Only show results available in Virginia? Ok

vapor analyzer Applications

  • Premium

    Water Vapor Permeation Analyzers for Packaging Industry

    For packaging film barriers, the Systech Illinois range of water vapor permeation analyzers offer a wide measurement range with precision temperature, humidity and flow control. These analyzers utilise the Coulometric P2O5 sensor, which is more sensitive and stable than infra-red and does not require calibration. The P2O5 is the primary method for absolute moisture measurement.

    By Systech Instruments Ltd based in Thame, UNITED KINGDOM.

  • Premium

    Oxygen Permeation Analyzers & Water Vapor Permeation Analyzers for Packaging Industry

    Systech Illinois` comprehensive permeation range includes the recently acquired Lyssy and PermMate product lines which offer precision oxygen and water vapor analysis of packaging film barriers.

    By Systech Instruments Ltd based in Thame, UNITED KINGDOM.

  • Gas detection analyzers for coil coating industry

    Coil Coating is a high-temperature solvent vapor monitoring application in which rolls of aluminum or steel are coated with a color finish, oven cured to desired specs and sold to makers of cans, rain gutters, home appliances, building & automotive products and other fabrications. Coil coating requires the use of our PrevEx Flammability Analyzers to monitor the flammability of the solvent vapor driven off during the drying process. PrevEx analyzers accurately measure solvent mixtures and can withstand the temperatures required to prevent sample clogging in coil coating plants.

    By Control Instruments Corporation based in Fairfield, NEW JERSEY (USA).

  • Gas detection analyzers for processing ovens & dryers

    Many industries are involved in coating products with solvent-borne materials and then employing ovens or dryers to remove the solvents from the finished product. The key hazard is an explosion from the build up of solvent vapors in the oven or dryer atmosphere. This buildup could occur by a malfunction in the production process such as: a sudden or improper amount of coating, a change in ventilation controls or excessive speed. In any of these cases, the concentration of flammable vapor has an opportunity to rise above safe levels, creating a potentially explosive mixture of vapor in air.

    By Control Instruments Corporation based in Fairfield, NEW JERSEY (USA).

  • Gas detection analyzers for wastewater treatment industry

    Regulations prohibit facilities from discharging flammable or explosive wastes from their processes into the wastewater collection system. These wastes are not only a fire and explosion hazard but they can also effect the efficient and effective operation of the treatment facility. PrevEx Flammability analyzers are used to continuously monitor the waste stream for flammable gases and vapors. Their unique design and operating technology make them the ideal analyzers for the harsh conditions found in the sewer environment.

    By Control Instruments Corporation based in Fairfield, NEW JERSEY (USA).

  • Premium

    Permeability Testing of Medical and Pharmaceutical Packaging Industry

    The measurement of oxygen and water vapor permeation is often critical in medical and pharmaceutical applications; to prevent contamination, to extend the shelf life and potency of drugs and to ensure powders do not clog. Systech`s permeation analyzers and corresponding software conform to 21CFR Part 11.

    By Systech Instruments Ltd based in Thame, UNITED KINGDOM.

  • Premium

    Gas monitoring instruments and systems for process NOx measurement

    Nitric acid HNO3 is an important intermediate reagent for production of several important end products, such as fertilizers, explosives, dyestuffs/pigments, pesticides, pharmaceuticals, photographic materials, plastics, and synthetic fibers. At nitric acid manufacturing plants, the Gasmet™ FTIR Gas Analyzer can be used to measure several gaseous components from the process stream for purposes of process control. A single system can be used to measure the high levels of nitrogen monoxide NO and nitrogen dioxide NO2, as well as water vapor H2O, nitrous oxide N2O, carbon monoxide CO, carbon dioxide CO2 and ammonia NH3. The fixed installation products for these purposes are the Gasmet™ CEM II measurement system, and the Gasmet™ FCX Gas Analyzers, both of which utilize the FTIR measurement technique for simultaneous multicomponent analysis of the sample gas.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Capabilities of the Adsorbent Tube Injector System (ATIS™)

    The Adsorbent Tube Injector System (ATIS) was developed at Supelco® by R&D Scientists, as a tool to assist in our comprehensive adsorbent research for thermal desorption tubes. The ATIS provides an efficient means of transferring calibration standards in either the gas or liquid phase onto the adsorbent packed tubes. The ATIS employs the technique of flash vaporization to vaporize the sample in a continuous flow of inert gas; the inert gas carries the sample to the tube. The sample pathway of the ATIS is constructed of glass and stainless steel. The calibration standard is injected by a syringe through a replaceable septum in the center of the injection glassware, which is heated. After enough time has elapsed, typically less than five minutes, the tube is removed from the ATIS and analyzed using the appropriate analytical technique for that adsorbent tube.

    By Sigma-Aldrich Co., LLC based in Bellefonte, PENNSYLVANIA (USA).

  • Premium

    Testing Fume Hood Flow Dynamics using SF6 as a Tracer Gas

    A safe laboratory environment requires an effective method for clearing toxic material from fume hoods. Since all handling of toxic materials is completed in these hoods, it is critical to have a procedure to evaluate their operation to assure adequate protection for laboratory workers. The InfraRan Specific Vapor Analyzer, factory calibrated for SF6, is an ideal instrument for measuring fume hood efficiency in accordance with ASHRAE and other standards. Manufacturers identify the flow dynamics (factors that affect air flow in the hood and performance with air) using the ratings AM (as manufactured), AI (as installed), and AU (as used). A fume hood evaluation conducted under its operational environment is critical, as these tests will indicate any installation shortcomings as well as direct workers in proper laboratory hood techniques.

    By Spectro Scientific based in Chelmsford, MASSACHUSETTS (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you