  • Simultaneous determination of PM fractions, particle number and particle size distribution in high time resolution applying one and the same optical measurement technique

    Abstract The Fidas fine dust monitoring systems comprise an optical aerosol spectrometer, which is characterized by very good instrument characteristics, and utilize a sophisticated approach to convert the measured information on particle number and particle size into mass concentrations. As monitoring of PM requires reliable and quality-controlled performance of the measuring systems, ...


    By Palas GmbH

  • Case study - Designed for generations

    South Dakota facility retrofits advanced process control system Nearly 25 years ago, the consulting engineering firm Banner & Associate, Inc. designed an efficient wastewater treatment facility for a city in S.D. that featured process control, flexibility and treatment efficiency while minimizing operating and maintenance costs. Key to the system was the ...

  • EPA Proposes SNUR for Functionalized Carbon Nanotubes (Generic)

    On October 27, 2016, the U.S. Environmental Protection Agency (EPA) proposed significant new use rules (SNUR) for three chemical substances that were the subject of premanufacture notices (PMN), including functionalized carbon nanotubes (generic). According to the notice, the PMN states that the substance will be used as a thin film for electronic device applications. Based on structure-activity ...


    By Bergeson & Campbell, P.C.

  • New applications of beam–plasma systems for the materials production

    Beam–plasma systems (BPS) are known to be a great prospect for the surface modification of organic and inorganic materials. The present paper considers the plasma–assisted synthesis and deposition from the point of view of the hybrid materials production. Pilot setups in which the above processes occur in the electron–beam plasma (EBP) and combined plasma (CP) are described. The results of the ...


    By Inderscience Publishers

  • Controlling scale in water systems helps prevent legionella

    The Legionella bacterium, Legionella Pneumophila (LP), the fundamental agent of Legionnaire’s Disease, is a water-based organism, which causes infection when inhaled in an aerosol form. Legionnaires' Disease acquired its name in 1976 when an outbreak of pneumonia occurred among persons attending a convention of the American Legion in Philadelphia. Later, the bacterium causing the illness ...

  • New laser-based dust emission monitoring system

    Abstract A new generation of continuous particulate matter concentration monitoring instruments is presented, covering a measuring range of 0 to 1000 mg/m3. The laser-based scattered light instrument gives an improved stability as well as excellent resolution in the low range. This enables high concentration measurement as well as especially low emission monitoring down to 0.01 mg/m3 with a ...


    By Sigrist-Photometer AG

  • Safety Systems Depend on Reliable Field Sensors (Emphasis on Fire and Gas Detectors)

    Abstract Because not all hazards are the same, identifying and quantifying the hazard is the starting point in choosing sensing technology. Not all detectors are the same, and they should be selected according to their ability to detect the hazard. This paper gives a broad summary of technologies that provide users reliable responses to hazardous conditions, that minimise false ...

  • ASHRAE Standard 188P: Prevention of Legionellosis Associated with Building Water Systems

    For Presentation at the AWT 2011 Convention and Exposition  The American Society of Heating, Refrigerating and Air-conditioning Engineers (ASHRAE) has developed a proposed Standard Practice that specifies what is required to prevent legionellosis associated with building water systems. Standard 188P is a “Practices” standard – not a “Design” or ...


    By Phigenics, LLC

  • Method 301 Evaluation of Candidate conditional methods case study

    A new metal emissions measurement and validation system has recently been developed that has the potential to significantly improve our understanding of metal emissions from a wide range of source categories. This system consists of: A continuous emission monitoring system (Xact-CEMS) An instrumental analyzer procedure (Xact-IAP) A sampling and analysis measurement method ...


    By Cooper Environmental

  • Annual simulation of secondary pollution over northern Italy

    A secondary pollution modelling system for simulating airborne dispersion and chemical reactions is applied over a regional scale domain located in the North-West of Italy, where urban and industrial areas are present. It was found an overestimation of NO2 in the urban areas, probably due to an underestimation of the vertical diffusivity; the analysis of O ...


    By Inderscience Publishers

  • GAW Regional Station for Atmospheric Research - 2005 Report

    The aim of the JRC-Ispra station is to monitor the concentration of pollutants in the gas phase, the particulate phase and precipitations, as well as aerosol optical parameters, which can be used for assessing the impact of European policies on air pollution and climate change. Measurements are performed in the framework of international monitoring programs like the Co-operative program for ...


  • GAW Regional Station for Atmospheric Research

    The aim of the JRC-Ispra station is to monitor the concentration of pollutants in the gas phase, the particulate phase and precipitations, as well as aerosol optical parameters, which can be used for assessing the impact of European policies on air pollution and climate change. It is particularly well suited for the participation in international monitoring programs like the Co-operative program ...


  • OTM 17: Determination of Metal Concentrations Using Filters and Solid Sorbents in XRF Analyisis case study

    Eli Lilly and Company (Lilly) operates a waste incineration system located at the Tippecanoe Laboratories in Lafayette, Indiana. This incinerator system includes an Xact multi-metals continuous emissions monitoring system (Xact-CEMS, manufactured by Cooper Environmental Services, LLC) for demonstrating attainment with the Hazardous Waste Combustor MACT for semi-volatile metals, low-volatile ...


    By Cooper Environmental

  • Scrubers with a level head

    The available methods for removing pollutants from a gas stream are numerous, to say the least. A popular method, scrubbers allow users to separate gases and solids by allowing the gas to come into contact with a liquid stream. In the end, the pollutants are washed away in the effluent, and the gas exits the system to be used in later processes or to be released into the atmosphere. For many ...


    By Kimre, Inc.

  • Remote sensing of particulate pollution from space: Have we reached the promised land?

    This paper follows presentation and publication of the Hoff and Christopher 2009 Critical Review and represents an integration of discussants’ views of their paper. The discussants’ comments are organized beginning with a note on the history of satellite sensing, followed with a brief discussion of the strengths and weaknesses of satellite observations relative to air quality management needs. ...

  • Legionella Prevention

    Legionella Pneumophila Legionella has been identified as a major problem in multioccupancy buildings such as hotels, hospitals, hostels, schools, military establishments, nursing homes and office blocks. Worldwide thousands of people become seriously ill or die through infection by this potentially deadly disease. The costs if a buildings water system becomes infected can be substantial not only ...

  • WESPS continue to deliver

    Compliance with the increasingly stringent air pollution regulations of recent years is not the only reason forwardthinking industry leaders are adopting more sophisticated gas cleaning and air pollution control strategies. The desire to achieve higher performance efficiencies, control costs in a competitive marketplace, and stay ahead of the regulatory compliance curve is another driver of ...


    By Beltran Technologies, Inc.

  • Using Hazard Analysis and Critical Control Point Water Management Plans to Prevent Legionellosis

    ABSTRACT Legionellosis is an environmental-source disease caused by Legionella bacteria. Many such diseases are prevented using a scientifically-based risk management process called Hazard Analysis and Critical Control Point (HACCP; pronounced “Hassip”). Water Management Plans based on HACCP have been proven effective for preventing legionellosis. Perspective is given for how ...


    By Phigenics, LLC

  • Cost Savings: Setting and Meeting Targets

    Introduction SC Johnson, family-owned and family-managed for 112 years, has a long history of responsible environmental management.  Sam Johnson, owner and chairman, made history in 1975 by announcing his company's voluntary and unilateral decision to eliminate CFC propellants from its aerosols worldwide--the first company to do so.  It is not surprising that this global manufacturer ...


  • Scientists call manmade chemicals like refrigerant gases a cause of climate change

    A major cause of climate change is the harm that is done to the Earth by man-made chemicals. Whilst chemicals, such as those used to produce day by day items, operate equipment and generally make life easier, are necessary, they present a threat to the environment. Governments around the world have set new regulations to limit the use of substances that contribute to global warming and deplete ...


    By Verisae