can be turned as soon as the temperature reaches the ideal point. Continuously monitoring the temperature will also provide an early warning to potential fire hazards by notifying personnel when temperatures exceed recommended ranges, thereby preserving the product.

    By Banner Engineering Corp. based in Diegem, BELGIUM.

  • Chlorine Level Measure Meter

    External Liquid Level Gauge for Chlorine tank measure / no need drilling the tank. Non intrusive Measure range: 20M Power supply: DC 24V Accuracy: 0.1% Power: 10W Signal output: 4-20mA Communication Protocols: RS-485 HART MODBUS Environment temperature: -20-70 degree Liquid temperature: -50-100 degree Explosion proof class: ExdIICT6 Protection class: IP67 Jilina Lee Skype: jilina1986 Cell: 0086 15809274235 Sonar Technology, External liquid indicator uses the principle of sonar ranging collecting the sonar signal by the special probe fixed outer wall of the tank. Pioneering the Two-Wire System, Overcoming various technical dilemmas, two-wire system External liquid level indicator has been successfully developed. Easily Installation Trial run and Maintenance, No effect on production, No need clean the tank when installing, trial running and Maintaining. Auto-diagnosed and collation, Accuracy is 0.1%

  • Premium

    Oxygen monitoring from aerobic and anaerobic for biodegradation tests

    Biodegradation tests involve testing samples in response to various parameters: dilution, nutrient addition, pH, temperature, and others. The pattern of oxygen uptake in aerobic tests; nitrogen gas production in anoxic denitrification tests; methane production in methanogenic tests; hydrogen production during glycolysis; and carbon dioxide production during fermentation reactions gives a measure of the rate and extent of biodegradation of the organic constituents of the test sample.

    By Respirometer Systems and Applications, LLC based in Springdale, ARKANSAS (USA).

  • Premium

    Gas Sensing for Gasification

    Syngas (short for synthetic gas) can be burnt and used as a fuel source, the main constituents of syngas are Carbon Monoxide (CO) and Hydrogen (H), which amount for around 85% of Syngas, and it is produced by a process called Gasification. Gasification starts with a base material which can originate from a wide variety of materials for example wood chips and pellets, plastics, municipal solid waste, sewage, waste crops, and fossil fuels such as coal. During Gasification the base material is reacted at high temperature without combustion with controlled amounts of oxygen (O) or steam. The composition of the base material combined with the amount of oxygen and heat used in the process affects the composition of the resultant SynGas, in which the CO can vary between around 20 and 60%. In addition, large amounts of H and CO are also formed. The measurement of CO is therefore an important feature in the production of SynGas.

    By Edinburgh Instruments Ltd based in Livingston, UNITED KINGDOM.

  • Cement & Lime Industry Emissions Analysis & Monitoring

    A key issue in the measurement of the products of combustion in Cement and Lime industries is the high levels of particulates. The Procal 2000 in situ analyser`s heated probe option is especially suited to this industry as it efficiently deals with variations in process temperature, keeping the probe above the sample dew point and safe from corrosive condensate.

    By Procal - Parker Hannifin Corp based in Peterborough, UNITED KINGDOM.

  • Biogas monitoring

    meet governmental regulations, it is important to accurately monitor methane gas production, removal, venting, and burning. Knowledge of both methane flow and temperature at the flare stack can define when CH4 is being emitted to the atmosphere. The DX99 FlexPower™ Nodes can be installed in EX area with a Zone 0 ATEX certification. Use the analogue input to determine methane production levels and flow and use the thermocouple model to measure the temperature of a vent to verify the continuous combustion of methane.

    By Banner Engineering Corp. based in Diegem, BELGIUM.

  • Gas detection analyzers for coil coating industry

    Coil Coating is a high-temperature solvent vapor monitoring application in which rolls of aluminum or steel are coated with a color finish, oven cured to desired specs and sold to makers of cans, rain gutters, home appliances, building & automotive products and other fabrications. Coil coating requires the use of our PrevEx Flammability Analyzers to monitor the flammability of the solvent vapor driven off during the drying process. PrevEx analyzers accurately measure solvent mixtures and can withstand the temperatures required to prevent sample clogging in coil coating plants.

    By Control Instruments Corporation based in Fairfield, NEW JERSEY (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you