IWA Publishing

Hybrid filtration method for pre-treatment of stormwater

- By: , ,

Courtesy of Courtesy of IWA Publishing

In this study the hybrid filtration process (combining fibre filter with deep bed dual media filtration) was investigated as pre-treatment to stormwater. This process was investigated in-terms of reduction in turbidity, dissolved organic carbon (DOC), colour, headloss development across the filters, suspended solids removal, organic matter removal, nutrients and heavy matter (such as iron, copper, lead, zinc) removal efficiency. A comparison was made between the hybrid filter with single media (sand) deep bed filter and fibre filter. It was found that the hybrid filtration system successfully removed turbidity (98%), colour (99%), suspended solids (99%), and DOC (55%). The removal efficiency of heavy metal was relatively low as the concentration of heavy metals present in stormwater was low. The removal efficiency of nitrate, nitrite and phosphorous (as orthophosphate) was 27, 35 and 72% respectively. Hybrid filtration processes showed a better reduction of Modified Fouling Index (MFI) value (from 15.500 s/l2 to 9 s/l2) compared with single media sand, anthracite and fibre filter which were 35 s/l2, 13 s/l2and 14 s/l2 respectively when operated at FeCl3 dose of 15 mg/l.

Keywords: dissolved organic carbon, fouling index, head-loss, hybrid filtration, pre-treatment