Glosfume

Case study - Municipal Incinerator (Slovenia)

0

Courtesy of Glosfume

WID and BREF-compliant EU showcase municipal incinerator in Slovenia

During 2008 Glosfume was asked to supply a ceramic filter which could achieve emission levels below WID. Representing the state-of-the-art in high temperature filtration design rated at 70,589 Am3/hr @ 250 °C. The installation complies both Waste Incineration Directive (WID) and BAT Reference note (BREF) compliant and will be used by the EU as a reference plant.

  • Installation date: 2008
  • Location: Republic of Slovenia
  • Filter unit: HTMC12 (400)
  • Filtration area: 912 m2
  • Operating temperature: 250 °C
  • Dry scrubbing: sodium bicarbonate injection/activated carbon injection

Typical emission levels:

  • Particulate: 0.8 mg/Nm3
  • HCl: 6.5 mg/Nm3
  • SO2: 1.8 mg/Nm3
  • NOx: < 200 mg/Nm3
  • HF: 0.4 mg/Nm3
  • Dioxins: 0.05 ng/Nm3
  • Heavy Metals: < 0.5 mg/Nm3

Customer comments

No comments were found for Case study - Municipal Incinerator (Slovenia). Be the first to comment!