    Water Testing for Automatic Rinse Tank Controls

    Proper rinsing is one of the most important steps in quality manufacturing or metal finishing. Plenty of low cost, good quality water for rinsing has been available in the past, so rinse water conservation has been largely ignored. Today, this is no longer true. Tap water costs have increased dramatically. Various new regulations are now in effect which limit the allowable volume of wastewater. Others require wastewater treatment. Still other laws tax the amount of water going down the sewer. These factors have all encouraged many manufacturers and platers to invest in automatic rinse tank control systems. Many platers using automatic control systems for the first time are pleased to discover a reduction in water usage of up to 80%.

    By Myron L Company based in Carlsbad, CALIFORNIA (USA).

  • Constant Pressure pump control valves

    For use with water well pumps and booster pumps, the Cycle Stop Valve (CSV) turns any pump into a variable flow, constant pressure system. Working in conjunction with a small pressure tank, the CSV is usually adjusted to the middle of the pressure switch range. IE; 40/60 PSI switch, 50 PSI CSV. The size of the pressure tank determines how much water can be used by the house, before the pressure drops to 40 PSI, and the pressure switch starts the pump. As long as flow rates in and around the house vary from 1 GPM to as much as the pump can produce, the CSV maintains a constant 50 PSI on the system. When there is no more flow required for the house, the CSV allows the little pressure tank to fill to 60 PSI, and the pump is shut off by the pressure switch.

    By Cycle Stop Valves, Inc. based in Lubbock, TEXAS (USA).

  • Ozone/UV systems for Industrial, municipal, and residential wastewater treatment

    In 2004-2005 LIFETECH`s laboratory worked out an advanced oxidation process (AOP) for removal of dioxins and furans (PCDD/F), chlorophenols and other contaminants from the BCD process wastewater. Consequently, our technology was installed and from April 2006 successfully used in the `Spolana-Dioxins` Project at SPOLANA a.s. in Neratovice, Czech Republic, as a part of Special Wastewater Treatment Plant. Our supply consisted of an ozone generator with the output of 5 kg O3/h at 10% w/w ozone concentration, two reaction tanks with mixing systems, a vent ozone destructor, and a control system. The world largest project for removal of PCDD/F was managed by BCD CZ a.s., a subsidiary of Thermal and Chemical Soil Remediation Ltd.

    By Lifetech based in Brno, CZECH REPUBLIC.

  • US Peroxide Rapid Response

    US Peroxide (USP) is uniquely positioned to rapidly respond to your environmental treatment challenges. USP combines experienced applications and equipment field support with a large inventory of storage systems and pumping modules to respond quickly to time sensitive water and wastewater treatment situations. Advantages With considerable inventory of tank and pump systems as well as our partnerships with leading chemical suppliers, USP can mobilize chemicals and equipment quickly to respond to your rapid response needs, often within 24 hours. We offer dosing options are designed to meet all safety requirements and sized to meet your specific process and dosage rates requirements. Our Applications Engineers and Equipment and Engineering Services teams will provide timely and thorough applications assistance and technical support during the entire project. Download the Rapid Response Solutions Brochure (PDF) Sample Applications Examples of where our Rapid Response Program has successfully addressed treatment challenges include the following: Temporary application of hydrogen peroxide as a source of supplemental dissolved oxygen in biological treatment systems during periods of excessive BOD loading Hydrogen peroxide pretreatment of high strength wastewater to reduce toxicity or BOD/COD prior to biological treatment Emergency hydrogen peroxide treatment of lagoons or ponds to control hydrogen sulfide and other odors Shock cleaning of cooling water systems for biofouling and slime control

    By USP Technologies based in Atlanta, GEORGIA (US) (USA).