Amistad Dam: Identifying Critical Leaks in the Amistad Dam - Case Study
Why was the Amistad dam emptying—and what could be done to solve the problem?
In 1996, the Comision Federal de Electricidad (CFE), the national electric company of Mexico responsible for the Mexican half of the Amistad Dam, contacted AGI. The CFE heard about the capabilities of our instruments to look into the ground, and they were anxious to see if our tools could help them solve their problem: The dam was emptying itself, and thus, failing at flood control, power generation, and recreational use.
BackgroundAmistad Dam is the largest of the storage dams and reservoirs built on the international reach of the Rio Grande River and was dedicated in 1969 by United States President Richard M. Nixon and Mexico President Diaz Ordaz.
The dam is 6.1 miles (10 kilometers) long and stands 254 feet (77.4 meters) above the riverbed; it consists of a concrete gravity spillway section within the river canyon flanked by earth embankments (IBWC). It is owned and operated jointly by the United States and Mexico.
The Problem With Amistad DamEngineers observed holes up to 5m diameter opening in the bottom of the dam that were emptying the dam completely. In places, water was moving in a circular movement, and over time, that circular movement sped up, eventually causing water to disappear into the ground—much like a drain empties water in a bathtub. Engineers uncovered that the water was going downstream, below the dam, and needed to find the path where the water rushed out under the dam.
The Cause Of The LeaksThe dam, which was built on limestone, was subject to fissures. Why? As rainwater falls through the atmosphere, it picks up carbon dioxide and forms a weak carbonic acid—this phenomena is known as acid rain. (It’s interesting to note that carbonic acid is also an ingredient in Coca Cola!)
This acid rain would then find its way through small fractures in the limestone, which causes the limestone to slowly dissolve so that the rock’s fissures and fractures, slowly widen. Eventually, this causes collapse of the hole where water rushed through until a sinkhole appears.
The previously-installed grout curtain in the dam embankment was failing, and the CFE needed to find a solution.
When CFE came to us, they had one question: Where is water breaking through the grout curtain?In order to identify where water was breaking through the grout curtain, we used a 56-electrode Sting/Swift system. We tested three different arrays recorded on the same electrode layout: Dipole-Dipole, Schlumberger, and Wenner.
ProcessThe array of 56 steel electrodes was located at the bottom of the dam in a drained part near the wall. They were placed at five-meter intervals along the survey line. A Swift Smart Electrode cable consisting of four 14-switch segments was connected for this test. The Sting R1 instrument was prepared with two user-defined measurement programs: one for the Schlumberger method and the other for the Wenner method. The measurements were automatically recorded by Sting using these two loaded programs and the built-in Dip-Dip program for a total of three different recordings on the same site using the same electrodes.
The recording times for the three methods were:
-
Dipole-Dipole array: 688 readings in 2 hours, 35 minutes.
-
Wenner array: 495 readings in 1 hour, 56 minutes.
-
Schlumberger array: 426 readings in 1 hour, 39 minutes.
One important note:
This case history took place using our Sting R1 instrument, which has since been retired. We simulated this same data set of 688 readings with our SuperSting R8, which read the data in 12 minutes, as opposed to the approximately two-and-a-half hours it took with the retired Sting to take. That’s 15 times faster!
These three contrasting data sets showed us the following:
-
The Dipole-Dipole array was far superior in terms of resolution and depth penetration.
-
The Wenner had little-to-no ability to resolve the known fracture and basically was useless resolving lateral changes at depth.
-
The Schlumberger, while it didn’t quite have the resolving power of the Dipole-Dipole array, did show some indication of the known fracture. It had a stronger signal to noise ratio than that of the Dipole-Dipole array.
However, the SuperSting instrument is noise insensitive, and it rarely needs to rely on the Schlumberger or the Wenner array for a stronger signal level. There are other implications to now wanting to use Wenner. The Wenner array on top of being less resolving is that it is a single channel array which means that the time to collect the data is slow if you can't utilize all eight channels.
In ConclusionBased on the survey and the data AGI’s instruments were able to provide, the anomalies centered around the local coordinates 565 and 620 were drilled and grouted. The anomaly around 565 is a fracture zone with associated cave and the anomaly at 620 is a cavity. The two systems were injection grouted using 703 cubic meters of a mixture consisting of 50% water, 14% cement and 36% sand.
CFE purchased two instruments, which they began to use routinely to find fractures, which could then be easily grouted as part of the ongoing maintenance process of the dam. The water in the dam is now reported to be raising.
Benefits For Our Client-
Accurate Location Of Fractures & Drilling: It would be very expensive to drill individual holes to locate fractures—unfortunately, this low-tech route is often taken. Most often when you drill, you drill vertically; to find a fracture like this, you have to drill tons of holes, which is both inefficient and cost-prohibitive. The trick is to locate the fractures and drill right into them, which is what AGI’s instruments allow.
-
Savings: AGI’s instruments were the best way for CFE to save money by quickly locating leakage in the dam. Dams require routine maintenance, and the AGI solution—to use instruments to find the actual locations of water leakage instead of guessing and drilling—saves time, labor, and material costs.
You can use this method to locate water in any application—from relief aid, to dam leakage, to any circumstance where you’re looking for water underground.
Products UsedWe have retired the instrument used in this example, the Sting R1. We recommend the SuperSting for surveys like this because it expedites the survey (you can collect and record data up to 15 times faster than with the Sting R1).
-