Only show results available in Virginia? Ok

waste sample Applications

  • Premium

    Substitute fuel sampling system

    A critical eye for every sample! Analytical shredding systems for QA work are a fundamental preliminary component in the production of substitute fuels. With primary fuels and finite resources subject to continuous price increases, the significance of substitute fuels continues to rise unabated. For plant operators, this offers first-class potential and attractive prospects for the future. Businesses that buy in their substitute fuel from external suppliers are faced with two key analytical requirements before...

    By Erdwich Zerkleinerungssysteme GmbH based in Igling, GERMANY.

  • Premium

    Determination of inorganic anions in water samples

    Introduction

    The method allows determination of inorganic anions (chloride, nitrite, sulfate, nitrate, fluoride, and phosphate as soluble ortho-phosphate) in samples of natural, potable, and cleaned waste water.

    By Lumex Instruments Group based in Mission, BRITISH COLUMBIA (CANADA).

  • Premium

    Determination of inorganic cations in water samples

    Introduction

    The method allows determination of ammonium, lithium, sodium, potassium, magnesium, calcium, strontium and barium cations in samples of natural, potable, and waste water by the capillary electrophoresis method.

    By Lumex Instruments Group based in Mission, BRITISH COLUMBIA (CANADA).

  • Premium

    Sampling for the water and wastewater industry

    Sampling requirements in the water and waste water treatment industry demand safe and reliable pump control. Many sampling applications require a suction lift. There is no better suction lift than that achieven using a peristaltic oump which lift up to 30 feet. Watson-Marlow pumps are perfect for automatic or manual sampling at the different stages of the treatment process.

    By Watson-Marlow Fluid Technology Group based in Falmouth, UNITED KINGDOM.

  • Stack Testing for VOC Recovery Afterburner Installation

    HAZARDOUS WASTE HANDLING INDUSTRY: Conducted on-site GC speciation of VOC constituents by Method 18 collecting samples continuously around-the-clock in large vacuum canisters in order to demonstrate compliance control of a VOC recovery/afterburner installation

    By AirSource Technologies, Inc. based in Shawnee, KANSAS (USA).

  • Laboratory equipments for fluorine in industrial & construction waste

    Measuring Fluorine in Industrial and Construction Waste using Benchtop NMR MQC Analyser. Processing and recycling of industrial and construction waste often requires measuremetns of fluorine content in the materials. It mostly relates to monitoring potential emission of toxic fluorine gas and optimisation of the waste processing. Our benchtop NMR analyser MQC systems provide a fast, simple and accurate method of measuring fluorine in liquid and dry waste. The NMR technique does not require the use of any...

    By Oxford Instruments plc based in Abingdon, UNITED KINGDOM.

  • X-ray fluorescence XRF analysis for environmental protection and waste management

    To meet the requirements of new regulations and to protect the environment effectively, industries need techniques that enable the analysis of elements at lowest concentration levels. Bruker X-ray fluorescence (XRF) analysis is the most suitable analytical technique for handling different kinds of materials. Bruker’s XRF, ICP-MS, GC, TOF-MS, FT-IR, CBRNE products and applications help you to monitor contaminated land efficiently and quickly, to determine hazardous elements in the air and water, as well...

    By Bruker Corporation based in Billerica, MASSACHUSETTS (USA).

  • Waste water respirometry solutions for toxicity based consents

    Water companies, water authorities or publicly-owned treatment works (POTW) need to have some knowledge of the composition of the wastes they it receive. In addition to testing for ammonia and BOD or COD levels, treatment works can license industrial discharges on the basis of concentrations of some of the known toxic compounds. However, it is recognised that very many non-regulated toxic materials still enter the treatment works and reduce the efficiency of biodegradation, and may cause toxic shock. The way is...

    By Strathkelvin Instruments Ltd. based in North Lanarkshire, UNITED KINGDOM.

  • Waste water respirometry solutions for toxicity tracking

    If toxicity is identified in a mixed sewage entering a treatment works, the problem for the plant manager is to track and identify the source of the toxicity. This can be done by sampling the effluent stream at various points in its length. By working in a logical sequence back up the sewer network the number of samples can be minimised. This type of testing should be rigorously enforced for new product introduction by a waste producer, as well as sampling the effluents directly at source. The samples would be...

    By Strathkelvin Instruments Ltd. based in North Lanarkshire, UNITED KINGDOM.

  • Premium

    Determination of acetic acid (acetate anions) in natural, drinking, and waste water

    Introduction

    The method is used for the determination of acetic acid (as acetate ions) in the samples of natural water, drinking water, and waste water by capillary electrophoresis.

    By Lumex Instruments Group based in Mission, BRITISH COLUMBIA (CANADA).

  • EPR waste minimisation monitoring for wastewater treatment industry

    The EPR regulations have replaced the IPPC regulations and are effective from May 2009 for qualifying companies within the industrial sector and October 2009 within the water sector. They will progressively require industry to minimise waste, reduce product loss and implement improved process control. The legislation will require the operator to self monitor processes and discharges, to demonstrate effective control with particular emphasis on EPR compliance and prevention. The regulating Agency will operate a...

    By Pollution & Process Monitoring Ltd based in Sevenoaks, UNITED KINGDOM.

  • Premium

    RAPID ANALYSIS OF TOTAL MERCURY IN WASTE WATERS AND PROCESS WATERS WITH ELEVATED MERCURY CONTENT USING DIRECT PYROLYSIS TECHNIQUE

    A conventional standard method of total mercury determination in water using atomic absorption spectrometry (AAS) involves preliminary sample digestion that takes from 30 minutes to 8 hours depending on the digestion conditions. The use of a mercury analyzer RA-915M/RA-915+ with Zeeman background correction in combination with PYRO-915+ pyrolysis attachment provides direct determination of mercury in process and waste waters contaminated with mercury without digestion or any other sample preparation stages. The...

    By Lumex Instruments Group based in Mission, BRITISH COLUMBIA (CANADA).

  • Premium

    Determination of phenoxycarboxylic acid herbicides in water using high performance capillary electrophoresys method using Capel systems

    The method allows determination of herbicides classified as phenoxycarboxylic acids, specifically: 2,4-dichloro-- phenoxybutyric acid (2,4-DB), 2,4-dichlorophenoxypropionic acid (2,4-DP, Dichlorprop), 2,4-dichloropheno-- xyacetic acid (2,4-D), and phenoxyacetic acid in samples of natural, potable and treated waste water by capillary electrophoresis. 

    By Lumex Instruments Group based in Mission, BRITISH COLUMBIA (CANADA).

  • Environmental monitoring solutions for the landfill industry

    Since 1982, QED has been the leading supplier of air-powered pumps for groundwater sampling, leachate and condensate management, providing expertise in groundwater monitoring, leachate level control and methane recovery systems and equipment to landfills ranging from small municipal facilities to large industrial and military sites, including the leading national and international solid waste management companies.

    By QED Environmental Systems, Inc. - A Graco Company based in Dexter, MICHIGAN (USA).

  • Independent particle characterization services for environmental industries

    Particle size, particle concentration and other physical characterization analyses are critical to many environmental applications. Regulatory agencies in the environmental sphere demand strict compliance to standards and discharge regulations. Physical testing of samples for parameters such as particle size and concentration can give insight to the process control engineer on how effective and compliant a discharge handling system is operating. Particulate loading from both air emissions and waste water discharge...

    By Particle Technology Labs based in Downers Grove, ILLINOIS (USA).

  • Precision moisture analysis instruments for fast, accurate solids analysis for wastewater

    Computrac moisture, solids and ash analyzers are able to quickly and easily determine solids content of cakes, slurries and sludge samples for the wastewater, hazardous waste and landfill industries. Identifying the optimal solids content of these byproducts of the treatment process can provide significant cost savings on chemical additives, haulage and incineration. Computrac analyzers are easy to use and their rugged and reliable design means that you’ll get accurate results whether they’re in...

    By Arizona Instrument LLC based in Chandler, ARIZONA (USA).

  • Environmental Monitoring

    Environmental monitoring is becoming more important every day in local, national and international policies, showing the environmental awareness demanded by society.

    This fact gives rise to an increase in the amount of legislation that obliges companies to law enforcement. Thus, the necessity of making more pollutants controls means high analysis expenses to the companies, which need to subcontract this service.

    Although applications in this area advance, there is still a clear demand to get new...

    By MicruX Technologies based in Oviedo, SPAIN.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you