Only show results available in Virginia? Ok

toc determination Applications

  • Premium

    Determination of TOC in stack

    PROBLEM: The industrial chimney's emissions of Volatile Organic Compounds (VOCs) are becoming issues of global importance and to have an accurate knowledge about how to test VOC turns into a strategic issue. VOC emissions are quantified and monitored according to standard EN 12619, using FID analyser which uses hydrogen and other reference gases in pressurized cylinder. Operators must then approach the sampling point, often placed several meters from the ground, climbing chimneys of industrial settlements with instruments and cylinders. Is it possible making this job easier and safer? SOLUTION: Using the Polaris FID analyser produced by Pollution Srl, Italy, it is possible to carry out the VOCs monitoring according to EN 12619 without lifting accessories and heavy weights typically involved with FID analyser. Polaris FID analyser complies with this standard regulation but what is really a breakthrough and cutting-edge, is the unmatched portability and the next generation technology

    By Pollution Analytical Equipment based in Budrio (Bologna), ITALY.

  • TOC Correlation to BOD or COD

    Challenge: Biochemical Oxygen Demand (BOD) and Chemical Oxygen Demand (COD) are traditional parameters analyzed in the laboratory to determine organic matter in water and wastewater. Wastewater facility operators need to have constant data to monitor their discharges and optimize treatment processes (biological treatment, chemical dosing, etc). The requirements of BOD and COD analysis prevent them from being implemented as control parameters, however. The BOD five-day analysis time requirement does not allow an operator to use the data for process optimization and. although COD requires less time than the BOD, its analysis includes the use of hazardous chemicals and has no constant analysis capability.

    By GE Analytical Instruments based in Boulder, COLORADO (USA).

  • Premium

    High quality gas sensor solutions for total organic carbon (TOC)

    Minimising costs through measurement of CO2 concentration. Both water suppliers and water users need to know the quality of the water they are supplying, using and disposing of so as to minimise their costs. One measure of water quality is the organic carbon content (TOC). TOC is measured by oxidising the organic carbon to produce CO2 which is then measured and the value converted into a TOC measurement. Edinburgh Sensors supply sensors to measure the CO2 concentration produced by oxidising the organic carbon in a water sample, allowing the TOC to be calculated. This TOC value determines one measure of how clean the water sample is.

    By Edinburgh Sensors Ltd based in Livingston, UNITED KINGDOM.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you