Industrial process & waste water -MPPE in treatment of tank cleaning-, process- and groundwater case study

0

Problem:

  • Small irregular heavy waste stream (200p ppm, EOCL, BTEX)
  • Big fluctuating waste/ground/surface water stream (5 ppm, EOCL, BTEX)

Solution:

  • MPPE for removing non polar/toxic organic compounds
  • Biotreatment for removing polar and Nitrogen compounds

Specific details

  • Total flow: 25 m3/hr
  • Effluent in Rotterdam harbour
  • Components: BTEX, Chlorinated hydrocarbons
  • N and polar compounds
  • >99% removal

Customer comments

No comments were found for Industrial process & waste water -MPPE in treatment of tank cleaning-, process- and groundwater case study. Be the first to comment!