- Home
- Companies
- ERG (Air Pollution Control) Ltd
- Articles
- Gas scrubbing using V-texTM technology ...
Gas scrubbing using V-texTM technology - Case Studies
Feb. 25, 2019
Courtesy ofERG (Air Pollution Control) Ltd
Pharmaceuticals
GlaxoSmithKline
- Removal of Acetic Acid vapour from 1000 ppm to below limit of detection
- Gas flow range 50 to 1000Nm3/hr
- Maintenance free operation since installation in 1997
Optical Fibres
Optical Fibre Manufacturer in Denmark
- Removal of HCl and SiO2
- Five 2 stages units
- Scrub liquor contained up to 5% weight SiO2 with no blockage
Petrochemicals
Major petrochemical refinery in USA
Removal of chlorine 100 ppm, HCl 1500 ppm and SO2 500 ppm in a gasflow of 1000 Nm3/hr
- Temperature of gas 485°C
- 1 % sodium hydroxide scrub liquor
- Removal efficiency 99.9%
Chemicals
Schering Plough
- Stainless steel unit, designed for 200oC and FV to 16 barg to BS5500
- Gas flows ranging from 200 to 3600 Nm³/hr.
- System to start up and achieve full scrubbing efficiency in extremely short time, to cover unexpected bypass requirements
Renewable Energy
- Stainless steel unit designed for 200°C and 3 barg
- Gas flow of 13000 to 17000 Nm3/hr
- Removal of ammonia with an efficiency exceeding 99.5%
- Removal of HCl to less than 1 ppm
- By-product of 12%wt ammonium sulphate
Pharmaceuticals
- HCl scrubbing
- Hastelloy C276 and ECTFE/PTFE
- Pressure and explosion rating certified
- >99.5% HCl removal efficiency, batch scrubbing
Chemicals
- Cl2 scrubbing
- Chlorine scrubbing from process air stream
- NaOCl by-product for sale
Most popular related searches