Integrated Engineers Inc.

Corrugator Wastewater Case Study Results

- By:

Courtesy of Courtesy of Integrated Engineers Inc.

The corrugating facility installed a DMP system in 1996 to treat the flexographic wastewater consisting of starch from the corrugating operations as well as rinse water from the ink applied to the corrugated boards. The waste treatment system consists of a 500 gallon Collection Tank, (2) 5,000 gallon Reactor Tanks with mixers, a filter press, and a 6,000 gallon Treated Water Tank.