Only show results available in Virginia? Ok

water level control Applications

  • Ultrasonic Level Monitoring for Water Bottling Plant Level Control

    Culligan Water installs Greyline SLT32 Level Monitors to control tank levels in their bottling plant in Calgary, Alberta. With non-contacting ultrasonic sensors the SLT32`s control fill and discharge valves in five tanks containing spring water, reverse osmosis water and distilled water.

    By Greyline Instruments Inc. based in Long Sault, ONTARIO (CANADA).

  • Level indicating transmitter for swimming pool level control

    A Surge Tank is used at the Okatokes Rec Centre Swimming Pool to regulate pool level. By monitoring level in a surge tank the non-contacting Greyline LIT25 Level Indicating Transmitter controls makeup water flow through a solenoid valve.

    By Greyline Instruments Inc. based in Long Sault, ONTARIO (CANADA).

  • Measurement and control systems for the Limiting the level - electronically

    A distinction is made between low water (LW) and high water (HW) limiters. Whereas LW limiters are in principle required for the safe operation of a plant in accordance with European regulations, HW limitation (overfill protection) is required only in accordance with TRD 604 for 72-hour operation.

    By IGEMA GmbH based in Münster, GERMANY.

  • Algae control

    Excessive algae growth can throw even the best water treatment processes out of balance. Algae can clog intake screens, fluctuate pH levels, increase chlorine demand, and negatively affect the taste and smell of water. By blocking sunlight within water treatment tanks, you can stop algae growth, reduce chemical usage, and minimize the formation of disinfectant by-products (DBPs). Temperature is better controlled and maintenance associated with algae cleaning is simplified. The results? Better water treatment and...

    By Geomembrane Technologies, an Evoqua brand based in Fredericton, NEW BRUNSWICK (CANADA).

  • Differential level transmitter for VFD pump control & flow measurement

    An Ontario municipality deploys Portable flowmeters to solve flow rate discrepancies between sewage pump station effluent and lagoon influent flowmeters. Faced with suspension of construction permits due to flow rate uncertainty, the Township of North Glengarry called on Greyline Instruments to help troubleshoot two permanently installed flow meters.

    By Greyline Instruments Inc. based in Long Sault, ONTARIO (CANADA).

  • Pump station level controllers for pump staton call outs

    Town operators were plagued by high level alarm call outs at two new sewage lift stations. Read how they used Greyline`s hybrid ultrasonic level controllers with dual sensor capability to put an end to level alarms.

    By Greyline Instruments Inc. based in Long Sault, ONTARIO (CANADA).

  • Measurement and control systems for the controlling the level - electronically

    Discontinuous control is used mainly in smaller steam boilers with low output since the temperature fluctuations in the boiler are fairly great as a result of irregular refilling with water. Continuous control, on the other hand, permits still more economical steam generation with high quality.

    By IGEMA GmbH based in Münster, GERMANY.

  • Water treatment for legionella prevention and control

    Whether you find yourself in a hotel bath room, cruise ship cabin, hospital, office building, industrial plant, greenhouse, car wash facility or your own hot tub, the combination of certain temperature levels, stagnant water and the presence of biofilm in water systems is a potential recipe for disaster: an outbreak of Legionnaires’ disease. An outbreak of Legionnaires’ disease is often the result of negligence, having legal repercussions for responsible parties. Because of its chemical and...

    By Applied Oxidation LLC based in Chattanooga, TENNESSEE (USA).

  • Measurement and control systems for the Indicating the level - mechanically

    Depending on the regulations, a steam boiler must be equipped with one or more direct and/ or indirect level gauges. With direct level gauges, the liquid level can be seen directly through a glass or mica window. The use of a transparent level gauge with background illumination gives operating staff a clear separation between the water and steam zones even when viewed at a relatively long distance. Bicolour level gauges (black and white or green and red) are very suitable for camera transmission to the measuring...

    By IGEMA GmbH based in Münster, GERMANY.

  • Headworks Odor and Corrosion Control Using Hydrogen Peroxide

    Hydrogen Peroxide typically controls odors and corrosion at treatment plant headworks by direct oxidation of hydrogen sulfide (H2S) within the wastewater. In the direct oxidation mode, H2O2 is applied to the wastewater 5-30 minutes prior to the point where the odors are being released, generally as the wastewater line enters the plant boundary. The efficiency of hydrogen peroxide treatment depends upon the available reaction time, the level of iron in the wastewater (reaction catalyst), wastewater pH and...

    By USP Technologies based in Atlanta, GEORGIA (US) (USA).

  • Wastewater solutions for municipal sewer control

    Problem: A significant portion of the operational costs of a conventional municipal wastewater treatment plant employing an aerobic biological treatment unit comes from electricity costs associated with aeration. In many cases, the aeration rates are kept at the maximum level to ensure that the plant’s effluent is in compliance with the regulations. The critical parameter for regulatory purposes and treatment efficiency, BOD, takes 5 days to measure through standard methods providing almost no value to...

    By Real Tech Inc. based in Whitby, ONTARIO (CANADA).

  • Premium

    Waste water treatment plants Air quality control by TRS MEDOR Online Odor Monitoring

    ontext & Challenges Globally, the wastewater treatment is the first public health issue. Urban development leads to urbanization near waste water treatment plant and extension of sewerage network. These aspects induce to an augmentation of sulfur compounds (H2S, mercaptans and sulfides) which are very corrosive, odorant and toxic. To monitor this compounds online CHROMATOTEC® offers high meteorological solutions. Odors are very distinct air contaminants as they generate nuisances. The factors playing a...

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Water treatment

    As a selective oxidizing agent, chlorine dioxide possesses several chemical advantages when compared to the traditional use of chlorine in wastewater treatment. Chlorine dioxide does not hydrolyze in water, and thus it retains its biocidal activity over a broader range of pH. It is also non reactive with ammonia and most nitrogen-containing compounds, and thus effective at lower dose levels than chlorine. It also eliminates phenols, simple cyanides and sulfides by oxidation. Likewise it is effective at odor...

    By Applied Oxidation LLC based in Chattanooga, TENNESSEE (USA).

  • Drinking Water

    Ensuring safe drinking water is a complicated and resource intensive process involving stringent state and federal requirements. Failures in the system are not only costly but can pose serious threats to public health. Pumping tests provide needed data to ensure proper flow and aquifer levels. With DriveConnect technology in place it is possible to significantly minimize expensive lift station drawdown testing.

    Drive‑Chat enabled solutions can reduce costs with automated alerts and remote anywhere...

    By DriveConnect based in Brandon, FLORIDA (USA).

  • Water treatment for water distribution systems

    As a selective oxidizing agent, chlorine dioxide possesses several chemical advantages when compared to the traditional use of chlorine in wastewater treatment. Chlorine dioxide does not hydrolyze in water, and thus it retains its biocidal activity over a broader range of pH. It is also non reactive with ammonia and most nitrogen-containing compounds, and thus effective at lower dose levels than chlorine. It also eliminates phenols, simple cyanides and sulfides by oxidation. Likewise it is effective at odor...

    By Applied Oxidation LLC based in Chattanooga, TENNESSEE (USA).

  • Drinking water analysis for municipalities

    GE Analytical Instruments offers several Sievers TOC Analyzer models designed specifically to simplify monitoring of drinking water treatment plants. Always knowing the TOC levels throughout a water treatment plant, and improving TOC reduction, can help a plant not only control DBPs, but also implement efficient and potentially cost saving treatment processes.

    By GE Analytical Instruments based in Boulder, COLORADO (USA).

  • Potable water treatment

    As a selective oxidizing agent, chlorine dioxide possesses several chemical advantages when compared to the traditional use of chlorine in wastewater treatment. Chlorine dioxide does not hydrolyze in water, and thus it retains its biocidal activity over a broader range of pH. It is also non reactive with ammonia and most nitrogen-containing compounds, and thus effective at lower dose levels than chlorine. It also eliminates phenols, simple cyanides and sulfides by oxidation. Likewise it is effective at odor...

    By Applied Oxidation LLC based in Chattanooga, TENNESSEE (USA).

  • Premium

    Mercury determination in natural, surface, sea, drinking, bottled, mineral, and waste water by cvaas

    Introduction

    Mercury determination in natural, drinking, and waste waters is one of the most popular analyses used for environment pollution and sanitary control. Background concentrations of mercury in natural water are within several ng/l. Maximum national permissible levels for mercury in water lie in the range of 0.16–6 µg/l. For example, the following limits for mercury in drinking water are set, µg/l:
    0.5 – Japan, Russia;
    1 – Argentina,...

    By Lumex Instruments Group based in Mission, BRITISH COLUMBIA (CANADA).

  • Sand and Dust control/stabilisation

    PermeatecDS is a unique polymer technology developed by TAL and is aimed specifically at the control of dust and stabilisation of loose, granular materials. PermeatecDS can be applied to such materials – as an aqueous surface spray – to control dust and provide a hard, durable surface. In addition, it can be mixed directly with loose, granular material to provide a solid block of material. PermeatecDS is a complex acrylate-based polymer system, designed to be dispersed in water, aiding application and improving...

    By Technical Absorbents based in Grimsby, UNITED KINGDOM.

  • Oxygen Generating Systems for Sewage Treatment

    Using Oxygen to Solve Waste Water Problems Lack of oxygen can cause inadequate purification or even anaerobic decomposition, as well as offensive odors. Injecting oxygen into sludge beds &/or piping allows you to: * Reduce nitrogen levels * Meet peak O2 demands * Have a back up to your aeration system * Pre-purify waste water * Control odors * Deter corrosion damage * Meet increased requirements regarding waste water purification

    By Oxygen Generating Systems Intl. (OGSI) based in North Tonawanda, NEW YORK (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you