Only show results available in Virginia? Ok

workplace monitoring instrument Applications

  • Premium

    Measurement solution for ambient air workplace monitoring

    Protea can supply fixed workplace monitoring systems that can measure single or multi-points about the workplace. Specifically designed analytical systems can ensure detection limits down to ppb levels can be achieved for multiple gases with a single instrument. Controlling software can run automatically, providing instantaneous or time-weighted average readings.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Measurement of diacetyl in ambient air to monitor workplace exposure limits.

    The Series 8900 Diacetyl Analyzer provides direct measurement of Diacetyl in ambient air. This instrument is utilized for environmental monitoring and to monitor workplace exposure limits. The Series 8900 Analyzer for Diacetyl employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Diacetyl and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. The Diacetyl is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of methyl bromide in ambient air for monitoring workplace exposure limits in fumigation facilities

    The Series 8900 Methyl Bromide Monitoring System provides an automated, direct measurement of Methyl Bromide in ambient air. This instrument can meet and exceed the requirements for ambient methyl bromide monitoring. It is utilized in fumigation facilities and industrial plants to detect potential worker exposure to methyl bromide, resulting from mechanical failure, human error or product off gassing. Multipoint sampling options allow the analyzer to monitor multiple sample locations for greater coverage.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

    The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Formaldehyde and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Formaldehyde is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

    The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Acrylonitrile and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Acrylonitrile is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of naphthalene in ambient air to monitor workplace exposure limits & at remediation & Superfund sites

    The Series 8900 Naphthalene Analyzer provides direct measurement of Naphthalene in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits and at remediation and Superfund sites. The Series 8900 Naphthalene Analyzer employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Naphthalene and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Naphthalene is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Air sampling & monitoring systems for biomedical, chemical & pharmaceutical industry

    HI-Q Environmental Product Company provides air sampling instrumentation & systems for several niche applications in a number of disciplines in the broad area of `Life Sciences`. In the Biomedical, Chemical, & Pharmaceutical industries, HI-Q has marketed instrumentation for certain applications for many years. Our ambient, in-door breathing level air samplers, commonly known in the industry as `Goose-Neck` or `Giraffe` air samplers have been instrumental in analyzing workplace exposure. HI-Q has also developed accurate pre & post heap filtration stack sampling systems to aid laboratories in inventory control & atmospheric exposure monitoring for chemicals such as Radio Iodine.

    By HI-Q Environmental Products Company based in San Diego, CALIFORNIA (USA).

  • Premium

    Measurement of methyl ethyl ketone, chloroform & carbon tetrachloride in air for remediation & super fund sites

    The Series 8900 Analyzer provides direct measurement of Methyl Ethyl Ketone, Chloroform and Carbon Tetrachloride in ambient air. This instrument is utilized for remediation and Super Fund sites and to monitor workplace exposure limits.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you